PLC-RPT-120UC/21HC/MS - Relay Module
PLC-INTERFACE, consisting of a relay base and pluggable power contact relay with manual operation, integrated status LED, Push-in connection, 1 changeover contact, Bridge rectifier, Input voltage: 120 V AC / 110 V DC
Technical Specifications
Product properties
Product family | PLC-INTERFACE |
Application | Palm switch |
Application | High continuous currents |
Operating mode | 100% operating factor |
Mechanical service life | 5x 106 cycles |
Insulation characteristics
Insulation | Safe isolation, reinforced insulation |
Insulation | Safe isolation, reinforced insulation |
Overvoltage category | III |
Pollution degree | 2 |
Electrical properties
Maximum power dissipation for nominal condition | 0.6 W |
Test voltage (Winding/contact) | 4 kVrms (50 Hz, 1 min., winding/contact) |
Rated Insulation Voltage | 250 V AC |
Rated surge voltage | 6 kV |
Coil side
Nominal input voltage UN | 120 V AC |
Nominal input voltage UN | 110 V DC |
Input voltage range | 96 V AC ... 168 V AC (20 °C) |
Input voltage range | 93.5 V DC ... 154 V DC (20 °C) |
Drive and function | monostable |
Drive (polarity) | polarized |
Typical input current at UN | 5 mA |
Typical response time | 6 ms (110 V DC) |
Typical response time | 3 ms ... 15 ms (120 V AC) |
Typical release time | 8 ms (110 V DC) |
Typical release time range | 3 ms ... 15 ms (120 V AC) |
Protective circuit | Bridge rectifier; Bridge rectifier |
Operating voltage display | Yellow LED |
Switching
Contact switching type | 1 changeover contact |
Type of switch contact | Single contact |
Contact Material | AgNi |
Maximum Switching Voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
Minimum Switching Voltage | 12 V (10 mA) |
Limiting Continuous Current | 10 A |
Maximum Inrush Current | 24 A (20 ms) |
Min. switching current | 10 mA (12 V) |
Interrupting rating (ohmic load) max. | 264 W (24 V DC) |
Interrupting rating (ohmic load) max. | 62 W (48 V DC) |
Interrupting rating (ohmic load) max. | 48 W (60 V DC) |
Interrupting rating (ohmic load) max. | 52 W (110 V DC) |
Interrupting rating (ohmic load) max. | 66 W (220 V DC) |
Interrupting rating (ohmic load) max. | 2750 VA (250 V AC) |
Switching capacity | 2 A (24 V, DC13) |
Switching capacity | 3 A (230 V, AC15) |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² ... 1 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 ... 14 |
Dimensions
Width | 14 mm |
Height | 80 mm |
Depth | 104 mm |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Ambient conditions
Degree of protection (Relay) | RT II (Relay) |
Degree of protection (Relay base) | IP20 (Relay base) |
Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient Temperature (Operation) | -40 °C ... 55 °C |
Ambient temperature (storage/transport) | -20 °C ... 85 °C |
Altitude | ≤ 2000 m |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
UL, USA
Identification | UL 508 |
Identification | UL 508 Recognized |
UL, USA/Canada
Identification | UL 508 |
Identification | UL 508 Recognized |
Shipbuilding approval
Certificate | TAE0000196 |
Corrosive gas test
Identification | ISA-S71.04. G3 Harsh Group |
Identification | EN 60068-2-60 |
DNV GL data
Temperature | D |
Humidity | A |
Vibration | B/C |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive |
Electromagnetic compatibility | Conformance with EMC directive |
Standards and Regulations
Standards/regulations | IEC 60947-5-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact PLC-RPT-120UC/21HC/MS?
Proax is an authorized distributor of Phoenix Contact PLC-RPT-120UC/21HC/MS and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | PLCRPT120UC21HCMS |
Pack Size | 10 |
Recommended