Series PSR-MC

PSR-MC20-3NO-1DO-24DC-SC - Safety relays

Safety relay for emergency stop and safety doors up to SIL 1, Cat. 1, PL c, depending on the application up to SIL 3, Cat. 4, PL e, 1-channel operation, automatic/manual start, 3 enabling current paths, US = 24 V DC, plug-in screw terminal block

  • Up to Cat. 1/PL c in accordance with EN ISO 13849-1, SIL 1 in accordance with EN IEC 62061
  • Depending on the application, up to cat. 4/PL e in accordance with ISO 13849-1, SIL CL 3 in accordance with EN IEC 62061
  • Low housing width of just 12.5 mm
  • Manually monitored and automatic activation in a single device
  • 3 enabling current paths, 1 digital signal output
  • 1-channel control
Technical Specifications

Product properties

Product familyPSRmini
ApplicationEmergency stop
ApplicationSafety door
ApplicationSolenoid switch
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Times

Typical response time< 175 ms (automatic start)
Typical response time< 175 ms (manual, monitored start)
Typ. starting time with Us< 250 ms (when controlled via A1)
Typical release time< 20 ms (when controlled via A1 or S12)
Recovery time< 500 ms

Electrical properties

Maximum power dissipation for nominal condition4.8 W (US = 26.4 V, IL² = 48 A², PTotal max = 2.4 W + 2.4 W)
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated Insulation Voltage250 V AC
Rated surge voltage/insulationSafe isolation, reinforced insulation 6 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) and enabling current path (33/34)Basic insulation 4 kV between all current paths and housing

Supply

DesignationA1/A2
Rated control circuit supply voltage US20.4 V DC ... 26.4 V DC
Rated control circuit supply voltage US24 V DC -15 % / +10 %
Rated control supply current IStyp. 80 mA
Power consumption at UStyp. 1.92 W
Inrush Current5 A (Δt = 200 µs at Us)
Filter time1 ms (at A1 in the event of voltage dips at Us)
Protective circuitSurge protection; Suppressor diode
Protective circuitProtection against polarity reversal for rated control circuit supply voltage

Digital: Start circuit (S34)

Description of the inputnon-safety-related
Number of Inputs1
Input voltage range "1" signal20.4 V DC ... 26.4 V DC
Inrush Currenttyp. 200 mA
Max. permissible overall conductor resistance150 Ω
Protective circuitSuppressor diode
Current consumption< 10 mA (at S34/24 V)
Current consumption> -5 mA (at S34/0 V)

Relay: Enabling current paths (13/14, 23/24, 33/34)

Output descriptionsafety-related N/O contacts
Number of Outputs3 (undelayed)
Contact switching type3 enabling current paths
Contact MaterialAgSnO2
Switching voltagemin. 12 V AC/DC
Switching voltagemax. 250 V AC/DC (Observe the load curve)
Switching capacitymin. 60 mW
Inrush Currentmin. 3 mA
Inrush Currentmax. 6 A
Limiting Continuous Current6 A (observe derating)
Sq. Total current48 A2 (observe derating)
Switching frequency0.5 Hz
Mechanical service life10x 106 cycles
Output fuse6 A gL/gG (N/O contact)
Output fuse4 A gL/gG (for low-demand applications)

Signal: M1

Output descriptionnon-safety-related
Number of Outputs1 (digital, PNP)
Voltage22 V DC (Us - 2 V)
Currentmax. 100 mA
Maximum Inrush Current500 mA (Δt = 1 ms at Us)
Short-circuit protectionno

Connection technology

pluggableyes

Conductor connection

Connection MethodScrew connection
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 12
Stripping length7 mm
Screw threadM3
Tightening torque0.5 Nm ... 0.6 Nm

Signaling

Status display3 x green LED
Operating voltage display1 x green LED

Dimensions

Width12.5 mm
Height112.2 mm
Depth114.5 mm

Material specifications

Color (Housing)yellow (RAL 1018)
Housing MaterialPolyamide

Safety data

Stop category0

Safety data: EN ISO 13849

Category1 (up to Cat. 4 depending on the application)
Performance level (PL)c (up to PL e depending on the application)

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)1 (up to SIL 3 depending on the application)

Safety data: IEC 61508 - Low demand

Safety Integrity Level (SIL)1 (up to SIL 3 depending on the application)

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3 (up to SIL 3 depending on the application)

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-40 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

CE

IdentificationCE-compliant

Air clearances and creepage distances between the power circuits

Standards/regulationsEN 60947-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsSee derating curve
Mounting Positionvertical or horizontal

Why Proax for Phoenix Contact 2700466?

Proax is an authorized distributor of Phoenix Contact 2700466 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability