AXL E IOL SDI8 SDO4 2A M12 L - Safety module
Axioline E-safety module, 4 safe digital inputs for 2-channel assignment, 8 safe digital inputs for 1-channel assignment, 4 safe digital +/-switching outputs, IO-Link interface, IP65/IP67 degree of protection, for PROFIsafe systems
- Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
- Minimum installation effort with control-cabinet-free mounting
- Safe outputs with up to 2 A
- Long service life and high system availability with the robust design
- Connection of safe sensors and actuators directly at field level
- Easy device addressing with address plug
Technical Specifications
Dimensions
Width | 59.8 mm |
Height | 214 mm |
Depth | 30 mm |
Note on dimensions | Specifications including fixing clips and connectors |
Material specifications
Housing Material | Plastic POCAN B4239 GF30 YE 1018 |
Digital:
Input name | Safe digital inputs |
Description of the input | IEC 61131-2 type 3 |
Number of Inputs | 4 (for 2-channel assignment) |
Number of Inputs | 8 (for 1-channel assignment) |
Cable Length | max. 200 m |
Connection Method | M12 connector (A-coded) |
Connection technology | 3-conductor |
Input voltage range "0" signal | -30 V DC ... 5 V DC |
Input voltage range "1" signal | 11 V DC ... 30.2 V DC |
Nominal input voltage UIN | 24 V DC |
Nominal input current at UIN | typ. 3.7 mA (at 24 V DC) |
Nominal input current at UIN | max. 4.3 mA (with 30.2 V DC) |
Input filter time | 1.5 ms |
Input filter time | 3 ms (Default) |
Input filter time | 5 ms |
Input filter time | 15 ms |
Protective circuit | Overload protection, short-circuit protection of sensor supply |
IO-Link
Number of Ports | 1 |
Connection Method | M12 connector, A-coded |
Connection technology | 3-conductor |
Port Type | Class A |
Specification | V1.1.2 |
Reverse polarity protection | yes |
Transmission Speed | 230.4 kbps (COM3) |
Cycle Time | ≥ 4 ms |
Process data update | ≥ 4 ms |
Amount of Process Data | 64 bit (Input and output data) |
Digital:
Output name | Safe digital outputs |
Connection Method | M12 connector (A-coded) |
Connection technology | 2-conductor |
Number of Outputs | 4 (for 2-channel assignment, +/- switching) |
Number of Outputs | 4 (for 1-channel assignment, + switching) |
Protective circuit | Overload protection, short-circuit protection of outputs |
Output Voltage | UA - 1.4 V |
Output Current | max. 2 A (per channel) |
Output Current | max. 2 A (per output) |
Output Current | max. 6 A (Total current of all outputs; Please observe the notes in the user manual.) |
Maximum Output Current per channel | 2 A |
Nominal Output Voltage | 24 V DC (from voltage UA) |
Load min. | 2.4 kΩ (10 mA at 24 V DC) |
Output voltage when switched off | < 5 V ((in the Low state)) |
Output current when switched off | 2 mA (Leakage current in the Low state) |
Delay time | max. 128 s (can be parameterized) |
Permissible cable length | max. 50 m |
Switching frequency | max. 1 Hz |
Reverse voltage resistance to short pulses | no |
Product properties
Product family | Axioline E |
Application | Functional safety |
Type | Stand-Alone |
Mounting Position | any |
Operating mode | Process data mode with 4 words |
Insulation characteristics
Pollution degree | 4 |
Supply: IO-Link
Designation | IO-Link port supply (L+) |
Nominal voltage for I/O supply | 24 V DC (Provided via the IO-Link interface of the IO-Link master.) |
Supply Voltage Range | 19.2 V DC ... 30.2 V DC (including all tolerances, including ripple) |
Nominal current per device | approx. 15 mA |
Permissible cable length | max. 20 m |
Protective circuit | Reverse polarity protection |
Supply: Module electronics and sensors
Designation | Supply of module electronics and sensors (US) |
Connection Method | M12 connector (L-coded) |
Number of Positions | 2 |
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30.2 V DC (including all tolerances, including ripple) |
Current consumption | 67 mA (without sensors) |
Protection | max. 8 A (slow-blow) |
Supply: Actuators
Designation | Actuator supply (UA) |
Connection Method | M12 connector (L-coded) |
Number of Positions | 2 |
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30.2 V DC (including all tolerances, including ripple) |
Current consumption | 52 A (without actuators) |
Protection | max. 8 A (slow-blow) |
Connection data
Connection Method | M12 connector |
Note on the connection method | in accordance with IEC 61076-2-101, M12 connection technology |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C (Mounting position: any) |
Degree of Protection | IP65/IP67 (in accordance with DIN EN 60529:1989 + A1:1999 + A2:2013) |
Note | Resistant to gas that may endanger functions (sulfur dioxide (SO2), hydrogen sulfide (H2S)) |
Air pressure (operation) | 70 kPa ... 108 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (storage/transport) | 75 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Air clearances and creepage distances
Air clearances and creepage distances | in accordance with IEC 60664-1 |
Mounting
Mounting Position | any |
Why Proax for Phoenix Contact 1185380?
Proax is an authorized distributor of Phoenix Contact 1185380 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 2701541 - Axioline E, Ethernet, M12 connector, IO-Link ports Class A: 4, connection method: M12 connector, connection technology: 3-conductor, IO-Link ports Class B: 4, connection method: M12 connector, connection technology: 3-conductor, Digital inputs at pin 2 for class A ports: 4, 24 V DC, connection technology: 3-conductor, Metal housing, degree of protection: IP65/IP67
- 2701536 - Axioline E, Ethernet, M12 connector, IO-Link ports Class A: 4, connection method: M12 connector, connection technology: 3-conductor, IO-Link ports Class B: 4, connection method: M12 connector, connection technology: 3-conductor, Digital inputs at pin 2 for class A ports: 4, 24 V DC, connection technology: 3-conductor, Plastic housing, degree of protection: IP65/IP67