Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PLC-RPT-110UC/21-21/RW
Weight
0.065 kg
This product is Not Cancellable/Not Returnable
Series PLC-RPT

PLC-RPT-110UC/21-21/RW - Relay Module

PLC-INTERFACE for railway applications, consisting of basic terminal block with Push-in connection and plug-in miniature relay with power contact, range: 0.7 x UN to 1.25 x UN, temperature class TX: -40°C to +70°C, 2 changeover contacts, input voltage 110 V DC

  • Optimum relay operation thanks to wide-range electronics
  • Safe isolation between coil and contact side
  • Vibration and shock resistance in accordance with EN 50155
  • Certified in accordance with EN 50155
  • Input voltage range of 0.7 to 1.25 x UN (1.4 x UN briefly)
  • Temperature range: -40 °C ... + 70 °C (short-term 85 °C)
Technical Specifications

Product properties

Product familyPLC-INTERFACE
ApplicationRailway applications
Installation locationAttached to the vehicle body
Operating mode100% operating factor
Mechanical service lifeapprox. 3x 107 cycles

Insulation characteristics

InsulationBasic insulation
InsulationBasic insulation
Overvoltage categoryIII
Pollution degree2

Electrical properties

Maximum power dissipation for nominal condition0.5 W
Test voltage (Winding/contact)5 kVrms (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)2.5 kVrms (50 Hz, 1 min., changeover contact/changeover contact)
Rated Insulation Voltage250 V AC
Rated surge voltage6 kV

Coil side

Nominal input voltage UN110 V DC
Input voltage range77 V DC ... 137.5 V DC
Input voltage range in reference to UN0.7 ... 1.25
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN4.5 mA
Typical response time5 ms
Typical release time11 ms
Coil Voltage60 V DC
Protective circuitBridge rectifier
Protective circuitSurge protection; Freewheeling diode
Protective circuitRCZ filter
Protective circuitWide-range electronics
Operating voltage displayYellow LED

Switching

Contact switching type2 changeover contacts
Type of switch contactSingle contact
Contact MaterialAgNi
Maximum Switching Voltage250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum Switching Voltage5 V (10 mA)
Limiting Continuous Current6 A
Maximum Inrush Current15 A (300 ms)
Min. switching current10 mA (5 V)
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Interrupting rating (ohmic load) max.85 W (at 48 V DC)
Interrupting rating (ohmic load) max.60 W (at 60 V DC)
Interrupting rating (ohmic load) max.44 W (at 110 V DC)
Interrupting rating (ohmic load) max.60 W (at 220 V DC)
Interrupting rating (ohmic load) max.1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 250 V, DC13)
Switching capacity3 A (at 24 V, AC15)
Switching capacity3 A (at 120 V, AC15)
Switching capacity3 A (at 250 V, AC15)

Connection data

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14

Dimensions

Width14 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of protection (Relay)RT III (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Ambient Temperature (Operation)-40 °C ... 70 °C (Temperature class TX)
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Standards and Regulations

Standards/regulationsIEC 60947-5-1
Standards/regulationsEN 50155 (VDE 0115 part 200)
Standards/regulationsEN 61373
Standards/regulationsEN 50121

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2900348?

Proax is an authorized distributor of Phoenix Contact 2900348 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size10
Recommended
Sold in quantities of 10

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability