SKU
MPN
PSR-MC30-2NO-1DO-24DC-SC
Series PSR-MC

PSR-MC30-2NO-1DO-24DC-SC - Safety relays

Safety relay for emergency stop and safety doors up to SIL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic or manual, monitored start, cross-circuit detection, 2 enabling current paths, US = 24 V DC, plug-in screw terminal block

  • Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061
  • Cross-circuit detection
  • Low housing width of just 12.5 mm
  • Manually monitored and automatic activation in a single device
  • 2 enabling current paths, 1 digital signal output
  • 2 channel control
Technical Specifications

Product properties

Product familyPSRmini
ApplicationEmergency stop
ApplicationSafety door
ApplicationSolenoid switch
Mechanical service lifeapprox. 107 cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Times

Typical response time< 175 ms (automatic start)
Typical response time< 175 ms (manual, monitored start)
Typ. starting time with Us< 250 ms (when controlled via A1)
Typical release time< 20 ms (on demand via A1)
Typical release time< 20 ms (on demand via the sensor circuit)
Restart time< 1 s (Boot time, after switching on the supply voltage)
Recovery time< 500 ms (following demand of the safety function)

Electrical properties

Maximum power dissipation for nominal condition5.5 W (US = 26.4 V, IL² = 72 A², PTotal max =1.9 W + 3.6 W)
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated Insulation Voltage250 V AC
Rated surge voltage/insulationSee section “Insulation coordination”

Supply

DesignationA1/A2
Rated control circuit supply voltage US20.4 V DC ... 26.4 V DC
Rated control circuit supply voltage US24 V DC -15 % / +10 %
Rated control supply current IStyp. 65 mA (at US)
Power consumption at UStyp. 1.56 W
Inrush Currenttyp. 4 A (Δt = 200 µs at Us)
Filter time1 ms (in the event of voltage dips at Us)
Protective circuitSerial protection against polarity reversal; Suppressor diode

Digital: Sensor circuit (S12, S22)

Description of the inputsafety-related sensor inputs
Description of the inputNPN (S12), NPN/PNP (S22)
Number of Inputs2
Input voltage range "0" signal< 5 V (S12)
Input voltage range "0" signalInput S22 can interpret low-resistance outputs of a PLC as a continuous HIGH signal.
Input voltage range "1" signal20.4 V ... 26.4 V
Input current range "0" signal< 2 mA (S12)
Input current range "0" signal0 mA ... 2 mA (S22)
Inrush Current< 20 mA (Typically with US at S12)
Inrush Current< 5 mA (typically with US at S22/24 V)
Inrush Current> -15 mA (typically with US at S22/0 V)
Filter timemax. 1.5 ms (at S12, S22; test pulse width)
Filter timemin. 7.5 ms (at S12, S22; test pulse rate)
Concurrence
Max. permissible overall conductor resistance150 Ω
Protective circuitSuppressor diode
Current consumption< 5 mA (Typically with US at S12)
Current consumption< 5 mA (typically with US at S22/24 V)
Current consumption> -5 mA (typically with US at S22/0 V)

Digital: Start circuit (S34)

Description of the inputnon-safety-related
Description of the inputNPN/PNP
Number of Inputs1
Input voltage range "1" signal20.4 V DC ... 26.4 V DC
Inrush Currentmax. 200 mA (typically with US)
Max. permissible overall conductor resistance150 Ω
Protective circuitSuppressor diode
Current consumption< 10 mA (at S34/24 V)
Current consumption> -5 mA (at S34/0 V)

Relay: Enabling current paths (13/14, 23/24)

Output descriptionsafety-related N/O contacts
Number of Outputs2 (undelayed)
Contact switching type2 enabling current paths
Contact MaterialAgSnO2
Switching voltagemin. 12 V
Switching voltagemax. 250 V AC/DC (Observe the load curve)
Switching capacitymin. 60 mW
Inrush Currentmin. 3 mA
Inrush Currentmax. 6 A
Switching capacity in accordance with IEC 60947-5-15 A (AC15)
Switching capacity in accordance with IEC 60947-5-14 A (DC13)
Limiting Continuous Current6 A (observe derating)
Sq. Total current72 A2 (observe derating)
Switching frequency0.5 Hz
Mechanical service life10x 106 cycles
Output fuse6 A gL/gG
Output fuse4 A gL/gG (for low-demand applications)

Signal: M1

Output descriptionnon-safety-related
Number of Outputs1 (digital, PNP)
Voltage22 V DC (Us - 2 V)
Currentmax. 100 mA
Maximum Inrush Current500 mA (Δt = 1 ms at Us)
Switching frequency0.5 Hz (Resistive, inductive, capacitive)
Protective circuitSuppressor diode
Short-circuit protectionno

Connection technology

pluggableyes

Conductor connection

Connection MethodScrew connection
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 12
Stripping length7 mm
Screw threadM3
Tightening torque0.5 Nm ... 0.6 Nm

Signaling

Status display3 x green LED
Operating voltage display1 x green LED

Dimensions

Width12.5 mm
Height112.2 mm
Depth114.5 mm

Material specifications

Color (Housing)yellow (RAL 1018)
Housing MaterialPolyamide

Safety data

Stop category0

Safety data: EN ISO 13849

Category4
Performance level (PL)e (4 A DC13; 5 A AC15; 8760 switching cycles/year)

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)3

Safety data: IEC 61508 - Low demand

Safety Integrity Level (SIL)3

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-40 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

CE

IdentificationCE-compliant

Air clearances and creepage distances between the power circuits

Standards/regulationsEN 60947-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsSee derating curve
Mounting Positionvertical or horizontal

Why Proax for Phoenix Contact 2700498?

Proax is an authorized distributor of Phoenix Contact 2700498 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability