PSR-MC38-2NO-1DO-24DC-PI - Safety relays
Safety relay for emergency stop, safety doors and light grids up to SIL 3, Cat. 4, PL e, 1- or 2-channel operation, automatic or manual, monitored start, 2 enabling current paths, 1 signal output, TBUS interface, US = 24 V DC, pluggable push-in terminal
- Up to Cat. 4/PL e in accordance with ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
- 1- and 2-channel control
- 2 enabling current paths, 1 digital signal output
- For emergency stop and safety door monitoring, plus evaluation of light grids
- TBUS interface for connecting CONTACTRON hybrid motor starters and MINI POWER power supplies
Technical Specifications
Product properties
Product family | PSRmini |
Application | Emergency stop |
Application | Safety door |
Application | Light grid |
Application | Solenoid switch |
Application | Transponder |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Times
Typical response time | 30 ms (manual, monitored start) |
Typical response time | 200 ms (automatic start) |
Typ. starting time with Us | 200 ms (when controlled via A1) |
Typical release time | 25 ms (when actuation is via the sensor circuit) |
Typical release time | 60 ms (when controlled via A1) |
Restart time | < 1 s (Boot time) |
Recovery time | < 500 ms |
Electrical properties
Maximum power dissipation for nominal condition | 16.6 W (at US = 26.4 V, IL² = 72 A²) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V |
Rated Insulation Voltage | 250 V |
Supply
Designation | A1/A2 |
Rated control circuit supply voltage US | 20.4 V DC ... 26.4 V DC |
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % (provide external protection) |
Rated control supply current IS | typ. 75 mA |
Power consumption at US | typ. 1.8 W |
Inrush Current | < 4 A (Δt = 3 ms at Us) |
Filter time | 20 ms (at A1 in the event of voltage dips at Us) |
Protective circuit | Serial protection against polarity reversal; Suppressor diode |
Digital: Sensor circuit (S10, S12, S13, S22)
Description of the input | safety-related sensor inputs |
Number of Inputs | 4 |
Input voltage range "1" signal | 20.4 V DC ... 26.4 V DC |
Inrush Current | < 40 mA (typ. with US at S10) |
Inrush Current | < 300 mA (typ. with US at S12, Δt = 150 ms) |
Inrush Current | < 3 mA (Typically with US at S13) |
Inrush Current | > -300 mA (Typically with US at S22, Δt = 150 ms) |
Filter time | 2 ms (At S10, S12, S13; test pulse width of low test pulses) |
Filter time | 1 s (At S10, S12, S13; test pulse rate of low test pulses) |
Filter time | No brightness test pulses / high test pulses permitted. |
Concurrence | ∞ |
Max. permissible overall conductor resistance | 50 Ω |
Protective circuit | Suppressor diode |
Current consumption | 40 mA (typ. with US at S10) |
Current consumption | 45 mA (Typically with US at S12) |
Current consumption | 3 mA (Typically with US at S13) |
Current consumption | -35 mA (Typically with US at S22, Δt = 150 ms) |
Digital: Start circuit (Y1, S34, S35)
Description of the input | non-safety-related |
Input voltage range "1" signal | 20.4 V DC ... 26.4 V DC |
Inrush Current | < 60 mA (Typically with US at Y1, Δt = 150 ms) |
Inrush Current | < 270 mA (Typically with US at S34, Δt = 15 ms) |
Inrush Current | < 80 mA (Typically with US at S35, Δt = 25 ms) |
Filter time | No darkness test pulses / low test pulses permitted. No brightness test pulses / high test pulses permitted. |
Max. permissible overall conductor resistance | 50 Ω |
Protective circuit | Suppressor diode |
Current consumption | typ. 10 mA (Typically with US at Y1) |
Current consumption | typ. 34 µA (Typically with US at S35) |
Relay: Enabling current path (13/14, 23/24)
Output description | safety-related N/O contacts |
Output description | 2 NO contacts each in series, without delay, floating |
Number of Outputs | 2 (undelayed) |
Contact switching type | 2 enabling current paths |
Contact Material | AgSnO2 |
Switching voltage | min. 10 V AC/DC |
Switching voltage | max. 250 V AC/DC (Observe the load curve) |
Switching capacity | min. 100 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (24 V (DC13)) |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (250 V (AC15)) |
Limiting Continuous Current | 6 A |
Sq. Total current | 72 A2 (observe derating) |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 10 A gL/gG |
Output fuse | 4 A gL/gG (for low-demand applications) |
Signal: Y30
Output description | PNP |
Output description | non-safety-related |
Number of Outputs | 1 |
Voltage | approx. 23.9 V DC (Us - 0.1 V) |
Current | max. 100 mA |
Maximum Inrush Current | 500 mA (Δt = 1 ms at Us) |
Protective circuit | Suppressor diode |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 14 |
Stripping length | 10 mm |
Signaling
Status display | 4 x green LEDs |
Operating voltage display | 1 x green LED |
Dimensions
Width | 22.5 mm |
Height | 117.5 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide |
Safety data
Stop category | 0 |
Safety data: EN ISO 13849
Category | 4 (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
Performance level (PL) | e |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 |
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL) | 3 |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -20 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (Operation) | 10 Hz ... 150 Hz, 2g |
CE
Identification | CE-compliant |
Air clearances and creepage distances between the power circuits
Standards/regulations | IEC 60664-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | See derating curve |
Mounting Position | vertical or horizontal |
Accessories
- Démarreur moteur hybride comme alternative au circuit de protection contacteur-inverseur classique. Inverse les moteurs 3~ AC jusqu'à 3 A, offre une protection moteur et un arrêt d'urgence jusqu'à SIL 3 / PL e. Coupure de groupe, alimentation et extension de relais possibles via des connecteurs de bus sur rails DIN.
Why Proax for Phoenix Contact 1009832?
Proax is an authorized distributor of Phoenix Contact 1009832 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended