Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
MINI MCR-SL-CVS-24-5-10-NC
Weight
0.087 kg

MINI MCR-SL-CVS-24-5-10-NC - Constant voltage source

Constant voltage source, input voltage 9.6 - 30 V DC, output voltage 10 V, 7.5 V, 5 V, 2.5 V DC, electrically isolated, can be configured via DIP switches, screw connection technology, standard configuration

Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMINI Analog
ConfigurationDIP switches

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Functionality

ConfigurationDIP switches

Electrical properties

Setting range comparison± 300 mV
Maximum power dissipation for nominal condition300 mW
Maximum temperature coefficient< 0.01 %/K
Temperature coefficient, typical< 0.002 %/K
Maximum transmission error≤ 0.1 % (of final value)
Maximum transmission error≤ 0.5 % (Without adjustment)

Electrical isolation Input/output

Rated Insulation Voltage50 V AC/DC
Test voltage1.5 kV AC (50 Hz, 60 s)
InsulationBasic insulation in accordance with IEC/EN 61010

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Max. current consumption< 25 mA (10 V output with 30 mA load at 24 V DC IN)
Max. current consumption< 65 mA (10 V output with 30 mA load at 9.6 V DC IN)
Max. current consumption< 50 mA (10 V voltage output with 30 mA load at 12 V DC IN)
Max. current consumption< 20 mA (10 V voltage output with 30 mA load at 30 V DC IN)
Power consumption< 600 mW (at 24 V IN)
Power consumption< 624 mW (at 9.6 V IN)
Power consumption< 564 mW (At 12 V IN)
Power consumption< 540 mW (at 30 V IN)

Signal: Voltage

Voltage input signal9.6 V DC ... 30 V DC
Configurable/programmableYes, preconfigured
Max. voltage output signal10 V DC
Max. voltage output signal7.5 V DC
Max. voltage output signal5 V DC
Max. voltage output signal2.5 V DC
Short-circuit currentapprox. 32 mA
Output Current≤ 30 mA
Ripple< 20 mVPP

Connection data

Connection MethodScrew connection
Stripping length12 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 12

Dimensions

Width6.2 mm
Height93.1 mm
Depth101.2 mm

Material specifications

Colorgreen (RAL 6021)
Housing MaterialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

UL, USA/Canada

IdentificationUL 508 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T6
IdentificationClass I, Zone 2, Group IIC

Shipbuilding approval

CertificateDNV GL TAA00002R0
TemperatureB
HumidityB
VibrationB
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Electromagnetic compatibilityConformance with EMC directive
Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Noise emissionEN 61000-6-4

Electrostatic discharge

Standards/regulationsEN 61000-4-2
CommentsSafety measures must be taken to prevent electrostatic discharge.

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value3 %
CommentsCriterion A

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value3 %
CommentsCriterion B

Surge current load (surge)

Standards/regulationsEN 61000-4-5
CommentsCriterion B

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value0.5 %
CommentsCriterion A

Mounting

Mounting TypeDIN rail mounting
Assembly noteThe DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2902822?

Proax is an authorized distributor of Phoenix Contact 2902822 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability