Official Distributor
SKU
Weight
1.068 kg
This product is Not Cancellable/Not Returnable
Series QUINT4-PS
QUINT4-PS/24DC/48DC/5/PT - Convertisseur DC/DC
Convertisseur DC/DC à découpage primaire, QUINT POWER, Montage sur rail DIN, SFB Technology (Selective Fuse Breaking), entrée: 24 V DC, sortie : 48 V DC / 5 A
- Côté sortie puissant : extension aisée des installations, démarrage fiable des charges lourdes et déclenchement des coupe-circuits automatiques
- Signalisation complète : surveillance préventive des fonctions, signalant tout état de fonctionnement critique avant l'apparition d'erreurs
- Commande avec configuration par défaut possible dès la première unité
Technical Specifications
Input data
Nominal input voltage range | 24 V DC |
Input voltage range | 24 V DC -25 % ... +40 % |
Wide-range input | no |
Electric strength, max. | 35 V DC (60 s) |
Inrush Current | typ. 1 A |
Inrush current integral (I2t) | < 0.01 A2s |
Inrush current limitation | 1 A (after 1 ms) |
Mains buffering time | typ. 16 ms (24 V DC) |
Current consumption | 13.8 A (24 V DC) |
Typical response time | 300 ms (from SLEEP MODE) |
Switch-on time | < 1 s |
Input fuse | 30 A (slow-blow, internal) |
Recommended breaker for input protection | 16 A ... 20 A (Characteristic B, C, D, K or comparable) |
Signal Remote (configurable)
Connection labeling | 3.3 + |
Function | Output power ON/OFF (remote) |
Default | Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd) |
Output data
Efficiency | typ. 94 % (24 V DC) |
Output characteristic | U/I Advanced |
Output characteristic | Smart HICCUP |
Output characteristic | FUSE MODE |
Nominal Output Voltage | 48 V DC |
Setting range of the output voltage (USet) | 48 V DC ... 56 V DC (> 48 V constant capacity) |
Nominal output current (IN) | 5 A |
Static Boost (IStat.Boost) | 6.25 A |
Dynamic Boost (IDyn.Boost) | 10 A (5 s) |
Selective Fuse Breaking (ISFB) | 30 A (15 ms) |
Magnetic circuit breaker tripping | A1...A6 / B2 / C1...C2 / Z1...Z6 |
Short-circuit-proof | yes |
No-load proof | yes |
Output power (PN) | 240 W |
Output power (PStat. Boost) | 300 W |
Output power (PDyn. Boost) | 480 W (5 s) |
Feedback voltage resistance | ≤ 60 V DC |
Protection against overvoltage at the output (OVP) | ≤ 60 V DC |
Residual ripple | < 50 mVPP |
Control deviation | < 3 % (change in load, static 10 % ... 90 %) |
Control deviation | < 3 % (change in load, static 10 % ... 90 %) |
Control deviation | < 3 % (change in load, static 10 % ... 90 %) |
Rise time | < 100 ms (UOUT (10 % ... 90 %)) |
Connection in series | yes |
Maximum no-load power dissipation | < 4 W |
Power loss nominal load max. | < 16 W |
Power dissipation SLEEP MODE | < 2 W |
Connection in parallel | yes, for redundancy and increased capacity |
Signal Out 1 (configurable)
Connection labeling | 3.5 + |
Digital | 0 V DC |
Digital | 24 V DC |
Digital | 20 mA |
Signal option | Output voltage |
Signal option | Output current |
Signal option | Output power |
Signal option | Operating hours |
Signal option | Early warning of high temperatures |
Signal option | OVP voltage limitation active |
Default | UIN input voltage OK |
Signal Out 2 (configurable)
Connection labeling | 3.6 + |
Digital | 0 V DC |
Digital | 24 V DC |
Digital | 20 mA |
Default | Output power |
Signal option | Output voltage |
Signal option | Output current |
Signal option | Operating hours |
Signal option | Early warning of high temperatures |
Signal option | OVP voltage limitation active |
Analog | 4 mA ... 20 mA ±5 % (Load ≤400 Ω) |
Signal option | Output voltage |
Signal option | Output current |
Signal option | Output power |
Signal relay 13/14 (configurable)
Connection labeling | 3.1, 3.2 |
Switch contact (floating) | floating |
Maximum contact load | 24 V DC |
Maximum contact load | 1 A |
Maximum contact load | 30 V AC |
Maximum contact load | 0.5 A |
Default | Output voltage |
Signal option | Output current |
Signal option | Output power |
Signal option | Operating hours |
Signal option | Early warning of high temperatures |
Signal option | OVP voltage limitation active |
Signal option | UIN input voltage OK |
Signal ground SGnd
Connection labeling | 3.4 + |
Function | Signal ground |
Reference potential | to OUT1, OUT2, REM |
Input
Position | 1.x |
Conductor connection
Connection Method | Push-in connection |
rigid | 0.2 mm² ... 6 mm² |
flexible | 0.2 mm² ... 6 mm² |
flexible with ferrule without plastic sleeve | 0.2 mm² ... 4 mm² |
flexible with ferrule with plastic sleeve | 0.2 mm² ... 4 mm² |
rigid (AWG) | 24 ... 10 |
Stripping length | 10 mm |
Output
Position | 2.x |
Conductor connection
Connection Method | Push-in connection |
rigid | 0.2 mm² ... 6 mm² |
flexible | 0.2 mm² ... 6 mm² |
flexible with ferrule without plastic sleeve | 0.2 mm² ... 4 mm² |
flexible with ferrule with plastic sleeve | 0.2 mm² ... 4 mm² |
rigid (AWG) | 24 ... 10 |
Stripping length | 10 mm |
Signal
Position | 3.x |
Conductor connection
Connection Method | Push-in connection |
rigid | 0.2 mm² ... 1 mm² |
flexible | 0.2 mm² ... 1.5 mm² |
flexible with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
flexible with ferrule with plastic sleeve | 0.2 mm² ... 0.75 mm² |
rigid (AWG) | 24 ... 16 |
Stripping length | 8 mm |
LED signaling
Types of signaling | LED |
Types of signaling | Floating signal contact |
Types of signaling | Active signal output Out1 (digital, configurable) |
Types of signaling | Active signal output Out2 (analog, configurable) |
Types of signaling | Remote contact |
Types of signaling | Signal ground SGnd |
Signal threshold | > 100 % (LED lights up yellow, output power > 240 W) |
Signal threshold | > 75 % (LED lights up green, output power > 180 W) |
Signal threshold | > 50 % (LED lights up green, output power > 120 W) |
Signal threshold | > 0.9 x USet (LED lights up green) |
Signal threshold | < 0.9 x USet (LED flashes green) |
Signal threshold | > 0.8 x UInNom (LED off) |
Signal threshold | < 0.8 x UInNom (LED lights up yellow) |
Electrical properties
Number of phases | 1.00 |
Insulation voltage input/output | 4 kV DC (type test) |
Insulation voltage input/output | 2 kV DC (routine test) |
Switching frequency | 190.00 kHz ... 220.00 kHz (Auxiliary converter stage) |
Switching frequency | 67.00 kHz ... 135.00 kHz (Main converter stage) |
Product properties
Product family | QUINT POWER |
MTBF (IEC 61709, SN 29500) | > 1369000 h (25 °C) |
MTBF (IEC 61709, SN 29500) | > 793000 h (40 °C) |
MTBF (IEC 61709, SN 29500) | > 328000 h (60 °C) |
Insulation characteristics
Protection class | Special with SELV input and output |
Degree of pollution | 2 |
Life expectancy (electrolytic capacitors)
Current | 2.5 A |
Temperature | 40 °C |
Time | 359600 h |
Additional text | 24 V DC |
Current | 5 A |
Temperature | 40 °C |
Time | 176200 h |
Additional text | 24 V DC |
Current | 5 A |
Temperature | 30 °C |
Time | 352500 h |
Additional text | 24 V DC |
Item dimensions
Width | 50 mm |
Height | 130 mm |
Depth | 125 mm |
Item dimensions with alternative mounting
Width | 122 mm |
Height | 130 mm |
Depth | 53 mm |
Installation dimensions
Installation distance right/left (active) | 15 mm / 15 mm (≤ 70 °C) |
Installation distance right/left (passive) | 0 mm / 0 mm (≤ 70 °C) |
Installation distance top/bottom (active) | 50 mm / 50 mm (≤ 70 °C) |
Installation distance top/bottom (passive) | 50 mm / 50 mm (≤ 70 °C) |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
With protective coating | No |
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
Housing Material | Metal |
Hood version | Stainless steel X6Cr17 |
Side element version | Aluminum |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Ambient temperature (start-up type tested) | -40 °C |
Maximum altitude | ≤ 5000 m (> 2000 m, observe derating) |
Climatic class | 3K22 (in accordance with EN 60721-3-3) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (Operation) | 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C) |
Overvoltage category
EN 61010-1 | II (≤ 5000 m) |
EN 62477-1 | III (≤ 2000 m) |
Safety for measurement, control, and laboratory equipment
Standard designation | Electrical safety (of control and regulation devices) |
Standards/specifications | IEC 61010-1 |
Protective extra-low voltage
Standard designation | Protective extra-low voltage |
Standards/specifications | EN 61010-1 (SELV) |
Standards/specifications | IEC 61010-2-201 (PELV) |
Mains voltage dips
Standard designation | Mains variation/undervoltage |
Standards/specifications | EN 61000-4-29 |
Railway applications
Standard designation | Railway applications |
Standards/specifications | EN 50121-3-2 |
Standards/specifications | IEC 62236-3-2 |
Standards/specifications | EN 50121-5 |
Standards/specifications | IEC 62236-5 |
UL
Identification | UL Listed UL 61010-1 |
Identification | UL Listed UL 61010-2-201 |
Identification | UL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) |
CSA
Identification | CAN/CSA-C22.2 No. 61010-1-12 |
Identification | CAN/CSA C22.2 No. 61010-2-201:18 |
SIQ
Identification | Type tested (type approved) |
Identification | CB scheme (IEC 61010-1, IEC 61010-2-201) |
Shipbuilding
Identification | DNV |
Identification | BV |
Identification | NK |
Identification | LR |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
EMC requirements, power plant | IEC 61850-3 |
EMC requirements, power plant | EN 61000-6-5 |
Conducted noise emission | EN 55016 |
Conducted noise emission | EN 61000-6-3 (Class B) |
Noise emission | Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) |
Noise emission | EN 55016 |
Noise emission | EN 61000-6-3 (Class B) |
DNV GL conducted interference | Class B |
Additional text | Bridge and deck area |
DNV GL noise radiation | Class B |
Additional text | Bridge and deck area |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | 8 kV (Test Level 4) |
Discharge in air | 15 kV (Test Level 4) |
Comments | Criterion A |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 1 GHz |
Test field strength | 20 V/m (Test Level 3) |
Frequency Range | 1 GHz ... 6 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) |
Comments | Criterion A |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 1 kV (Test Level 3 - symmetrical) |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 1 kV (Test Level 3 - symmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 3 - asymmetrical) |
Comments | Criterion A |
Conducted interference
Standards/regulations | EN 61000-4-6 |
I/O/S | asymmetrical |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Power frequency magnetic field
Standards/regulations | EN 61000-4-8 |
Frequency | 16.7 Hz |
Frequency | 50 Hz |
Frequency | 60 Hz |
Test field strength | 100 A/m |
Additional text | 60 s |
Comments | Criterion A |
Frequency | 50 Hz |
Frequency | 60 Hz |
Frequency Range | 50 Hz ... 60 Hz |
Test field strength | 1 kA/m |
Additional text | 3 s |
Comments | Criterion A |
Frequency | 0 Hz |
Test field strength | 300 A/m |
Additional text | DC, 60 s |
Comments | Criterion A |
Voltage dips
Standards/regulations | EN 61000-4-29 |
Voltage | 24 V DC |
Voltage dip | 70 % |
Time | 100 ms |
Additional text | Test Level 2 |
Comments | Criterion A |
Voltage dip | 40 % |
Time | 100 ms |
Additional text | Test Level 2 |
Comments | Criterion B |
Voltage dip | 0 % |
Time | 50 ms |
Additional text | Test Level 2 |
Comments | Criterion B |
Pulse-shape magnetic field
Standards/regulations | EN 61000-4-9 |
Test field strength | 1000 A/m |
Comments | Criterion A |
Asymmetrical conducted disturbance variables
Standards/regulations | EN 61000-4-16 |
Test level 1 | 15 Hz 150 Hz (Test Level 3) |
Voltage | 10 V 1 V |
Test level 2 | 150 Hz 1.5 kHz (Test Level 3) |
Voltage | 1 V |
Test level 3 | 1.5 kHz 15 kHz (Test Level 3) |
Voltage | 1 V 10 V |
Test level 4 | 15 kHz 150 kHz (Test Level 3) |
Voltage | 10 V |
Test level 5 | 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) |
Voltage | 10 V (Permanent) |
Test level 6 | 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3) |
Voltage | 100 V (1 s) |
Comments | Criterion A |
Alternating component of direct voltage
Standards/regulations | EN 61000-4-17 |
Alternating component | 15 % (UN) |
Frequency | 50 Hz |
Frequency | 100 Hz |
Frequency | 150 Hz |
Comments | Criterion A |
Alternating component | 14 % (UN) |
Frequency | 300 Hz |
Comments | Criterion A |
Attenuated oscillating wave
Standards/regulations | EN 61000-4-18 |
Input, output (test level 1) | 100 kHz 1 MHz (Test Level 2 - symmetrical) |
Voltage | 0.5 kV |
Input, output (test level 2) | 100 kHz 1 MHz (Test Level 2 - asymmetrical) |
Voltage | 1 kV |
Input, output (test level 3) | 10 MHz (Test Level 2 - asymmetrical) |
Voltage | 0.5 kV |
Signals (test level 1) | 100 kHz 1 MHz (Test Level 2 - symmetrical) |
Voltage | 0.5 kV |
Signals (test level 2) | 100 kHz 1 MHz (Test Level 2 - asymmetrical) |
Voltage | 1 kV |
Comments | Criterion A |
Attenuated oscillating magnetic field
Standards/regulations | EN 61000-4-10 |
Test field strength | 100 A/m |
Test level 1 | 100 kHz |
Test field strength | 100 A/m |
Test level 2 | 1 MHz |
Comments | Criterion A |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
Accessories
Why Proax for Phoenix Contact 2910123?
Proax is an authorized distributor of Phoenix Contact 2910123 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended