MINI MCR-SL-F-UI-NC - Frequency measuring transducer
The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Screw connection, standard configuration.
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
Product family | MINI Analog |
No. of channels | 1 |
Operating elements | Press/slide button |
Configuration | DIP switches |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Functionality
Configuration | DIP switches |
Electrical properties
Electrical isolation | 3-way isolation |
Electrical isolation between input and output | yes |
Protective circuit | Transient protection |
Step response (0–99%) | < 35 ms (At f > 500 Hz) |
Maximum temperature coefficient | 0.01 %/K |
Transmission error in the set measuring range | 0.1 % |
Electrical isolation Input/output/power supply
Rated Insulation Voltage | 50 V AC/DC |
Test voltage | 1.5 kV AC (50 Hz, 60 s) |
Insulation | Basic insulation in accordance with IEC/EN 61010 |
Supply
Supply Voltage Range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
Typical current consumption | < 28 mA (at IOUT = 20 mA, 24 V DC, load 500 Ω) |
Power consumption | < 800 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω) |
Measurement: Frequency
Configurable/programmable | Yes |
Available Input Sources | NPN/PNP transistor outputs |
Available Input Sources | NAMUR initiators |
Available Input Sources | Floating relay contact (dry contact) |
Max. voltage input signal | 30 V (incl. DC voltage) |
Frequency measuring range | 0.002 Hz ... 20 kHz (DIP switch) |
Frequency measuring range | 0.002 Hz ... 80 kHz (Teach-in wheel) |
Signal
Number of Inputs | 1 |
Input Signal | Frequency |
Signal: Voltage/current
Number of Outputs | 1 |
Configurable/programmable | Yes |
Voltage output signal | 0 V ... 5 V |
Voltage output signal | 1 V ... 5 V |
Voltage output signal | 0 V ... 10 V |
Voltage output signal | 10 V ... 0 V |
Max. voltage output signal | 12.3 V |
Current Output Signal | 0 mA ... 20 mA |
Current Output Signal | 4 mA ... 20 mA |
Current Output Signal | 20 mA ... 0 mA |
Current Output Signal | 20 mA ... 4 mA |
Max. current output signal | 24.6 mA |
Load/output load voltage output | ≥ 10 kΩ |
Load/Output Load Current Output | 500 Ω (20 mA) |
Ripple | < 20 mVPP |
Ripple | < 20 mVPP (500 Ω) |
Connection data
Connection Method | Screw connection |
Stripping length | 12 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 26 ... 12 |
Signaling
Status display | LED red |
Dimensions
Width | 6.2 mm |
Height | 93.1 mm |
Depth | 101.2 mm |
Material specifications
Color | green (RAL 6021) |
Housing Material | PBT |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 65 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T4 |
Identification | Class I, Zone 2, Group IIC |
Shipbuilding approval
Certificate | DNV GL TAA00002R0 |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | B |
EMC | A |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 0.1 % |
Fast transients (burst)
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 2 % |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Conducted interference
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 0.3 % |
Standards and Regulations
Electrical isolation | 3-way isolation |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2902832?
Proax is an authorized distributor of Phoenix Contact 2902832 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |