QUINT4-CHARGER/1AC/24DC/10 - Battery charger
Battery charger QUINT CHARGER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 10 A
Technical Specifications
Product properties
| Product family | QUINT CHARGER |
| MTBF (IEC 61709, SN 29500) | > 500000 h (230 V AC, at 40 °C) |
Insulation characteristics
| Protection class | I |
| Degree of pollution | 2 |
Electrical properties
| Number of phases | 1.00 |
AC operation
| Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
| Derating | < 90 V AC (2.5 %/V) |
| Frequency range (fN) | 50 Hz ... 60 Hz ±10 % |
| Current consumption | 2.7 A (100 V AC) |
| Current consumption | 1.2 A (240 V AC) |
| Input fuse | 6.3 A (internal (device protection), slow-blow) |
| Recommended breaker for input protection | 10 A ... 16 A (AC: Characteristic B, C, D, K, or comparable) |
DC operation
| Input voltage range | 110 V DC ... 250 V DC |
| Current consumption | 2.4 A (110 V DC) |
| Current consumption | 1.1 A (250 V DC) |
Digital Control (configurable)
| Designation | Remote / Service |
Output data
| Efficiency | 89 % |
| Efficiency | 91 % |
| Nominal Output Voltage | 24 V DC |
| Setting range of the output voltage (USet) | 19.2 V DC ... 28.6 V DC |
| Nominal output current (IN) | 10 A |
| Residual ripple | < 20 mVPP |
| Short-circuit-proof | yes |
| No-load proof | yes |
| Output Power | 240 W |
| Maximum no-load power dissipation | < 4 W (for 230 V AC) |
| Power loss nominal load max. | < 35 W (for 230 V AC) |
| Connection in parallel | no |
| Connection in series | No |
Signal: UIn OK
| Output Voltage | 24 V DC |
| Continuous load current | 20 mA |
| Signal ground SGnd | Reference ground signal contacts |
Signal: Bat.-Voltage OK
| Output Voltage | 24 V DC |
| Continuous load current | 20 mA |
| Signal ground SGnd | Reference ground signal contacts |
Signal: Alarm
| Output Voltage | 24 V DC |
| Continuous load current | 20 mA |
| Signal ground SGnd | Reference ground signal contacts |
Energy storage
| Nominal voltage UN | 24 V DC |
| Charging voltage | max. 32 V DC |
| Charging current | typ. 10 A |
| Nominal capacity range | 7 Ah ... 300 Ah |
| Battery technology | VRLA, VRLA-WTR, LI-ION (LiFePO4) |
| Charge characteristic curve | IU |
Input
| Connection Method | Screw connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² |
| Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 2.5 mm² |
| Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
| Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 6.5 mm |
| Tightening torque, min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
Output
| Connection Method | Screw connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² |
| Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 2.5 mm² |
| Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
| Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 6.5 mm |
| Tightening torque, min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
Signal
| Connection Method | Push-in connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² |
| Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 1.5 mm² |
| Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
| Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Interfaces
| Interface | MINI-USB type B |
Signal output: Transistor output, active
| Signalization designation | UIn OK |
| Status display | Green LED |
| Signalization designation | Bat.-Voltage OK |
| Status display | Green LED |
| Signalization designation | Alarm |
| Status display | LED red |
Signal output
| Signalization designation | Reference potential for the signal inputs and outputs |
Dimensions
| Width | 60 mm |
| Height | 130 mm |
| Depth | 126 mm |
Installation dimensions
| Installation distance right/left | 0 mm / 0 mm |
| Installation distance top/bottom | 50 mm / 50 mm |
Alternative assembly
| Width | 123 mm |
| Height | 130 mm |
| Depth | 63 mm |
Material specifications
| Housing Material | Metal |
| Hood version | High-grade steel plate |
| Side element version | Aluminum |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | ≤ 4000 m (> 2000 m, observe derating) |
| Climatic class | 3K3 (EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (At +25°C, non-condensing) |
| Shock | 30g, 18 ms in accordance with IEC 60068-2-27 |
| Vibration (Operation) | 2 Hz ... 15 Hz, ±2.5 mm amplitude; 15 Hz ... 150 Hz, 2.3g |
Approvals
| UL approvals | UL Listed UL 61010-1 |
| UL approvals | UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C |
UL
| Identification | UL Listed UL 61010 |
EMC data
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| Interference emission | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
| Noise immunity | Immunity in accordance with EN 61000-6-2 (industrial) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Conducted noise emission | EN 61000-6-3 (Class B) |
| Noise emission | EN 61000-6-3 (Class B) |
Harmonic currents
| Frequency Range | 0 kHz ... 2 kHz |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 6 kV (Test Level 3) |
| Discharge in air | 8 kV (Test Level 3) |
| Comments | Criterion A |
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 |
| Frequency Range | 80 MHz ... 1 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Comments | Criterion A |
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 |
| Input | 2 kV (Test Level 3 - asymmetrical) |
| Output | 1 kV (Test Level 2 - asymmetrical) |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Comments | Criterion B |
Surge voltage load (surge)
| Standards/regulations | EN 61000-4-5 |
| Input | 1 kV (Test Level 2 - symmetrical) |
| Input | 2 kV (Test Level 3 - asymmetrical) |
| Output | 0.5 kV (Test Level 1 - symmetrical) |
| Output | 1 kV (Test Level 1 - asymmetrical) |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Comments | Criterion B |
Conducted interference
| Standards/regulations | EN 61000-4-6 |
| I/O/S | asymmetrical |
| Frequency Range | 0.15 MHz ... 80 MHz |
| Comments | Criterion A |
| Voltage | 10 V (Test Level 3) |
Criteria
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
| Standard – Safety extra-low voltage | IEC 61010 (SELV) / (PELV) |
| Standard - Safe isolation | DIN VDE 0100-410 |
| Standard - safety for equipment for measurement, control, and laboratory use | IEC 61010-1 |
Overvoltage category
| EN 61010-1 | II |
Mounting
| Mounting Type | DIN rail mounting |
Why Proax for Phoenix Contact 2907990?
Proax is an authorized distributor of Phoenix Contact 2907990 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
QUINT4-CAP/24DC/5/4KJ - QUINT capacity module, with maintenance-free energy storage based on double-layer capacitor, DIN rail mounting, input: 24 V DC, output: 24 V DC / 5 A / 4 kJ incl. mounted UTA 107 universal DIN rail adapter. The “POWER MANAGEMENT SUITE” software (Item No. 1252232) available in the download area can be used for configuration.
QUINT4-CAP/24DC/10/8KJ - QUINT capacity module, with maintenance-free energy storage based on double-layer capacitor, DIN rail mounting, input: 24 V DC, output: 24 V DC / 10 A / 8 kJ incl. mounted UTA 107 universal DIN rail adapter. The “POWER MANAGEMENT SUITE” software (Item No. 1252232) available in the download area can be used for configuration.