Proax
fr0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

This item is Not Cancellable/Not Returnable.

SKU
PHX1185380
MPN
1185380
Weight
0.405 kg

AXL E IOL SDI8 SDO4 2A M12 L - Safety module

Axioline E-safety module, 4 safe digital inputs for 2-channel assignment, 8 safe digital inputs for 1-channel assignment, 4 safe digital +/-switching outputs, IO-Link interface, IP65/IP67 degree of protection, for PROFIsafe systems

  • Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
  • Minimum installation effort with control-cabinet-free mounting
  • Safe outputs with up to 2 A
  • Long service life and high system availability with the robust design
  • Connection of safe sensors and actuators directly at field level
  • Easy device addressing with address plug
Technical Specifications

Dimensions

Width59.8 mm
Height214 mm
Depth30 mm
Note on dimensionsSpecifications including fixing clips and connectors

Material specifications

Housing MaterialPlastic POCAN B4239 GF30 YE 1018

Digital:

Input nameSafe digital inputs
Description of the inputIEC 61131-2 type 3
Number of Inputs4 (for 2-channel assignment)
Number of Inputs8 (for 1-channel assignment)
Cable Lengthmax. 200 m
Connection MethodM12 connector (A-coded)
Connection technology3-conductor
Input voltage range "0" signal-30 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30.2 V DC
Nominal input voltage UIN24 V DC
Nominal input current at UINtyp. 3.7 mA (at 24 V DC)
Nominal input current at UINmax. 4.3 mA (with 30.2 V DC)
Input filter time1.5 ms
Input filter time3 ms (Default)
Input filter time5 ms
Input filter time15 ms
Protective circuitOverload protection, short-circuit protection of sensor supply

IO-Link

Number of Ports1
Connection MethodM12 connector, A-coded
Connection technology3-conductor
Port TypeClass A
SpecificationV1.1.2
Reverse polarity protectionyes
Transmission Speed230.4 kbps (COM3)
Cycle Time≥ 4 ms
Process data update≥ 4 ms
Amount of Process Data64 bit (Input and output data)

Digital:

Output nameSafe digital outputs
Connection MethodM12 connector (A-coded)
Connection technology2-conductor
Number of Outputs4 (for 2-channel assignment, +/- switching)
Number of Outputs4 (for 1-channel assignment, + switching)
Protective circuitOverload protection, short-circuit protection of outputs
Output VoltageUA - 1.4 V
Output Currentmax. 2 A (per channel)
Output Currentmax. 2 A (per output)
Output Currentmax. 6 A (Total current of all outputs; Please observe the notes in the user manual.)
Maximum Output Current per channel2 A
Nominal Output Voltage24 V DC (from voltage UA)
Load min.2.4 kΩ (10 mA at 24 V DC)
Output voltage when switched off< 5 V ((in the Low state))
Output current when switched off2 mA (Leakage current in the Low state)
Delay timemax. 128 s (can be parameterized)
Permissible cable lengthmax. 50 m
Switching frequencymax. 1 Hz
Reverse voltage resistance to short pulsesno

Product properties

Product familyAxioline E
ApplicationFunctional safety
TypeStand-Alone
Mounting Positionany
Operating modeProcess data mode with 4 words

Insulation characteristics

Pollution degree4

Supply: IO-Link

DesignationIO-Link port supply (L+)
Nominal voltage for I/O supply24 V DC (Provided via the IO-Link interface of the IO-Link master.)
Supply Voltage Range19.2 V DC ... 30.2 V DC (including all tolerances, including ripple)
Nominal current per deviceapprox. 15 mA
Permissible cable lengthmax. 20 m
Protective circuitReverse polarity protection

Supply: Module electronics and sensors

DesignationSupply of module electronics and sensors (US)
Connection MethodM12 connector (L-coded)
Number of Positions2
Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30.2 V DC (including all tolerances, including ripple)
Current consumption67 mA (without sensors)
Protectionmax. 8 A (slow-blow)

Supply: Actuators

DesignationActuator supply (UA)
Connection MethodM12 connector (L-coded)
Number of Positions2
Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30.2 V DC (including all tolerances, including ripple)
Current consumption52 A (without actuators)
Protectionmax. 8 A (slow-blow)

Connection data

Connection MethodM12 connector
Note on the connection methodin accordance with IEC 61076-2-101, M12 connection technology

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C (Mounting position: any)
Degree of ProtectionIP65/IP67 (in accordance with DIN EN 60529:1989 + A1:1999 + A2:2013)
NoteResistant to gas that may endanger functions (sulfur dioxide (SO2), hydrogen sulfide (H2S))
Air pressure (operation)70 kPa ... 108 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (storage/transport)75 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Air clearances and creepage distances

Air clearances and creepage distancesin accordance with IEC 60664-1

Mounting

Mounting Positionany

Why Proax for Phoenix Contact AXL E IOL SDI8 SDO4 2A M12 L?

Proax is an authorized distributor of Phoenix Contact AXL E IOL SDI8 SDO4 2A M12 L and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Recommended

Available for order