Series PLC-RSC

PLC-RSC-120UC/21HC - Relay Module

PLC-INTERFACE, consisting of PLC-BSC.../21 HC basic terminal block with screw connection and plug-in miniature relay for high continuous current, for mounting on DIN rail NS 35/7,5, limiting continuous current up to 10 A, 1 changeover contact, input voltage 120 V AC/110 V DC

  • All common input voltages of 12 V DC ... 230 V AC
  • Efficient connection to system cabling using V8 adapter
  • Long electrical service life thanks to 16 A relay
  • Safe isolation between coil and contact side
  • Max. continuous current of 10 A
  • Functional plug-in bridges
Technical Specifications

Product properties

Product familyPLC-INTERFACE
ApplicationHigh continuous currents
Operating mode100% operating factor
Mechanical service life3x 107 cycles

Insulation characteristics

InsulationSafe isolation, reinforced insulation
InsulationSafe isolation, reinforced insulation
Overvoltage categoryIII
Pollution degree3

Electrical properties

Maximum power dissipation for nominal condition0.54 W
Test voltage (Winding/contact)4 kV AC (50 Hz, 1 min., winding/contact)
Rated surge voltage6 kV

Coil side

Nominal input voltage UN120 V AC
Nominal input voltage UN110 V DC
Input voltage range102 V AC ... 168 V AC (20 °C)
Input voltage range85.8 V DC ... 154 V DC (20 °C)
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN4.2 mA (at 110 V DC)
Typical input current at UN4.5 mA (at 120 V AC)
Typical response time7 ms
Typical release time10 ms
Protective circuitBridge rectifier; Bridge rectifier
Operating voltage displayYellow LED

Switching

Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact MaterialAgNi
Maximum Switching Voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum Switching Voltage12 V (10 mA)
Limiting Continuous Current10 A
Limiting Continuous Current6 A (value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Maximum Inrush Current30 A (300 ms)
Min. switching current10 mA (12 V)
Interrupting rating (ohmic load) max.240 W (at 24 V DC)
Interrupting rating (ohmic load) max.58 W (at 48 V DC)
Interrupting rating (ohmic load) max.48 W (at 60 V DC)
Interrupting rating (ohmic load) max.50 W (at 110 V DC)
Interrupting rating (ohmic load) max.80 W (at 220 V DC)
Interrupting rating (ohmic load) max.2500 VA (for 250 V AC)
Interrupting rating (ohmic load) max. bridged144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Interrupting rating (ohmic load) max. bridged1500 VA (for 250 V AC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.2 A (at 250 V, DC13)
Switching capacity6 A (at 24 V, AC15)
Switching capacity6 A (at 120 V, AC15)
Switching capacity6 A (at 250 V, AC15)

Connection data

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14
Tightening torque0.6 Nm ... 0.8 Nm

Dimensions

Width14 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of protection (Relay)RT II (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Ambient Temperature (Operation)-40 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Standards and Regulations

Standards/regulationsIEC 60947-5-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact PLC-RSC-120UC/21HC?

Proax is an authorized distributor of Phoenix Contact PLC-RSC-120UC/21HC and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPLCRSC120UC21HC
Pack Size10
Recommended
Sold in quantities of 10

Available for order