Official Distributor
SKU
MPN
PSR-MC32-3NO-1NC-24-230UC-SC
Weight
0.244 kg
Series PSR-MC
PSR-MC32-3NO-1NC-24-230UC-SC - Safety relays
Safety relay for emergency stop, safety doors, and light grids up to SIL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic or manual, monitored start, 3 enabling current paths, 1 signaling current path, US = 24 ... 230 V AC/DC, plug-in screw terminal block
- Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061
- 1 or 2-channel control
- 3 enabling current paths, 1 signaling current path
- Manually monitored and automatic activation in a single device
- Cross-circuit detection
Technical Specifications
Product properties
Product family | PSRmini |
Application | Emergency stop |
Application | Safety door |
Application | Solenoid switch |
Application | Transponder |
Application | Light grid |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Times
Typical response time | < 150 ms (automatic start) |
Typical response time | < 100 ms (manual, monitored start) |
Typ. starting time with Us | < 200 ms (when controlled via A1) |
Typical release time | < 20 ms (when actuation is via the sensor circuit) |
Restart time | < 1 s |
Recovery time | < 500 ms |
Electrical properties
Maximum power dissipation for nominal condition | 17.3 W (at IL² = 72 A²) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V AC |
Rated surge voltage/insulation | Basic insulation 4 kV between enabling current path (23/24) and enabling current path (33/34) and signaling current path (41/42) |
Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV between all other circuits |
Supply
Designation | A1/A2 |
Rated control circuit supply voltage US | 24 V AC/DC ... 230 V AC/DC -15 % / +10 % |
Rated control supply current IS | typ. 103 mA (24 V DC) |
Rated control supply current IS | typ. 47 mA (48 V DC) |
Rated control supply current IS | typ. 38 mA (110 V AC) |
Rated control supply current IS | typ. 21 mA (230 V AC) |
Power consumption at US | 2.7 W (with DC) |
Power consumption at US | 2.9 W (with AC) |
Apparent power | typ. 5 VA (at US) |
Inrush Current | < 80 A (Δt = 50 µs at Us) |
Filter time | 2 ms (at A1 in the event of voltage dips at Us) |
Protective circuit | US: surge protection; 275 V varistor / 411 V suppressor diode |
Digital: Sensor circuit (S10, S12, S13, S22)
Description of the input | safety-related sensor inputs |
Number of Inputs | 4 |
Input voltage range "0" signal | 0 V DC ... 5 V DC (for safe Off; at S10/S12/S13) |
Input current range "0" signal | 0 mA ... 2 mA (for safe Off; at S10/S12/S13) |
Inrush Current | < 5 mA (with Us/Ix at S10/S12/S13) |
Inrush Current | > -5 mA (with Us/Ix to S22) |
Filter time | max. 1.5 ms (to S10-S12; test pulse width; at 24 V DC) |
Filter time | 7.5 ms (to S10-S12; test pulse rate; at 24 V DC) |
Filter time | Test pulse rate = 5 x Test pulse width |
Concurrence | ∞ |
Max. permissible overall conductor resistance | 150 Ω |
Protective circuit | Inputs: protection against polarity reversal, surge protection; 38.6 V suppressor diode |
Current consumption | < 5 mA (with Us/Ix at S10/S12/S13) |
Current consumption | > -5 mA (with Us/Ix to S22) |
Digital: Start circuit (S34, S35)
Description of the input | non-safety-related |
Number of Inputs | 2 |
Inrush Current | < 10 mA (Δt = 330 ms) |
Max. permissible overall conductor resistance | 150 Ω |
Protective circuit | Suppressor diode |
Voltage at input/start and feedback circuit | 24 V DC -20 % / +25 % |
Current consumption | typ. 2.5 mA (S34) |
Current consumption | typ. 1 mA (S35) |
Relay: Enabling current paths (13/14, 23/24, 33/34)
Output description | safety-related N/O contacts |
Number of Outputs | 3 (undelayed) |
Contact switching type | 3 enabling current paths |
Contact Material | AgSnO2 |
Switching voltage | min. 5 V AC/DC |
Switching voltage | max. 250 V AC/DC (Observe the load curve) |
Switching capacity | min. 50 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (24 V (DC13)) |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (250 V (AC15)) |
Limiting Continuous Current | 6 A (observe derating) |
Sq. Total current | 72 A2 (observe derating) |
Switching frequency | max. 1 Hz |
Mechanical service life | 10x 106 cycles |
Interrupting rating (ohmic load) max. | 1500 VA (250 V AC, τ = 0 ms) |
Interrupting rating (ohmic load) max. | For additional values, see load curve |
Maximum interrupting rating (inductive load) | 48 W (24 V DC, τ = 40 ms) |
Maximum interrupting rating (inductive load) | 40 W (48 V DC, τ = 40 ms) |
Maximum interrupting rating (inductive load) | 36 W (60 V DC, τ = 40 ms) |
Maximum interrupting rating (inductive load) | 35 W (110 V DC, τ = 40 ms) |
Maximum interrupting rating (inductive load) | 33 W (220 V DC, τ = 40 ms) |
Maximum interrupting rating (inductive load) | 1500 VA (250 V AC, τ = 40 ms) |
Output fuse | 6 A gL/gG |
Output fuse | 4 A gL/gG (for low-demand applications) |
Relay: Signaling current path (41/42)
Output description | non-safety-related N/C contact |
Number of Outputs | 1 (undelayed) |
Contact switching type | 1 signaling current path |
Contact Material | AgSnO2 |
Switching voltage | min. 5 V AC/DC |
Switching voltage | max. 250 V AC/DC |
Switching capacity | min. 50 mW |
Inrush Current | min. 10 mA |
Inrush Current | max. 6 A |
Limiting Continuous Current | 6 A |
Switching frequency | 1 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 6 A gL/gG |
Output fuse | 4 A gL/gG (for low-demand applications) |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Screw connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Signaling
Status display | 3 x green LED |
Operating voltage display | 1 x green LED |
Dimensions
Width | 22.5 mm |
Height | 112.2 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide |
Safety data
Stop category | 0 |
Safety data: EN ISO 13849
Category | 4 |
Performance level (PL) | e |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 |
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL) | 3 |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -40 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (Operation) | 10 Hz ... 150 Hz, 2g |
CE
Identification | CE-compliant |
Air clearances and creepage distances between the power circuits
Standards/regulations | EN 60947-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | See derating curve |
Mounting Position | vertical or horizontal |
Why Proax for Phoenix Contact 2700524?
Proax is an authorized distributor of Phoenix Contact 2700524 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended