Official Distributor
SKU
MPN
PSR-MC42-2NO-1DO-24DC-SC
Weight
0.188 kg
This product is Not Cancellable/Not Returnable
Series PSR-MC
PSR-MC42-2NO-1DO-24DC-SC - Safety relays
Safety relay with IO-Link for emergency stop, safety doors, and light grids, up to SIL 3, Cat. 4, PL e, 2 sensor circuits, automatic or manual, monitored start, 2 enabling current paths, 1 signal output, US = 24 V DC, plug-in screw terminal block
- 2 enabling current paths, 1 digital signal output
- Diagnostic data via IO-Link in combination with PSR-CT safety switches
- For emergency stop and safety door monitoring, plus evaluation of light grids
- Automatic and manual activation
- 1- and 2-channel control
- 2 sensor circuits
- Up to Cat. 4/PL e in accordance with ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
Technical Specifications
Product properties
Product family | PSRmini |
Application | Emergency stop |
Application | Safety door |
Application | Light grid |
Application | Solenoid switch |
Application | Transponder |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Times
Typical response time | < 220 ms (automatic start) |
Typical response time | < 175 ms (manual, monitored start) |
Typ. starting time with Us | < 250 ms (when controlled via A1) |
Typical release time | < 20 ms (on demand via the sensor circuit) |
Typical release time | < 20 ms (on demand via A1) |
Restart time | < 1 s (Boot time) |
Recovery time | < 500 ms |
Electrical properties
Maximum power dissipation for nominal condition | 6.45 W (US = 30 V, UL = 30 V, I² = 72 A²) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 320 V |
Rated Insulation Voltage | 320 V |
Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
Rated surge voltage/insulation | Safe isolation, reinforced insulation 4 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) |
Supply
Designation | L+/L- |
Nominal voltage for I/O supply | 24 V DC -20 % / +25 % (Provided via the IO-Link interface of the IO-Link master.) |
Current consumption | typ. 16 mA |
Protective circuit | Serial protection against polarity reversal; Suppressor diode |
Designation | A1/A2 |
Rated control circuit supply voltage US | 19.2 V DC ... 30 V DC |
Rated control circuit supply voltage US | 24 V DC -20 % / +25 % (provide external protection) |
Rated control supply current IS | typ. 60 mA |
Power consumption at US | typ. 1.44 W |
Inrush Current | typ. 2.5 A (Δt = 500 µs at Us) |
Filter time | 1 ms (at A1 in the event of voltage dips at Us) |
Protective circuit | Serial protection against polarity reversal; Suppressor diode |
Digital: Sensor circuit S0 (S12, S22)
Description of the input | safety-related sensor inputs |
Number of Inputs | 2 |
Input voltage range "0" signal | 0 V DC ... 5 V DC (S12) |
Input voltage range "0" signal | For S22, see note in “Signal generator connection versions” section. |
Input voltage range "1" signal | 11 V DC ... 30 V DC |
Input current range "0" signal | 0 mA ... 2 mA (S12, S22) |
Inrush Current | < 5 mA (typ. with US at S12, Δt = 150 ms) |
Inrush Current | < 5 mA (typically with US at S22/24 V, Δt = 500 µs) |
Inrush Current | > -5 mA (typically with US at S22/0 V, Δt = 500 µs) |
Filter time | 1.5 ms (Test pulse width of low test pulses) |
Filter time | Test pulse rate = 5 x Test pulse width |
Filter time | Deactivate the switch-on pulses for safety applications. |
Concurrence | ∞ |
Max. permissible overall conductor resistance | 150 Ω |
Protective circuit | Suppressor diode |
Current consumption | < 5 mA (Typically with US at S12) |
Current consumption | < 5 mA (typically with US at S22/24 V) |
Current consumption | > -5 mA (typically with US at S22/0 V) |
Digital: Sensor circuit S1 (S32, S42)
Description of the input | safety-related sensor inputs |
Number of Inputs | 2 |
Input voltage range "0" signal | 0 V DC ... 5 V DC |
Input voltage range "1" signal | 11 V DC ... 30 V DC |
Input current range "0" signal | 0 mA ... 2 mA |
Inrush Current | < 20 mA (typically with US) |
Filter time | max. 1.5 ms (Test pulse width of low test pulses) |
Filter time | Test pulse rate = 5 x Test pulse width |
Filter time | Deactivate the switch-on pulses for safety applications. |
Concurrence | ∞ |
Max. permissible overall conductor resistance | 150 Ω |
Protective circuit | Suppressor diode |
Current consumption | < 5 mA (typically with US) |
Digital: Diagnostic input (DGN)
Description of the input | non-safety-related |
Number of Inputs | 1 |
Input voltage range | 0 V DC ... 30 V DC |
Protective circuit | Suppressor diode |
Current consumption | typ. 30 mA |
Digital: Start circuit (S34)
Number of Inputs | 1 |
Input voltage range "1" signal | 19.2 V DC ... 30 V DC (manual start, autostart: 0 V) |
Inrush Current | < 10 mA (typically with US, Δt = 100 ms) |
Max. permissible overall conductor resistance | 150 Ω |
Protective circuit | Suppressor diode |
Current consumption | < 5 mA (typically with US at S34/24 V) |
Current consumption | > -5 mA (typically with US at S34/0 V) |
IO-Link
Designation | IO-Link |
Transmission Speed | 230 kbps (COM3) |
Cycle Time | 5 ms |
Process data update | 5 ms |
Amount of Process Data | max. 31 Byte (Input data) |
Amount of Process Data | max. 16 Byte (Output data) |
Description of the input | IO-Link switching and communication cable |
Number of Inputs | 1 |
Connection Method | Screw connection |
Connection technology | 3-conductor |
Number of Ports | 1 |
Port Type | Class A |
Relay: Enabling current path (13/14, 23/24)
Output description | safety-related N/O contacts |
Output description | 2 NO contacts each in series, without delay, floating |
Number of Outputs | 2 (undelayed) |
Contact switching type | 2 enabling current paths |
Contact Material | AgSnO2 |
Switching voltage | min. 12 V AC/DC |
Switching voltage | max. 250 V AC/DC (Observe the load curve) |
Switching capacity | min. 60 mW |
Inrush Current | min. 3 mA |
Inrush Current | max. 6 A |
Switching capacity in accordance with IEC 60947-5-1 | 4 A (24 V (DC13)) |
Switching capacity in accordance with IEC 60947-5-1 | 5 A (250 V (AC15)) |
Limiting Continuous Current | 6 A |
Sq. Total current | 72 A2 (observe derating) |
Switching frequency | 0.5 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 6 A gL/gG |
Output fuse | 4 A gL/gG (for low-demand applications) |
Signal: M1
Output description | PNP |
Output description | non-safety-related |
Number of Outputs | 1 |
Voltage | approx. 22 V DC (Us - 2 V) |
Current | max. 100 mA |
Maximum Inrush Current | 500 mA (Δt = 1 ms at Us) |
Protective circuit | Suppressor diode |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Screw connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Signaling
Status display | 5x LED green |
Operating voltage display | 1 x green, yellow, red LED |
Dimensions
Width | 17.5 mm |
Height | 112.2 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide |
Safety data
Stop category | 0 |
Safety data: EN ISO 13849
Category | 4 |
Performance level (PL) | e (4 A DC13; 5 A AC15; 8760 switching cycles/year) |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 |
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL) | 3 |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -25 °C ... 60 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (Operation) | 10 Hz ... 150 Hz, 2g |
CE
Identification | CE-compliant |
Air clearances and creepage distances between the power circuits
Standards/regulations | DIN EN 60947-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | See derating curve |
Mounting Position | vertical or horizontal |
Accessories
Why Proax for Phoenix Contact 2702901?
Proax is an authorized distributor of Phoenix Contact 2702901 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended