Official Distributor
SKU
Weight
0.6 kg
Series QUINT4-ORING
QUINT4-ORING/12-24DC/2X10/2X10 - Module de redondance
Module de redondance actif QUINT ORING avec découplage MOSFET, ACB Technology, Montage sur rail DIN, 12 V DC ... 24 V DC, 2x 10 A, 2x 10 A
- Autonomie de la solution redondante jusqu'à deux fois plus élevée grâce à la répartition équilibrée de la charge
- Economie d'énergie
- Surveillance permanente de la redondance
- Redondance constante jusqu'à la charge
Technical Specifications
Input data
Nominal input voltage range | 12 V DC ... 24 V DC |
Input voltage range | 8 V DC ... 29.5 V DC |
Voltage type of supply voltage | DC |
Nominal input current (IN) | 2x 10 A |
Static Boost (IStat.Boost) | 2x 12.5 A |
Dynamic Boost (IDyn.Boost) | 2x 20 A (5 s) |
Selective Fuse Breaking (ISFB) | 2x 60 A (15 ms) |
Reverse polarity protection | < yes60 V DC |
Intended listed circuit breaker for input protection | 60 V DC |
Intended listed circuit breaker for input protection | 16 A (Characteristic B, C) |
Voltage drop, input/output | typ. 0.1 V (IOUT = 10 A) |
Output data
Efficiency | typ. 98.5 % (12 V DC) |
Efficiency | typ. 99 % (24 V DC) |
Nominal Output Voltage | UIn - 0.1 V |
Nominal output current (IN) | 2x 10 A |
Nominal output current (IN) | 1x 20 A |
Static Boost (IStat.Boost) | 2x 12.5 A |
Static Boost (IStat.Boost) | 1x 25 A |
Dynamic Boost (IDyn.Boost) | 2x 20 A (5 s) |
Dynamic Boost (IDyn.Boost) | 1x 40 A (5 s) |
Selective Fuse Breaking (ISFB) | 2x 60 A (15 ms) |
Selective Fuse Breaking (ISFB) | 1x 120 A (15 ms) |
Connection in series | No |
Feedback voltage resistance | ≤ 32 V DC |
Protection against overvoltage at the output (OVP) | < 32 V DC |
Power loss nominal load max. | 4.08 W (IOUT = 40 A) |
Power loss nominal load max. | 4.25 W (IOUT = 20 A) |
Signal relay 13/14
Connection labeling | 3.1, 3.2 |
Switch contact (floating) | floating |
Maximum contact load | 30 V DC |
Maximum contact load | 100 mA |
Signal option | Redundancy OK |
Signal relay 23/24
Connection labeling | 3.3, 3.4 |
Switch contact (floating) | floating |
Maximum contact load | 30 V DC |
Maximum contact load | 100 mA |
Signal option | ACB OK |
Input
Position | 1.x |
Conductor connection
Connection Method | Screw connection |
rigid | 0.2 mm² ... 6 mm² |
flexible | 0.2 mm² ... 4 mm² |
flexible with ferrule without plastic sleeve | 0.25 mm² ... 4 mm² |
flexible with ferrule with plastic sleeve | 0.25 mm² ... 4 mm² |
rigid (AWG) | 24 ... 10 |
Stripping length | 8 mm |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Drive form screw head | Slotted L |
Output
Position | 2.x |
Conductor connection
Connection Method | Screw connection |
rigid | 0.2 mm² ... 6 mm² |
flexible | 0.2 mm² ... 4 mm² |
flexible with ferrule without plastic sleeve | 0.25 mm² ... 4 mm² |
flexible with ferrule with plastic sleeve | 0.25 mm² ... 4 mm² |
rigid (AWG) | 24 ... 10 |
Stripping length | 8 mm |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Drive form screw head | Slotted L |
Signal
Position | 3.x |
Conductor connection
Connection Method | Push-in connection |
rigid | 0.2 mm² ... 1 mm² |
flexible | 0.2 mm² ... 1.5 mm² |
flexible with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
flexible with ferrule with plastic sleeve | 0.2 mm² ... 0.75 mm² |
rigid (AWG) | 24 ... 16 |
Stripping length | 8 mm |
LED signaling
Types of signaling | DC OK (green) |
Signal threshold | Redundancy OK (LED lights up green) |
Signal threshold | I < In (LED lights up green) |
Signal threshold | ACB OK (LED lights up green) |
Signal threshold | ACB OK (sources are slightly asymmetrical) (LED lights up green and yellow) |
Signal threshold | Sources are asymmetrical (LED flashing red) |
Electrical properties
Insulation voltage input, output / housing | 600 V AC |
Insulation voltage input, output / housing | 850 V DC |
