NBC-MSD/ 3,3-939/MSD SCO SI - Network cable

Network cable, PROFINET CAT5 (100 Mbps), 4-position, PE-X halogen-free, black, shielded (Aluminum-lined polyester foil, tinned copper braided shield), Plug straight M12 SPEEDCON, coding: D / IP65, on Plug straight M12 SPEEDCON, coding: D / IP65, cable length: 3.3 m, Product tested according to customer specification/rail application

Technical Specifications

Notes

GeneralThe cable is 100% electrically tested for continuity.

Product properties

Sensor TypePROFINET
Number of Positions4
No. of cable outlets1
Shieldedyes
CodingD

Insulation characteristics

Overvoltage categoryII
Degree of pollution3

Interfaces

Bus systemPROFINET
Signal type/categoryPROFINET CAT5 (IEC 11801), 100 Mbps

Signaling

Status displayNo
Status display presentNo

Electrical properties

Nominal voltage UN48 V AC
Nominal voltage UN60 V DC
Nominal current IN4 A
Transmission mediumCopper
Transmission characteristics (category)CAT5 (IEC 11801:2002)

Material specifications

Flammability rating according to UL 94V0

Connection 1

TypePlug straight M12 SPEEDCON / IP65
Number of Positions4
Locking TypeSPEEDCON
Coding typeD (Data)
Shieldedyes
Handle colorblack
MaterialCuSn (Contact)
MaterialNi/Au (Contact surface)
MaterialPA (Contact carriers)
MaterialTPU, hardly inflammable, self-extinguishing (Grip)
MaterialZinc die-cast, nickel-plated (Screw connection)
Insertion/withdrawal cycles≥ 100 (Quantity: 500 with Phoenix Contact mating connector)
Insulation resistance≥ 100 MΩ
Tightening torque0.4 Nm
Degree of ProtectionIP65
Ambient Temperature (Operation)-40 °C ... 90 °C

Connection 2

TypePlug straight M12 SPEEDCON / IP65
Number of Positions4
Locking TypeSPEEDCON
Coding typeD (Data)
Shieldedyes
Handle colorblack
MaterialCuSn (Contact)
MaterialNi/Au (Contact surface)
MaterialPA (Contact carriers)
MaterialTPU, hardly inflammable, self-extinguishing (Grip)
MaterialZinc die-cast, nickel-plated (Screw connection)
Insertion/withdrawal cycles≥ 100 (Quantity: 500 with Phoenix Contact mating connector)
Insulation resistance≥ 100 MΩ
Tightening torque0.4 Nm
Degree of ProtectionIP65
Ambient Temperature (Operation)-40 °C ... 90 °C

Cable/line

Cable Length3.3 m

PROFINET BETAtrans® railway application CAT5 [939]

Cable weight71 kg/km
Number of Positions4
Shieldedyes
Cable TypePROFINET BETAtrans® railway application CAT5 [939]
Conductor structure1x4xAWG22/7, SF/TQ
Signal runtime4.4 ns/m
Signal speed0.75 c
Conductor structure signal line7x 0.25 mm
AWG Signal Line22
Conductor Cross Section4x 0.34 mm²
Wire diameter incl. insulation1.4 mm ±0.1 mm
External Cable Diameter6.60 mm ±0.2 mm
Outer sheath, materialPE-X
External sheath, colorblack
Conductor materialTin-plated Cu litz wires
Material wire insulationCell PE
Single wire, colorwhite-blue, orange-yellow
Thickness, outer sheath1.00 mm
Overall twistStar quad
Max. conductor resistance≤ 54.4 Ω/km
Insulation resistance≥ 5 GΩ*km
Coupling resistance< 13.00 mΩ/m (f = 1 MHz)
Coupling resistance< 8.00 mΩ/m (f = 10 MHz ... 100 MHz)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Cable capacity44 nF/km (Line-line)
Cable impedance100 Ω ±15 Ω (f = 0.5 MHz ... 3 MHz)
Nominal voltage, cable125 V
Test voltage Core/Core1000 V AC (50 Hz, 1 min.)
Test voltage Core/Shield1000.00 V AC (50 Hz, 1 min.)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation6 x D
Smallest bending radius, fixed installation33 mm
Smallest bending radius, movable installation40 mm
Tensile strength≤ 60 N (temporary)
Tensile strength≤ 15 N (Permanent)
Near end crosstalk attenuation (NEXT)76 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)71 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)64 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)60 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)56 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)52 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)48 dB (at 100 MHz)
Near end crosstalk attenuation (NEXT)45 dB (at 155 MHz)
Near end crosstalk attenuation (NEXT)42 dB (at 200 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)73 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)68 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)61 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)57 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)53 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)49 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)45 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)42 dB (at 155 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)39 dB (at 200 MHz)
Return attenuation (RL)25 dB (with 1 MHz)
Return attenuation (RL)25 dB (at 4 МHz)
Return attenuation (RL)28 dB (at 10 MHz)
Return attenuation (RL)28 dB (at 16 MHz)
Return attenuation (RL)27 dB (at 31.25 МHz)
Return attenuation (RL)26 dB (at 62.5 МHz)
Return attenuation (RL)25 dB (at 100 MHz)
Return attenuation (RL)25 dB (at 155 MHz)
Return attenuation (RL)23 dB (at 200 MHz)
Shield attenuation1.5 dB (with 1 MHz)
Shield attenuation3.3 dB (at 4 МHz)
Shield attenuation5.3 dB (at 10 MHz)
Shield attenuation6.9 dB (at 16 MHz)
Shield attenuation9.9 dB (at 31.25 МHz)
Shield attenuation14.5 dB (at 62.5 МHz)
Shield attenuation18.8 dB (at 100 MHz)
Shield attenuation23.6 dB (at 155 MHz)
Shield attenuation27.3 dB (at 200 MHz)
Shield attenuation60.00 dB (up to 1000 MHz)
Halogen-freein accordance with EN 50267-2-1
Halogen-freein accordance with EN 60684-2
Flame resistancein accordance with EN 60332-1-2
Flame resistancein accordance with EN 50266-2-5
Flame resistancein accordance with ISO 14572 5.21 (UN ECE-R 118.01)
Concentration of fumesEN 61034-2
Resistance to Oilin accordance with EN 50306-4, 72 hours at 100°C, IRM 902
Fire protection in rail vehiclesBS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
Fire protection in rail vehiclesDIN 5510-2 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehiclesEN 45545-2 (Risk level HL1 - HL3)
Fire protection in rail vehiclesEN 50306-4
Fire protection in rail vehiclesNF F16-101 (Classification C/F1)
Fire protection in rail vehiclesNF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
Fire protection in rail vehiclesNFPA 130
Fire protection in rail vehiclesPN-K-02511
Fire protection in rail vehiclesUIC 564-2 (Class A)
Other resistanceResistant to fuel (in accordance with EN 50306-4, 168 hours at 70°C, IRM 903)
Other resistanceResistant to ozone (in accordance with EN 50306-4, 72 hours at 40°C, method B, volumetric concentration of 200 x 10-6)
Ambient Temperature (Operation)-40 °C ... 85 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 70 °C (Cable, flexible installation)
Ambient Temperature (Operation)160 °C (Short circuit)

Standards and Regulations

Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Why Proax for Phoenix Contact 1422329?

Proax is an authorized distributor of Phoenix Contact 1422329 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability