SKU
MPN
QUINT4-PS/48-110DC/24DC/2.5/PT
Weight
0.3 kg
This product is Not Cancellable/Not Returnable
Series QUINT4-PS

QUINT4-PS/48-110DC/24DC/2.5/PT - DC/DC converter

Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, input: 48 V DC - 110 V DC, output: 24 V DC / 2.5 A

  • Most powerful output side: easy system expansion, reliable heavy load startup and miniature circuit breaker tripping
  • Most comprehensive signaling: preventive function monitoring reports critical operating states before errors occur
  • Free selection between Push-in and screw connection
Technical Specifications

Input data

Nominal input voltage range48 V DC ... 110 V DC
Input voltage range48 V DC ... 110 V DC -37,5 % ...+40 %
Wide-range inputyes
Electric strength, max.160 V DC (60 s)
Inrush Currenttyp. 8 A
Inrush current integral (I2t)typ. 0.1 A2s
Inrush current limitation8 A
Mains buffering timetyp. 14 ms (48 V DC)
Mains buffering timetyp. 17 ms (110 V DC)
Current consumptiontyp. 1.7 A (48 V DC)
Current consumptiontyp. 0.75 A (110 V DC)
Switch-on time< 1 s
Input fuse4 A (slow-blow, internal)
Recommended breaker for input protection10 A ... 16 A (Characteristic B, C, D, K or comparable)

Output data

Efficiencytyp. 93.7 % (110 V DC)
Output characteristicU/I Advanced
Output characteristicSmart HICCUP
Output characteristicFUSE MODE
Nominal Output Voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity)
Nominal output current (IN)2.5 A
Static Boost (IStat.Boost)3.125 A (≤ 40 °C)
Dynamic Boost (IDyn.Boost)5 A (≤ 60 °C (4.9 s))
Short-circuit-proofyes
No-load proofyes
Derating> 60 °C (2.5%/K of POut nom.)
Output power (PN)60 W
Output power (PStat. Boost)75 W
Output power (PDyn. Boost)120 W
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 32 V DC
Residual ripple< 20 mVPP
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Rise time< 1 s (UOUT (10 % ... 90 %))
Connection in seriesyes
Maximum no-load power dissipation< 2.2 W
Power loss nominal load max.< 4.8 W
Connection in parallelyes, for redundancy and increased capacity

Signal (configurable)

Digital0 V DC
Digital24 V DC
Digital22 mA
Default24 V DC
Default22 mA
Default24 V DC for UOut > 0.9 x USet

Input

Position1.x

Conductor connection

Connection MethodPush-in connection
rigid0.2 mm² ... 2.5 mm²
flexible0.25 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve0.25 mm² ... 2.5 mm²
rigid (AWG)22 ... 14
Stripping length10 mm

Output

Position2.x

Conductor connection

Connection MethodPush-in connection
rigid0.5 mm² ... 2.5 mm²
flexible0.5 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve0.5 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve0.5 mm² ... 2.5 mm²
rigid (AWG)20 ... 14
Stripping length10 mm

Signal

Position3.x

Conductor connection

Connection MethodPush-in connection
rigid0.2 mm² ... 2.5 mm²
flexible0.25 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve0.25 mm² ... 2.5 mm²
rigid (AWG)24 ... 14
Stripping length10 mm

LED signaling

Signal threshold> PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting)
Signal threshold> 0.9 x USet (LED lights up green)
Signal threshold< 0.9 x USet (LED flashes green)

Electrical properties

Number of phases1.00
Insulation voltage input/output2.6 kV DC (type test)
Insulation voltage input/output1.2 kV DC (routine test)
Switching frequency130.00 kHz ... 130.00 kHz (Auxiliary converter stage)
Switching frequency70.00 kHz ... 250.00 kHz (Main converter stage)

Product properties

Product familyQUINT POWER
MTBF (IEC 61709, SN 29500)> 1200000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 618000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 230000 h (60 °C)

Insulation characteristics

Protection classII
Degree of pollution2

Life expectancy (electrolytic capacitors)

Current2.5 A
Temperature40 °C
Time171000 h
Additional text24 V DC
Current2.5 A
Temperature30 °C
Time343000 h
Additional text24 V DC

Item dimensions

Width32 mm
Height106 mm
Depth90 mm

Item dimensions with alternative mounting

Width90 mm
Height106 mm
Depth32 mm

Installation dimensions

Installation distance right/left (active)15 mm / 15 mm (POut ≥50% )
Installation distance right/left (passive)5 mm / 5 mm (POut ≥50% )
Installation distance right/left (active, passive)0 mm / 0 mm (POut ≤50 %)
Installation distance top/bottom (active)30 mm / 30 mm (POut ≥50% )
Installation distance top/bottom (passive)30 mm / 30 mm (POut ≥50% )
Installation distance top/bottom (active, passive)30 mm / 30 mm (POut ≤50 %)

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
With protective coatingNo

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing MaterialPlastic
Type of housingPolycarbonate (PC), UL 94 V0

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 5000 m (> 2000 m, observe derating)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)< 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)

Overvoltage category

EN 61010-1II (≤ 5000 m)
EN 62477-1III (≤ 2000 m)

Safety for measurement, control, and laboratory equipment

Standard designationElectrical safety (of control and regulation devices)
Standards/specificationsIEC 61010-1

Protective extra-low voltage

Standard designationProtective extra-low voltage
Standards/specificationsIEC 61010-1 (SELV)

Mains voltage dips

Standard designationMains variation/undervoltage
Standards/specificationsEN 61000-4-29

Approvals

SIQCB-Scheme (IEC 61010-1, IEC 61010-2-201)
UL approvalsUL Listed UL 61010-1
UL approvalsUL Listed UL 61010-2-201
UL approvalsANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

UL

IdentificationUL Listed UL 61010-1
IdentificationCAN/CSA C22.2 No. 61010-1-12
IdentificationUL Listed UL 61010-2-201
IdentificationCAN/CSA C22.2 No. 61010-2-201:18
IdentificationUL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)

CB scheme

IdentificationIEC 61010-1
IdentificationIEC 61010-2-201

Shipbuilding

IdentificationDNV GL

EMC data

EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
EMC requirements, power plantEN 61850-3
EMC requirements, power plantEN 61000-6-5
Conducted noise emissionEN 55016
Conducted noise emissionEN 61000-6-3 (Class B)
Noise emissionAdditional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Noise emissionEN 55016
Noise emissionEN 61000-6-3 (Class B)
DNV GL conducted interferenceClass B
Additional textBridge and deck area
DNV GL noise radiationClass B
Additional textBridge and deck area

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength20 V/m (Test Level 3)
Frequency Range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input2 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 4 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion B

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input0.5 kV (Test Level 3 - symmetrical)
Input1 kV (Test Level 3 - asymmetrical)
Output0.5 kV (Test Level 2 - symmetrical)
Output1 kV (Test Level 1 - asymmetrical)
Signal0.5 kV (Test Level 2 - symmetrical)
Signal1 kV (Test Level 1 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Power frequency magnetic field

Standards/regulationsEN 61000-4-8
Frequency16.67 Hz
Frequency50 Hz
Frequency60 Hz
Test field strength100 A/m
Additional text60 s
CommentsCriterion A
Frequency50 Hz
Frequency60 Hz
Frequency Range50 Hz ... 60 Hz
Test field strength1 kA/m
Additional text3 s
Frequency0 Hz
Test field strength300 A/m
Additional textDC, 60 s

Voltage dips

Standards/regulationsEN 61000-4-29
Voltage48 V DC
Voltage dip70 %
Number of periods0.5 / 1 / 25 periods
Time100 ms
Additional textTest Level 2
CommentsCriterion A
Voltage dip40 %
Number of periods5 / 10 / 50 periods
Time100 ms
Additional textTest Level 2
CommentsCriterion B
Voltage dip0 %
Number of periods0.5 / 1 / 5 / 50 periods
Time50 ms
Additional textTest Level 2
CommentsCriterion B

Pulse-shape magnetic field

Standards/regulationsEN 61000-4-9
Test field strength1000 A/m
CommentsCriterion A

Asymmetrical conducted disturbance variables

Standards/regulationsEN 61000-4-16
Test level 115 Hz 150 Hz (Test Level 3)
Voltage10 V 1 V (Permanent)
Test level 2150 Hz 1.5 kHz (Test Level 3)
Voltage1 V
Test level 31.5 kHz 15 kHz (Test Level 3)
Voltage1 V 10 V
Test level 415 kHz 150 kHz (Test Level 3)
Voltage10 V
Test level 516.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
Voltage10 V (Permanent)
Test level 60 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
Voltage100 V (1 s)
CommentsCriterion A

Alternating component of direct voltage

Standards/regulationsEN 61000-4-17
Alternating component10 % (UN)
Frequency50 Hz
Frequency100 Hz
Frequency150 Hz
Frequency300 Hz
CommentsCriterion A

Attenuated oscillating wave

Standards/regulationsEN 61000-4-18
Input, output (test level 1)1 MHz (Test Level 2 - symmetrical)
Voltage0.5 kV
Input, output (test level 2)1 MHz (Test Level 2 - asymmetrical)
Voltage1 kV
Signals (test level 1)1 MHz (Test Level 2 - symmetrical)
Voltage0.5 kV
Signals (test level 2)1 MHz (Test Level 2 - asymmetrical)
Voltage1 kV
CommentsCriterion A

Attenuated oscillating magnetic field

Standards/regulationsEN 61000-4-10
Test field strength100 A/m
Test level 1100 kHz
Test field strength100 A/m
Test level 21 MHz
CommentsCriterion A

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Why Proax for Phoenix Contact 1066708?

Proax is an authorized distributor of Phoenix Contact 1066708 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability