Official Distributor
SKU
Weight
0.549 kg
This product is Not Cancellable/Not Returnable
Series AXL-E-ETH-DI
AXL E ETH DI16 M12 6P - Digital module
Axioline E, Digital input device, Ethernet, M12 connector, Digital inputs: 16, 24 V DC, connection technology: 4-conductor, Plastic housing, degree of protection: IP65/IP67
- Connection to Ethernet network using M12 connectors (D-coded)
- Transmission speed of 10 Mbps and 100 Mbps
- Connection of digital sensors using M12connectors (A-coded)
- Diagnostic and status indicators
- Short-circuit and overload protection of the sensor supply
- IP65/IP67 degree of protection
Technical Specifications
Dimensions
Width | 60 mm |
Height | 185 mm |
Depth | 30.5 mm |
Drill hole spacing | 198.5 mm |
Note on dimensions | The height is 212 mm including fixing clips. |
Material specifications
Housing Material | Pocan® |
Color | anthracite |
Ethernet
Number of interfaces | 2 |
No. of channels | 2 |
Connection Method | M12 connector |
Note on the connection method | D-coded |
Number of Positions | 4 |
Transmission Speed | 10/100 Mbps (with auto negotiation) |
Modbus/TCP
Equipment type | Modbus slave (server) |
System-specific protocols | Modbus protocols Modbus/TCP |
Protocols Supported | SNMP v1 |
Protocols Supported | HTTP |
Protocols Supported | TFTP |
Protocols Supported | FTP |
Protocols Supported | BootP |
Protocols Supported | DHCP |
Specification | Modbus application protocol V1.1b |
Digital:
Input name | Digital inputs |
Description of the input | EN 61131-2 types 1 and 3 |
Number of Inputs | 16 |
Cable Length | max. 30 m (to the sensor) |
Connection Method | M12 connector, double occupancy |
Connection technology | 4-conductor |
Input voltage range "0" signal | 0 V ... 5 V DC |
Input voltage range "1" signal | 11 V DC ... 30 V DC |
Nominal input voltage UIN | 24 V DC |
Nominal input current at UIN | typ. 3 mA |
Sensor current per channel | typ. 75 mA (from US) |
Total sensor current | max. 1.2 A (per device) |
Input filter time | < 1000 µs |
Protective circuit | Overload protection, short-circuit protection of sensor supply |
Product properties
Product family | Axioline E |
Type | Stand-Alone |
Special Properties | Plastic housing |
Potentials
Voltage supply US | 24 V DC |
Power supply at US | max. 4 A |
Current consumption from US | typ. 8 mA |
Current consumption from US | max. 1.2 A |
Supply: Module electronics and sensors
Designation | Supply of module electronics and sensors (US) |
Connection Method | M12 connector (T-coded) |
Number of Positions | 4 |
Supply Voltage | 24 V DC |
Supply Voltage Range | 18 V DC ... 31.2 V DC (including all tolerances, including ripple) |
Current consumption | typ. 190 mA ±15 % (at 24 V DC) |
Current consumption | max. 12 A |
Supply: Actuators
Designation | Supply of actuators (UA) for additional devices |
Connection Method | M12 connector (T-coded) |
Number of Positions | 4 |
Supply Voltage | 24 V DC |
Supply Voltage Range | 18 V DC ... 31.2 V DC (including all tolerances, including ripple) |
Current consumption | typ. 3 mA ±15 % (at 24 V DC) |
Current consumption | max. 12 A |
Electrical isolation/isolation of the voltage ranges
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 1) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 2) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/FE | 500 V AC, 50 Hz, 1 min. |
Test voltage: Bus connection (Ethernet 1)/FE | 500 V AC, 50 Hz, 1 min. |
Test voltage: Bus connection (Ethernet 2)/FE | 500 V AC, 50 Hz, 1 min. |
Test voltage: Bus connection (Ethernet 1)/bus connection (Ethernet 2) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, digital inputs) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet 1) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet 2) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V supply (actuator supply)/FE | 500 V AC, 50 Hz, 1 min. |
Connection data
Connection Method | M12 connector |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Degree of Protection | IP65/IP67 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % |
Permissible humidity (storage/transport) | 5 % ... 95 % |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
Mounting Type | Wall mounting |
Accessories
Why Proax for Phoenix Contact 2701533?
Proax is an authorized distributor of Phoenix Contact 2701533 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 2701541 - Axioline E, Ethernet, M12 connector, IO-Link ports Class A: 4, connection method: M12 connector, connection technology: 3-conductor, IO-Link ports Class B: 4, connection method: M12 connector, connection technology: 3-conductor, Digital inputs at pin 2 for class A ports: 4, 24 V DC, connection technology: 3-conductor, Metal housing, degree of protection: IP65/IP67
- 2701536 - Axioline E, Ethernet, M12 connector, IO-Link ports Class A: 4, connection method: M12 connector, connection technology: 3-conductor, IO-Link ports Class B: 4, connection method: M12 connector, connection technology: 3-conductor, Digital inputs at pin 2 for class A ports: 4, 24 V DC, connection technology: 3-conductor, Plastic housing, degree of protection: IP65/IP67
- 2701491 - Axioline E, EtherNet/IP™, M12 connector, IO-Link ports Class A: 4, connection method: M12 connector, connection technology: 3-conductor, IO-Link ports Class B: 4, connection method: M12 connector, connection technology: 3-conductor, Digital inputs at pin 2 for class A ports: 4, 24 V DC, connection technology: 3-conductor, Metal housing, degree of protection: IP65/IP67
- 2701496 - Axioline E, EtherNet/IP™, M12 connector, IO-Link ports Class A: 4, connection method: M12 connector, connection technology: 3-conductor, IO-Link ports Class B: 4, connection method: M12 connector, connection technology: 3-conductor, Digital inputs at pin 2 for class A ports: 4, 24 V DC, connection technology: 3-conductor, Plastic housing, degree of protection: IP65/IP67