Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
QUINT4-PS/24DC/24DC/10/PT/CO
Weight
1.043 kg
This product is Not Cancellable/Not Returnable
Series QUINT4-PS

QUINT4-PS/24DC/24DC/10/PT/CO - DC/DC converter

Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 24 V DC, output: 24 V DC / 10 A

  • Most powerful output side: easy system expansion, reliable heavy load startup and miniature circuit breaker tripping
  • Most comprehensive signaling: preventive function monitoring reports critical operating states before errors occur
  • Protective coating and ATEX/IECEx approval
Technical Specifications

Input data

Nominal input voltage range24 V DC
Input voltage range24 V DC -25 % ... +40 %
Wide-range inputno
Electric strength, max.35 V DC (60 s)
Inrush Currenttyp. 1.5 A
Inrush current integral (I2t)< 0.02 A2s
Inrush current limitation1.5 A (after 1 ms)
Mains buffering timetyp. 11 ms (24 V DC)
Current consumption13.8 A (24 V DC)
Typical response time300 ms (from SLEEP MODE)
Switch-on time< 1 s
Input fuse30 A (slow-blow, internal)
Recommended breaker for input protection16 A ... 32 A (Characteristic B, C, D, K or comparable)

Signal Remote (configurable)

Connection labeling3.3 +
FunctionOutput power ON/OFF (remote)
DefaultOutput power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)

Output data

Efficiencytyp. 93.3 % (24 V DC)
Output characteristicU/I Advanced
Output characteristicSmart HICCUP
Output characteristicFUSE MODE
Nominal Output Voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity)
Nominal output current (IN)10 A
Static Boost (IStat.Boost)12.5 A
Dynamic Boost (IDyn.Boost)20 A (5 s)
Selective Fuse Breaking (ISFB)60 A (15 ms)
Magnetic circuit breaker trippingA1...A6 / B2...B6 / C1...C3 / Z1...Z6
Short-circuit-proofyes
No-load proofyes
Output power (PN)240 W
Output power (PStat. Boost)300 W
Output power (PDyn. Boost)480 W (5 s)
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 30 V DC
Residual ripple< 50 mVPP
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Rise time< 1 s (UOUT (10 % ... 90 %))
Connection in seriesyes
Maximum no-load power dissipation< 5 W
Power loss nominal load max.< 16 W
Power dissipation SLEEP MODE< 2 W
Connection in parallelyes, for redundancy and increased capacity

Signal Out 1 (configurable)

Connection labeling3.5 +
Digital0 V DC
Digital24 V DC
Digital20 mA
Signal optionOutput voltage
Signal optionOutput current
Signal optionOutput power
Signal optionOperating hours
Signal optionEarly warning of high temperatures
Signal optionOVP voltage limitation active
DefaultUIN input voltage OK

Signal Out 2 (configurable)

Connection labeling3.6 +
Digital0 V DC
Digital24 V DC
Digital20 mA
DefaultOutput power
Signal optionOutput voltage
Signal optionOutput current
Signal optionOperating hours
Signal optionEarly warning of high temperatures
Signal optionOVP voltage limitation active
Analog4 mA ... 20 mA ±5 % (Load ≤400 Ω)
Signal optionOutput voltage
Signal optionOutput current
Signal optionOutput power

Signal relay 13/14 (configurable)

Connection labeling3.1, 3.2
Switch contact (floating)floating
Maximum contact load24 V DC
Maximum contact load1 A
Maximum contact load30 V AC
Maximum contact load0.5 A
DefaultOutput voltage
Signal optionOutput current
Signal optionOutput power
Signal optionOperating hours
Signal optionEarly warning of high temperatures
Signal optionOVP voltage limitation active
Signal optionUIN input voltage OK

Signal ground SGnd

Connection labeling3.4 +
FunctionSignal ground
Reference potentialto OUT1, OUT2, REM

Input

Position1.x

Conductor connection

Connection MethodPush-in connection
rigid0.2 mm² ... 6 mm²
flexible0.2 mm² ... 6 mm²
flexible with ferrule without plastic sleeve0.2 mm² ... 4 mm²
flexible with ferrule with plastic sleeve0.2 mm² ... 4 mm²
rigid (AWG)24 ... 10
Stripping length10 mm

Output

Position2.x

Conductor connection

Connection MethodPush-in connection
rigid0.2 mm² ... 6 mm²
flexible0.2 mm² ... 6 mm²
flexible with ferrule without plastic sleeve0.2 mm² ... 4 mm²
flexible with ferrule with plastic sleeve0.2 mm² ... 4 mm²
rigid (AWG)24 ... 10
Stripping length10 mm

Signal

Position3.x

Conductor connection

Connection MethodPush-in connection
rigid0.2 mm² ... 1 mm²
flexible0.2 mm² ... 1.5 mm²
flexible with ferrule without plastic sleeve0.2 mm² ... 1.5 mm²
flexible with ferrule with plastic sleeve0.2 mm² ... 0.75 mm²
rigid (AWG)24 ... 16
Stripping length8 mm

LED signaling

Types of signalingLED
Types of signalingFloating signal contact
Types of signalingActive signal output Out1 (digital, configurable)
Types of signalingActive signal output Out2 (analog, configurable)
Types of signalingRemote contact
Types of signalingSignal ground SGnd
Signal threshold> 100 % (LED lights up yellow, output power > 240 W)
Signal threshold> 75 % (LED lights up green, output power > 180 W)
Signal threshold> 50 % (LED lights up green, output power > 120 W)
Signal threshold> 0.9 x USet (LED lights up green)
Signal threshold< 0.9 x USet (LED flashes green)
Signal threshold> 0.8 x UInNom (LED off)
Signal threshold< 0.8 x UInNom (LED lights up yellow)

Electrical properties

Number of phases1.00
Insulation voltage input/output4 kV DC (type test)
Insulation voltage input/output2 kV DC (routine test)
Switching frequency190.00 kHz ... 220.00 kHz (Auxiliary converter stage)
Switching frequency67.00 kHz ... 135.00 kHz (Main converter stage)

Product properties

Product familyQUINT POWER
MTBF (IEC 61709, SN 29500)> 1380000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 800000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 340000 h (60 °C)

Insulation characteristics

Protection classSpecial with SELV input and output
Degree of pollution2

Life expectancy (electrolytic capacitors)

Current5 A
Temperature40 °C
Time367721 h
Additional text24 V DC
Current10 A
Temperature40 °C
Time183860 h
Additional text24 V DC
Current10 A
Temperature30 °C
Time422400 h
Additional text24 V DC

Item dimensions

Width50 mm
Height130 mm
Depth125 mm

Item dimensions with alternative mounting

Width122 mm
Height130 mm
Depth53 mm

Installation dimensions

Installation distance right/left (active)15 mm / 15 mm (≤ 70 °C)
Installation distance right/left (passive)0 mm / 0 mm (≤ 70 °C)
Installation distance top/bottom (active)50 mm / 50 mm (≤ 70 °C)
Installation distance top/bottom (passive)50 mm / 50 mm (≤ 70 °C)

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
With protective coatingyes

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing MaterialMetal
Hood versionStainless steel X6Cr17
Side element versionAluminum

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 5000 m (> 2000 m, observe derating)
Climatic class3K3 (EN 60721)
Max. permissible relative humidity (operation)≤ 100 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)

Overvoltage category

EN 61010-1II
EN 62477-1III

Safety for measurement, control, and laboratory equipment

Standard designationElectrical safety (of control and regulation devices)
Standards/specificationsIEC 61010-1

Protective extra-low voltage

Standard designationProtective extra-low voltage
Standards/specificationsEN 61010-1 (SELV)
Standards/specificationsIEC 61010-2-201 (PELV)

Explosive atmospheres

Standard designationExplosive atmospheres
Standards/specificationsIEC 60079-0
Standards/specificationsIEC 60079-7
Standards/specificationsIEC 60079-11
Standards/specificationsIEC 60079-15

Mains voltage dips

Standard designationMains variation/undervoltage
Standards/specificationsEN 61000-4-29

UL

IdentificationUL Listed UL 61010-1
Identification II 3 G Ex ec ic nC IIC T4 Gc
IdentificationUL Listed UL 61010-2-201
IdentificationEx ec ic nC IIC T4 Gc
IdentificationUL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)

CSA

IdentificationCAN/CSA-C22.2 No. 61010-1-12
IdentificationCAN/CSA-IEC 61010-2-201:14

SIQ

IdentificationType tested (type approved)
IdentificationCB scheme (IEC 61010-1, IEC 61010-2-201)

Shipbuilding

IdentificationDNV GL
IdentificationABS

ATEX

IdentificationSIQ 21 ATEX 025 X
Identification II 3 G Ex ec ic nC IIC T4 Gc

IECEx

IdentificationIECEx SIQ 19.0001X
IdentificationEx ec ic nC IIC T4 Gc

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
EMC requirements, power plantIEC 61850-3
EMC requirements, power plantEN 61000-6-5
Conducted noise emissionEN 55016
Conducted noise emissionEN 61000-6-3 (Class B)
Noise emissionAdditional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Noise emissionEN 55016
Noise emissionEN 61000-6-3 (Class B)
DNV GL conducted interferenceClass B
Additional textBridge and deck area
DNV GL noise radiationClass B
Additional textBridge and deck area

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength20 V/m (Test Level 3)
Frequency Range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
Frequency Range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input4 kV (Test Level 3 - asymmetrical)
Output4 kV (Test Level 3 - asymmetrical)
Signal4 kV (Test Level 4 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input1 kV (Test Level 3 - symmetrical)
Input2 kV (Test Level 3 - asymmetrical)
Output1 kV (Test Level 3 - symmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 3 - asymmetrical)
CommentsCriterion A

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Power frequency magnetic field

Standards/regulationsEN 61000-4-8
Frequency16.7 Hz
Frequency50 Hz
Frequency60 Hz
Test field strength100 A/m
Additional text60 s
CommentsCriterion A
Frequency50 Hz
Frequency60 Hz
Frequency Range50 Hz ... 60 Hz
Test field strength1 kA/m
Additional text3 s
CommentsCriterion A
Frequency0 Hz
Test field strength300 A/m
Additional textDC, 60 s
CommentsCriterion A

Voltage dips

Standards/regulationsEN 61000-4-29
Voltage24 V DC
Voltage dip70 %
Time100 ms
Additional textTest Level 2
CommentsCriterion A
Voltage dip40 %
Time100 ms
Additional textTest Level 2
CommentsCriterion B
Voltage dip0 %
Time50 ms
Additional textTest Level 2
CommentsCriterion B

Pulse-shape magnetic field

Standards/regulationsEN 61000-4-9
Test field strength1000 A/m
CommentsCriterion A

Asymmetrical conducted disturbance variables

Standards/regulationsEN 61000-4-16
Test level 115 Hz 150 Hz (Test Level 4)
Voltage30 V 3 V
Test level 2150 Hz 1.5 kHz (Test Level 4)
Voltage3 V
Test level 31.5 kHz 15 kHz (Test Level 4)
Voltage0 V 3 V
Test level 415 kHz 150 kHz (Test Level 4)
Voltage30 V
Test level 516.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 4)
Voltage30 V (Permanent)
Test level 60 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 4)
Voltage300 V (1 s)
CommentsCriterion A

Alternating component of direct voltage

Standards/regulationsEN 61000-4-17
Alternating component10 % (UN)
Frequency50 Hz
Frequency100 Hz
Frequency150 Hz
Frequency300 Hz
CommentsCriterion A

Attenuated oscillating wave

Standards/regulationsEN 61000-4-18
Input, output (test level 1)100 kHz 1 MHz (Test Level 3 - symmetrical)
Voltage1 kV
Input, output (test level 2)100 kHz 1 MHz (Test Level 3 - asymmetrical)
Voltage2.5 kV
Input, output (test level 3)10 MHz (Test Level 3 - asymmetrical)
Voltage2 kV
Signals (test level 1)100 kHz 1 MHz (Test Level 2 - symmetrical)
Voltage1 kV
Signals (test level 2)100 kHz 1 MHz (Test Level 3 - asymmetrical)
Voltage2.5 kV
CommentsCriterion A

Attenuated oscillating magnetic field

Standards/regulationsEN 61000-4-10
Test field strength100 A/m
Test level 1100 kHz
Test field strength100 A/m
Test level 21 MHz
CommentsCriterion A

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Accessories

Why Proax for Phoenix Contact 2910133?

Proax is an authorized distributor of Phoenix Contact 2910133 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability