2905137
SKU
PHX2905137
MPN
PLC-V8C/PT-24DC/EM
Weight
0.13 kg
Series PLC-V
PLC-V8C/PT-24DC/EM - Extension module
PLC logic extension module with 16 I/Os, for plug-in connection to eight PLC-INTERFACE terminal blocks for extending the basic module (a maximum of two extension modules can be connected to a basic module), Push-in connection
Technical Specifications
Notes
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
| Product family | PLC logic |
| Operating mode | 100% operating factor |
Insulation characteristics
| Insulation | Basic insulation |
Insulation characteristics: Air clearances and creepage distances
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 2 |
Air clearances and creepage distances
| Rated Insulation Voltage | 50 V |
| Rated surge voltage | 0.8 kV |
Supply
| Supply Voltage | 24 V DC |
| Supply Voltage Range | 19.2 V DC ... 26.4 V DC |
| Maximum input current at UN | 65 mA |
| Protective circuit | Reverse polarity protection |
| Protective circuit | Surge protection |
Digital inputs
| Number of Inputs | 8 (2 configurable as analog) |
| Description of the input | EN 61131-2, type 3 |
| Input Voltage | 24 V DC |
| Signal level "0" signal | < 5 V |
| Signal level "1" signal | > 11 V |
| Input current "0" signal | < 1 mA |
| Input current "1" signal | typ. 2.5 mA |
| Status display | Yellow LED |
Analog inputs
| Number of Inputs | 2 (IN6 and IN7 are configurable as analog) |
| Input voltage range | 0 V ... 10 V |
| Input resistance | > 3.5 kΩ |
Contact to PLC-INTERFACE
| Number of Inputs | ≤ 8 |
| Description of the input | technical data depends on the PLC-INTERFACE terminal block used |
| Input Voltage | 19 V DC |
| Typical current consumption | 4 mA |
| Input resistance | < 100 mΩ |
Output data
| Number of Outputs | ≤ 8 |
| Nominal Output Voltage | 24 V DC |
| Nominal Current | 9 mA |
COMBICON connection
| Connection Method | Push-in connection |
| Stripping length | 9 mm |
| Number of Connections | 1 |
| Number of Positions | 10 |
| Note | Device supply and 8 x inputs |
| Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.25 mm² ... 0.5 mm² (Ferrule with plastic sleeve) |
| Conductor cross section flexible | 0.25 mm² ... 1.5 mm² (Ferrules without plastic sleeve) |
| Conductor cross section AWG | 26 ... 16 |
PLC logic - bus
| Connection Method | Insulation displacement connection |
| Number of Connections | 1 |
| Number of Positions | 4 |
Signaling
| Status display | Green LED |
Dimensions
| Width | 50 mm |
| Height | 48.5 mm |
| Height | 111 mm (with relay) |
| Depth | 82.5 mm |
| Depth | 87 mm (with relay) |
Material specifications
| Color | gray (RAL 7042) |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -20 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 95 % |
CE
| Certificate | CE-compliant |
UL, USA/Canada
| Identification | Class I, Div. 2, Groups A, B, C, D T4 |
UL, Canada
| Identification | Class I, Zone 2, Ex ec IIC Gc T4 X |
UL, USA
| Identification | Class I, Zone 2, AEx ec IIC T4 |
Air clearances and creepage distances
| Standards/regulations | EN IEC 60664-1 |
Mounting
| Mounting Type | Plug-in mounting |
| Assembly instructions | can be plugged onto 8 x PLC-INTERFACE terminal blocks |
| Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2905137?
Proax is an authorized distributor of Phoenix Contact 2905137 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
PLC-V8L/FLK14/OUT - V8 adapter for 8 x PLC-INTERFACE (14 mm), controller: PLC system cabling of output cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: plusschaltend
V8 adapter for 8 x PLC-INTERFACE (14 mm), controller: PLC system cabling of output cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: minusschaltend
PLC-V8/FLK14/IN/M - V8 adapter for 8 x PLC-INTERFACE (6.2 mm), controller: PLC system cabling of input cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: minusschaltend
PLC-V8/FLK14/IN - V8 adapter for 8 x PLC-INTERFACE (6.2 mm), controller: PLC system cabling of input cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: plusschaltend
PLC-V8/FLK14/OUT - V8 adapter for 8 x PLC-INTERFACE (6.2 mm), controller: PLC system cabling of output cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: plusschaltend
PLC-V8/FLK14/OUT/M - V8 adapter for 8 x PLC-INTERFACE (6.2 mm), controller: PLC system cabling of output cards, connection 1: IDC/FLK pin strip 1x 14-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: minusschaltend
PLC-V8/D15B/IN - V8 adapter for 8 x PLC-INTERFACE (6.2 mm), controller: PLC system cabling of input cards, connection 1: D-SUB socket strip 1x 15-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: plusschaltend
PLC-V8/D15B/OUT - V8 adapter for 8 x PLC-INTERFACE (6.2 mm), controller: PLC system cabling of output cards, connection 1: D-SUB socket strip 1x 15-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: plusschaltend
PLC-V8/D15S/IN - V8 adapter for 8 x PLC-INTERFACE (6.2 mm), controller: PLC system cabling of input cards, connection 1: D-SUB pin strip 1x 15-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: plusschaltend
PLC-V8/D15S/OUT - V8 adapter for 8 x PLC-INTERFACE (6.2 mm), controller: PLC system cabling of output cards, connection 1: D-SUB pin strip 1x 15-position, connection 2: Plug-in connection (Can be snapped onto 8x PLC-INTERFACE terminals), connection 3: Screw connection 1x 2-position, number of channels: 8, control logic: plusschaltend