Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2700575
Weight
0.158 kg
Series PSR-MC

PSR-MC62-2NO-1DO-24DC-SP - Safety relays

Safety relay for two-hand controls in accordance with ISO 13851 type IIIC, up to SIL 3, Cat. 4, PL e, synchronous activation monitoring < 0.5 s, 2 enabling current paths, US = 24 V DC, plug-in Push-in terminal block

  • Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061
  • Type IIIC in accordance with ISO 13851
  • Low housing width of just 12.5 mm
  • 2 enabling current paths, 1 digital signal output
  • Automatic activation
Technical Specifications

Product properties

Product familyPSRmini
ApplicationTwo-hand control
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Times

Typical response time< 50 ms
Typical release time< 10 ms (when controlled via S12/S22)
Typical release time< 5 ms (when interrupted via A1; applicative deactivation via A1/A2 is not permitted)
Restart time< 2 s (Boot time)
Recovery time< 500 ms

Electrical properties

Maximum power dissipation for nominal condition5.09 W (at US = 30 V, IL² = 72 A²)
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated Insulation Voltage250 V AC
Rated surge voltage/insulationBasic insulation 4 kV between all current paths and housing
Rated surge voltage/insulationSafe isolation, reinforced insulation 6 kV:between (A1, A2, S11, S12, S21, S22, S35, M1) and enabling current path (13/14)between (A1, A2, S11, S12, S21, S22, S35, M1) and enabling current path (23/24)between enabling current paths

Supply

DesignationA1/A2
Rated control circuit supply voltage US19.2 V DC ... 30 V DC
Rated control circuit supply voltage US24 V DC -20 % / +25 %
Rated control supply current IStyp. 40 mA
Power consumption at UStyp. 0.96 W
Inrush Currenttyp. 20 A (Δt = 10 µs at Us)
Filter time10 ms (For the logic. At A1 in the event of voltage dips at Us )
Protective circuitSurge protection; Suppressor diode
Protective circuitProtection against polarity reversal for rated control circuit supply voltage

Digital: Sensor circuit (S12, S22)

Description of the inputsafety-related sensor inputs
Number of Inputs2
Inrush Current< 10 mA (with Us/Ix to S12/S22)
Concurrence< 0.5 s
Max. permissible overall conductor resistance150 Ω
Current consumption< 4.2 mA (with Us/Ix to S12/S22)

Digital: Feedback circuit (S35)

Description of the inputnon-safety-related
Number of Inputs1
Inrush Current< 5.5 mA (typically with US)
Max. permissible overall conductor resistance150 Ω
Voltage at input/start and feedback circuit24 V DC -20 % / +25 %
Current consumption< 5.1 mA (typically with US)

Relay: Enabling current paths (13/14, 23/24)

Output descriptionsafety-related N/O contacts
Number of Outputs2 (undelayed)
Contact switching type2 enabling current paths
Contact MaterialAgSnO2 (enabling current path)
Switching voltagemin. 12 V AC/DC
Switching voltagemax. 250 V AC/DC (Observe the load curve)
Switching capacitymin. 60 mW
Inrush Currentmin. 3 mA
Inrush Currentmax. 6 A
Limiting Continuous Current6 A (observe derating)
Sq. Total current72 A2 (observe derating)
Switching frequency1 Hz
Mechanical service life10x 106 cycles
Output fuse6 A gL/gG (N/O contact)

Signal: M1

Output descriptionPNP
Output descriptionnon-safety-related
Number of Outputs1 (digital, PNP)
Voltage22 V DC (Us - 2 V)
Currentmax. 100 mA
Maximum Inrush Current500 mA (Δt = 1 ms at Us)
Short-circuit protectionYes

Connection technology

pluggableyes

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG24 ... 16
Stripping length8 mm

Signaling

Status display5 x bi-color LED

Dimensions

Width12.5 mm
Height116.6 mm
Depth114.5 mm

Material specifications

Coloryellow
Housing MaterialPolyamide

Safety data

Stop category0
Type classIIIC

Safety data: EN ISO 13849

Category4 (4 A DC13; 5 A AC15; 8760 switching cycles/year)
Performance level (PL)e (4 A DC13; 5 A AC15; 8760 switching cycles/year)

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)3 (4 A DC13; 5 A AC15; 8760 switching cycles/year)

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3 (4 A DC13; 5 A AC15; 8760 switching cycles/year)

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-35 °C ... 60 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

CE

IdentificationCE-compliant

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 50178

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsSee derating curve
Mounting Positionvertical or horizontal

Why Proax for Phoenix Contact PSR-MC62-2NO-1DO-24DC-SP?

Proax is an authorized distributor of Phoenix Contact PSR-MC62-2NO-1DO-24DC-SP and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPSRMC622NO1DO24DCSP
Pack Size1
Recommended

Available for order