Product properties
Product family | QUINT ORING |
MTBF (IEC 61709, SN 29500) | > 2101000 h (25 °C) |
MTBF (IEC 61709, SN 29500) | > 1247000 h (40 °C) |
MTBF (IEC 61709, SN 29500) | > 599000 h (60 °C) |
Environmental protection directive | RoHS Directive 2011/65/EU |
Environmental protection directive | WEEE |
Environmental protection directive | Reach |
LED | yes |
Insulation characteristics
Protection class | III |
Degree of pollution | 2 |
Life expectancy (electrolytic capacitors)
Current | 20 A |
Temperature | 40 °C |
Time | 295000 h |
Additional text | 12 V DC |
Current | 20 A |
Temperature | 40 °C |
Time | 240000 h |
Additional text | 24 V DC |
Item dimensions
Width | 39 mm |
Height | 130 mm |
Depth | 132 mm |
Depth | 125 mm (Device depth (DIN rail mounting)) |
Item dimensions with alternative mounting
Width | 122 mm |
Height | 130 mm |
Depth | 36 mm |
Installation dimensions
Installation distance right/left | 5 mm / 5 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Mounting Position | horizontal DIN rail NS 35, EN 60715 |
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
Housing Material | Metal |
Type of housing | Aluminum (AlMg3) |
Hood version | Galvanized sheet steel, free from chrome (VI) |
Side element version | Aluminum |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | 5000 m |
Max. permissible relative humidity (operation) | ≤ 100 % (at 25 °C, non-condensing) |
Shock (operation) | 18 ms, 30g, per spatial direction (IEC 60068-2-27) |
Vibration (Operation) | < 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6) |
Vibration (Operation) | 15 Hz ... 150 Hz, 2.3g, 90 min. |
Electrical safety
Standard designation | Electrical safety (of control and regulation devices) |
Standards/specifications | IEC 61010-1 |
Protective extra-low voltage
Standard designation | Protective extra-low voltage |
Standards/specifications | EN 61010-1 (SELV) |
Standard designation | Protective extra-low voltage |
Standards/specifications | IEC 61010-2-201 (PELV) |
Shipbuilding
Identification | DNV |
UL
Identification | UL Listed UL 61010-1 |
Identification | UL Listed UL 61010-2-201 |
Identification | UL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) |
CSA
Identification | CAN/CSA-C22.2 No. 61010-1-12 |
Identification | CAN/CSA C22.2 No. 61010-2-201:18 |
ATEX
Identification | II 3 G Ex ec nC IIC T4 Gc |
Identification | DEKRA 22ATEX0104 X |
IECEx
Identification | Ex ec nC IIC T4 Gc |
Identification | IECEx DEK 22.0089X |
UKEX
Identification | II 3 G Ex ec nC IIC T4 Gc |
Identification | DEKRA 22UKEX6029X |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conducted noise emission | EN 55016 |
Conducted noise emission | EN 61000-6-3 (Class B) |
Noise emission | Additional basic standard EN 61000-6-5 (immunity in power station) |
Noise emission | EN 55016 |
Noise emission | EN 61000-6-3 (Class B) |
DNV GL conducted interference | Class B |
Additional text | Bridge and deck area |
DNV GL noise radiation | Class B |
Additional text | Bridge and deck area |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 3) |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 1 GHz |
Test field strength | 20 V/m (Test Level 3) |
Frequency Range | 1 GHz ... 6 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) |
Comments | Criterion A |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 0.5 kV (Test Level 2 - symmetrical) |
Input | 1 kV (Test Level 2 - asymmetrical) |
Output | 0.5 kV (Test Level 2 - symmetrical) |
Output | 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
I/O/S | asymmetrical |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Why Proax for Phoenix Contact 1088206?
Proax is an authorized distributor of Phoenix Contact 1088206 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended