Series PLC-RSC

PLC-RSC-120UC/ 1AU/SEN - Relay Module

PLC-INTERFACE for input functions, consisting of PLC-BSC.../SEN basic terminal block with screw connection and plug-in miniature relay with multi-layer gold contact, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input voltage 120 V AC/110 V DC

  • Time savings of up to 60 %
  • No need for additional modular terminal blocks
  • Efficient connection to system cabling using V8 adapter
  • Relay modules with safe isolation according to DIN EN 50178 between coil and contact
  • Space savings of up to 80 %
  • Sensor connected directly to relay module
  • Functional plug-in bridges
Technical Specifications

Product properties

Product familyPLC-INTERFACE
ApplicationInput function
Operating mode100% operating factor
Mechanical service life2x 107 cycles

Electrical properties

Maximum power dissipation for nominal condition0.42 W
Test voltage (Winding/contact)4 kV AC (50 Hz, 1 min., winding/contact)

Insulation characteristics: Coil/contact

Rated Insulation Voltage250 V
Rated impulse withstand voltage6 kV
Overvoltage categoryIII
Degree of pollution3

Coil side

Nominal input voltage UN120 V AC
Nominal input voltage UN110 V DC
Input voltage range93.6 V AC/DC ... 168 V AC/DC (20 °C)
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN3.5 mA
Typical response time6 ms
Typical release time15 ms
Protective circuitBridge rectifier; Bridge rectifier
Operating voltage displayYellow LED

Switching

Contact switching type1 N/O contact
Type of switch contactSingle contact
Contact MaterialAgSnO, hard gold-plated
Maximum Switching Voltage30 V AC
Maximum Switching Voltage36 V DC
Minimum Switching Voltage100 mV (at 10 mA)
Limiting Continuous Current50 mA
Maximum Inrush Current50 mA
Min. switching current1 mA (24 V)
Short-circuit current200 A (conditional short-circuit current)
Interrupting rating (ohmic load) max.1.2 W (at 24 V DC)
Output fuse4 A gL/gG NEOZED

Switching: when the gold layer is destroyed

Notethe following values are applicable if a gold layer is destroyed
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage5 V (at 100 mA)
Limiting Continuous Current6 A
Min. switching current10 mA (at 12 V)
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Interrupting rating (ohmic load) max.20 W (at 48 V DC)
Interrupting rating (ohmic load) max.18 W (at 60 V DC)
Interrupting rating (ohmic load) max.23 W (at 110 V DC)
Interrupting rating (ohmic load) max.40 W (at 220 V DC)
Interrupting rating (ohmic load) max.1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.1 A (at 220 V, DC13)
Switching capacity3 A (at 24 V, AC15)
Switching capacity3 A (at 120 V, AC15)
Switching capacity3 A (at 230 V, AC15)

Connection data

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14
Tightening torque0.6 Nm ... 0.8 Nm

Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of protection (Relay base)IP20 (Relay base)
Ambient Temperature (Operation)-40 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Standards/regulations

Standards/regulationsIEC 60664
Standards/regulationsIEC 60947-5-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2966320?

Proax is an authorized distributor of Phoenix Contact 2966320 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size10
Recommended
Sold in quantities of 10

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability