Official Distributor
SKU
MPN
NBC-MSD/ 2,0-937 SCO RAIL
Weight
0.144 kg
Series NBC-MSD
NBC-MSD/ 2,0-937 SCO RAIL - Network cable
Network cable, PROFINET CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, PE-X halogen-free, black RAL 9005, shielded (Plastic-coated aluminum foil, tinned copper braided shield), Plug straight M12 SPEEDCON, coding: D / IP65, on free cable end, cable length: 2 m, For railway applications
- Easy and safe: 100 % electrically tested plug-in components
- Securely locked by special vibration brake
- Resistant to temperature influences – tested for an extended temperature range and for resistance to temperature shocks
- Reliable signal transmission – 360° shielding in environments with electromagnetic interference
Technical Specifications
Notes
General | Further products with variable cable type and variable cable length can be found in the accessories section |
Product properties
Application | Railway applications |
Sensor Type | PROFINET |
Number of Positions | 4 |
No. of cable outlets | 1 |
Shielded | yes |
Coding | D |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 3 |
Interfaces
Bus system | PROFINET |
Bus system | Ethernet |
Signal type/category | PROFINET CAT5 (IEC 11801), 100 Mbps |
Signal type/category | Ethernet CAT5 (IEC 11801), 100 Mbps |
Signaling
Status display | No |
Status display present | No |
Electrical properties
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 4 A |
Transmission medium | Copper |
Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
Material specifications
Flammability rating according to UL 94 | V0 |
Connection 1
Type | Plug straight M12 SPEEDCON / IP65 |
Number of Positions | 4 |
Locking Type | SPEEDCON |
Coding type | D (Data) |
Shielded | yes |
Handle color | black |
Material | CuSn (Contact) |
Material | Ni/Au (Contact surface) |
Material | PA 6.6 (Contact carriers) |
Material | PA 6.6 (Grip) |
Material | Zinc die-cast, nickel-plated (Screw connection) |
Standards/regulations | PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
Insertion/withdrawal cycles | ≥ 100 |
Insulation resistance | ≥ 100 MΩ |
Tightening torque | 0.4 Nm |
Degree of Protection | IP65 |
Ambient Temperature (Operation) | -40 °C ... 85 °C |
Connection 2
Type | free cable end |
Cable/line
Cable Length | 2 m |
PROFINET RADOX® railway application CAT5 [937]
Cable weight | 70 kg/km |
Number of Positions | 4 |
Shielded | yes |
Cable Type | PROFINET RADOX® railway application CAT5 [937] |
Conductor structure | 1x4xAWG22/7, SF/TQ |
Signal speed | 75 c |
Conductor structure signal line | 7x 0.25 mm |
AWG Signal Line | 22 |
Conductor Cross Section | 4x 0.34 mm² |
Wire diameter incl. insulation | approx. 1.5 mm |
External Cable Diameter | 6.60 mm ±0.4 mm |
Outer sheath, material | PE-X |
External sheath, color | black RAL 9005 |
Conductor material | silver-plated Cu litz wires |
Material wire insulation | Foamed PE |
Single wire, color | white-blue, orange-yellow |
Thickness, outer sheath | approx. 1.00 mm |
Overall twist | Star quad |
Max. conductor resistance | ≤ 54.4 Ω/km |
Coupling resistance | 200.00 mΩ/m (f ≤ 30 MHz) |
Wave impedance | 100 Ω ±5 Ω (f = 100 MHz) |
Working capacitance | ≤ 65 pF (Line-line) |
Working capacitance | ≤ 100 pF (Line-shield) |
Nominal voltage, cable | 300 V AC |
Test voltage | 2000 V AC (50 Hz, 5 minutes) |
Minimum bending radius, fixed installation | 6 x D |
Smallest bending radius, fixed installation | 40 mm |
Near end crosstalk attenuation (NEXT) | 73 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 70 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 65 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 57 dB (at 31.5 МHz) |
Near end crosstalk attenuation (NEXT) | 52 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 48 dB (at 100 MHz) |
Return attenuation (RL) | 25 dB (at 4 МHz) |
Return attenuation (RL) | 30 dB (at 10 MHz) |
Return attenuation (RL) | 30 dB (at 31.5 МHz) |
Return attenuation (RL) | 30 dB (at 62.5 МHz) |
Return attenuation (RL) | 28 dB (at 100 MHz) |
Remote crosstalk attenuation (FEXT) | 78 dB (with 1 MHz) |
Remote crosstalk attenuation (FEXT) | 77 dB (at 4 МHz) |
Remote crosstalk attenuation (FEXT) | 70 dB (at 10 MHz) |
Remote crosstalk attenuation (FEXT) | 65 dB (at 31.5 МHz) |
Remote crosstalk attenuation (FEXT) | 56 dB (at 62.5 МHz) |
Remote crosstalk attenuation (FEXT) | 48 dB (at 100 MHz) |
Shield attenuation | 2 dB (with 1 MHz) |
Shield attenuation | 4.4 dB (at 4 МHz) |
Shield attenuation | 7.4 dB (at 10 MHz) |
Shield attenuation | 14 dB (at 31.5 МHz) |
Shield attenuation | 20 dB (at 62.5 МHz) |
Shield attenuation | 26 dB (at 100 MHz) |
Shield attenuation | 40.00 dB (30 MHz ≤ f ≤ 100 MHz) |
Halogen-free | in accordance with EN 50267-2-1 |
Flame resistance | EN 60332-1-2 |
Flame resistance | EN 50266 |
Flame resistance | EN 60332-3-25 |
Flame resistance | NF C32-070, 2.1 |
Flame resistance | NF C32-070, 2.2 |
Flame resistance | UL 1685, 12 (FT4) |
Flame resistance | in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) |
Fume corrosiveness | EN 50267-2-2 |
Fume toxicity | BS 6853 B.1 |
Fume toxicity | EN 50305, 9.2 |
Concentration of fumes | BS 6853 D.8.7 |
Concentration of fumes | EN 61034-2 |
Concentration of fumes | UL 1685, 12 (FT4) |
Resistance to Oil | according to IRM 902, 72 h at 100 °C |
Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
Fire protection in rail vehicles | GM/RT 2130 (Category Ia, Ib, II) |
Fire protection in rail vehicles | EN 45545 (Risk level HL1 - HL3) |
Fire protection in rail vehicles | DIN 5510 (Fire protection level 1, 2, 3, 4) |
Fire protection in rail vehicles | NF F16-101 (Category A1, A2, B) |
Fire protection in rail vehicles | NF F16-101 (Class C/F0) |
Fire protection in rail vehicles | NFPA 130 |
Fire protection in rail vehicles | UNI CEI 11170 (Risk level LR1 - LR4) |
Other resistance | Resistance to fuels (according to IRM 903, 168 h at 70 °C) |
Ambient Temperature (Operation) | -50 °C ... 90 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -40 °C ... 90 °C (Cable, flexible installation) |
Ambient temperature (installation) | -25 °C ... 90 °C |
Ambient conditions
Degree of Protection | IP65 |
M12
Standard designation | M12 connector |
Standards/specifications | IEC 61076-2-101 |
Standard designation | Shock, vibration |
Standards/specifications | EN 50155 |
Accessories
Why Proax for Phoenix Contact 1407339?
Proax is an authorized distributor of Phoenix Contact 1407339 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 1407342 - Network cable, PROFINET CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, PE-X halogen-free, black RAL 9005, shielded (Plastic-coated aluminum foil, tinned copper braided shield), Plug straight M12 SPEEDCON, coding: D / IP65, on Plug straight M12 SPEEDCON, coding: D / IP65, cable length: 2 m, For railway applications
- 1422329 - Network cable, PROFINET CAT5 (100 Mbps), 4-position, PE-X halogen-free, black, shielded (Aluminum-lined polyester foil, tinned copper braided shield), Plug straight M12 SPEEDCON, coding: D / IP65, on Plug straight M12 SPEEDCON, coding: D / IP65, cable length: 3.3 m, Product tested according to customer specification/rail application