Proax
fr0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
PHX2701488
MPN
2701488
Weight
0.722 kg

AXL E EIP DI16 M12 6M - Distributed I/O device

Axioline E, Digital input device, EtherNet/IP™, M12 connector, Digital inputs: 16, 24 V DC, connection technology: 4-conductor, Metal housing, degree of protection: IP65/IP67

  • Connection to EtherNet/IP™ network using M12 connectors (D-coded)
  • Transmission speed of 10 Mbps and 100 Mbps
  • Connection of digital sensors using M12connectors (A-coded)
  • Diagnostic and status indicators
  • Short-circuit and overload protection of the sensor supply
  • IP65/IP67 degree of protection
Technical Specifications

Dimensions

Width60 mm
Height185 mm
Depth38 mm
Drill hole spacing198.5 mm
Note on dimensionsThe height is 194.5 mm including the mounting panel. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting panel (30.5 mm without the mounting panel).

Material specifications

Housing MaterialZinc die-cast

Ethernet/IP™

Number of interfaces2
No. of channels2
Connection MethodM12 connector
Note on the connection methodD-coded
Number of Positions4
Transmission Speed10/100 Mbps (with auto negotiation)
Equipment typeEtherNet/IP™ device
System-specific protocolsEtherNet/IP™ protocols ACD
System-specific protocolsEtherNet/IP™ protocols DLR
System-specific protocolsEtherNet/IP™ protocols IGMP v2
Protocols SupportedSNMP v1
Protocols SupportedHTTP
Protocols SupportedTFTP
Protocols SupportedFTP
Protocols SupportedBootP
Protocols SupportedDHCP
SpecificationCIP Edition 3.11EIP adaptation of CIP 1.12

Digital:

Input nameDigital inputs
Description of the inputEN 61131-2 types 1 and 3
Number of Inputs16
Cable Lengthmax. 30 m (to the sensor)
Connection MethodM12 connector, double occupancy
Connection technology4-conductor
Input voltage range "0" signal0 V ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input voltage UIN24 V DC
Nominal input current at UINtyp. 3 mA
Sensor current per channeltyp. 75 mA (from US)
Total sensor currentmax. 1.2 A (per device)
Input filter time< 1000 µs
Protective circuitOverload protection, short-circuit protection of sensor supply

Product properties

Product familyAxioline E
TypeBlock design
Special PropertiesMetal housing

Potentials

Voltage supply US24 V DC
Power supply at USmax. 4 A
Current consumption from UStyp. 8 mA
Current consumption from USmax. 1.2 A

Supply: Module electronics and sensors

DesignationSupply of module electronics and sensors (US)
Connection MethodM12 connector (T-coded)
Number of Positions4
Supply Voltage24 V DC
Supply Voltage Range18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumptiontyp. 190 mA ±15 % (at 24 V DC)
Current consumptionmax. 12 A

Supply: Actuators

DesignationSupply of actuators (UA) for additional devices
Connection MethodM12 connector (T-coded)
Number of Positions4
Supply Voltage24 V DC
Supply Voltage Range18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumptiontyp. 3 mA ±15 % (at 24 V DC)
Current consumptionmax. 12 A

Electrical isolation/isolation of the voltage ranges

Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 1)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 2)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/FE500 V AC, 50 Hz, 1 min.
Test voltage: Bus connection (Ethernet 1)/FE500 V AC, 50 Hz, 1 min.
Test voltage: Bus connection (Ethernet 2)/FE500 V AC, 50 Hz, 1 min.
Test voltage: Bus connection (Ethernet 1)/bus connection (Ethernet 2)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, digital inputs)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet 1)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet 2)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/FE500 V AC, 50 Hz, 1 min.

Connection data

Connection MethodM12 connector

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP65/IP67
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 %
Permissible humidity (storage/transport)5 % ... 95 %

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeWall mounting or DIN rail mounting; both with mounting panel.
Accessories

Why Proax for Phoenix Contact AXL E EIP DI16 M12 6M?

Proax is an authorized distributor of Phoenix Contact AXL E EIP DI16 M12 6M and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience