AXL E EIP DIO16 M12 6P - Digital module

Axioline E, Digital I/O device, EtherNet/IP™, M12 connector, Digital inputs: 16, 24 V DC, connection technology: 4-conductor, Digital outputs: 16, 24 V DC, connection technology: 3-conductor, Plastic housing, degree of protection: IP65/IP67

  • Connection to EtherNet/IP™ network using M12 connectors (D-coded)
  • Transmission speed of 10 Mbps and 100 Mbps
  • Connection of digital sensors and actuators using M12connectors (A-coded)
  • Diagnostic and status indicators
  • Short-circuit and overload protection of the sensor supply
  • IP65/IP67 degree of protection
Technical Specifications

Dimensions

Width60 mm
Height185 mm
Depth30.5 mm
Drill hole spacing198.5 mm
Note on dimensionsThe height is 212 mm including fixing clips.

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Material specifications

Housing MaterialPocan®
Coloranthracite

Ethernet/IP™

Number of interfaces2
Connection MethodM12 connector
Note on the connection methodD-coded
Number of Positions4
Transmission Speed10/100 Mbps (with auto negotiation)
Equipment typeEtherNet/IP™ device
System-specific protocolsEtherNet/IP™ protocols ACD
System-specific protocolsEtherNet/IP™ protocols DLR
System-specific protocolsEtherNet/IP™ protocols IGMP v2
Protocols SupportedSNMP v1
Protocols SupportedHTTP
Protocols SupportedTFTP
Protocols SupportedFTP
Protocols SupportedBootP
Protocols SupportedDHCP
SpecificationCIP Edition 3.11EIP adaptation of CIP 1.12

Digital:

Input nameDigital inputs
Description of the inputEN 61131-2 types 1 and 3
Number of Inputs16
Cable Lengthmax. 30 m (to the sensor)
Connection MethodM12 connector, double occupancy
Connection technology4-conductor
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input voltage UIN24 V DC
Nominal input current at UINtyp. 3 mA
Sensor current per channeltyp. 75 mA (from US)
Total sensor currentmax. 1.2 A (per device)
Input filter time< 1000 µs
Protective circuitOverload protection, short-circuit protection of sensor supply
Output nameDigital outputs
Connection MethodM12 connector, double occupancy
Connection technology3-conductor
Number of Outputs16
Protective circuitOverload protection, short-circuit protection of outputs; yes
Output Voltage24 V DC
Limitation of the voltage induced on circuit interruption-28 V ... -17 V
Maximum Output Current per channel500 mA
Nominal Output Voltage24 V DC (from voltage US)
Output voltage range18 V DC ... 31.2 V DC
Output voltage when switched offmax. 1 V
Output current when switched offmax. 20 µA
Nominal load, inductive12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, ohmic12 W (48 Ω, with nominal voltage)
Switching frequencymax. 5500 per second (with at least 50 mA load current)
Switching frequencymax. 1 per second (with inductive load)
Reverse voltage resistance to short pulsesReverse voltage proof
Behavior with overloadAuto restart
Signal delaymax. 150 µs (when switched on)
Signal delaymax. 200 µs (when switched off)
Overcurrent shut-downmin. 0.7 A

Product properties

Product familyAxioline E
TypeStand-Alone
Special PropertiesPlastic housing

Potentials

Voltage supply US24 V DC
Power supply at USmax. 4 A
Current consumption from UStyp. 8 mA
Current consumption from USmax. 1.2 A

Supply: Module electronics, sensors, and actuators

DesignationModule electronics, sensors and actuators (US)
Connection MethodM12 connector (T-coded)
Number of Positions4
Supply Voltage24 V DC
Supply Voltage Range18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumptiontyp. 190 mA ±15 % (at 24 V DC)
Current consumptionmax. 12 A

Supply: Actuators

DesignationSupply of actuators (UA) for additional devices
Connection MethodM12 connector (T-coded)
Number of Positions4
Supply Voltage24 V DC
Supply Voltage Range18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumptiontyp. 3 mA ±15 % (at 24 V DC)
Current consumptionmax. 12 A

Electrical isolation/isolation of the voltage ranges

Test voltage: 24 V supply (communications power/sensor supply, digital inputs/outputs)/bus connection (Ethernet 1)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (communications power/sensor supply, digital inputs/outputs)/bus connection (Ethernet 2)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (communications power/sensor supply, digital inputs/outputs)/FE500 V AC, 50 Hz, 1 min.
Test voltage: Bus connection (Ethernet 1)/FE500 V AC, 50 Hz, 1 min.
Test voltage: Bus connection (Ethernet 2)/FE500 V AC, 50 Hz, 1 min.
Test voltage: Bus connection (Ethernet 1)/bus connection (Ethernet 2)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, digital inputs/outputs)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet 1)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet 2)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/FE500 V AC, 50 Hz, 1 min.

Connection data

Connection MethodM12 connector

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP65/IP67
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 %
Permissible humidity (storage/transport)5 % ... 95 %

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)
Accessories

Why Proax for Phoenix Contact AXL E EIP DIO16 M12 6P?

Proax is an authorized distributor of Phoenix Contact AXL E EIP DIO16 M12 6P and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Recommended

Available for order