Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2909669
Weight
0.037 kg
Series PLC-RPT

PLC-RPT-120UC/21/MS - Relay Module

PLC-INTERFACE, consisting of PLC-BPT.../21 basic terminal block with Push-in connection and plug-in miniature relay with power contact and manual operation, 1 changeover contact, 120 V AC/110 V DC input voltage

  • Slim design
  • Efficient connection to system cabling using V8 adapter
  • RT III sealed relay
  • Safe isolation between coil and contact side
  • Functional plug-in bridges
  • Integrated input circuit and interference suppression circuit
Technical Specifications

Notes

Notes on operationSeparating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500....

Product properties

Product familyPLC-INTERFACE
ApplicationPalm switch
Operating mode100% operating factor
Mechanical service life1x 107 cycles

Electrical properties

Maximum power dissipation for nominal condition0.42 W
Test voltage (Winding/contact)4 kV AC (50 Hz, 1 min., winding/contact)

Insulation characteristics: Coil/contact

Rated Insulation Voltage250 V
Rated impulse withstand voltage6 kV
Overvoltage categoryIII
Degree of pollution3

Coil side

Nominal input voltage UN120 V AC
Nominal input voltage UN110 V DC
Input voltage range93.6 V AC ... 168 V AC (20 °C)
Input voltage range85.8 V DC ... 154 V DC (20 °C)
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN3.5 mA (at UN = 120 V AC)
Typical input current at UN3 mA (at UN = 110 V DC)
Typical response time6 ms
Typical release time15 ms
Protective circuitBridge rectifier; Bridge rectifier
Operating voltage displayYellow LED

Switching

Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact MaterialAgSnO
Maximum Switching Voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum Switching Voltage5 V (at 100 mA)
Limiting Continuous Current6 A
Maximum Inrush Current10 A (4 s)
Min. switching current10 mA (12 V)
Short-circuit current200 A (conditional short-circuit current)
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Interrupting rating (ohmic load) max.20 W (at 48 V DC)
Interrupting rating (ohmic load) max.18 W (at 60 V DC)
Interrupting rating (ohmic load) max.23 W (at 110 V DC)
Interrupting rating (ohmic load) max.40 W (at 220 V DC)
Interrupting rating (ohmic load) max.1500 VA (for 250 V AC)
Output fuse4 A gL/gG NEOZED
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.1 A (at 220 V, DC13)
Switching capacity3 A (at 24 V, AC15)
Switching capacity3 A (at 120 V, AC15)
Switching capacity3 A (at 230 V, AC15)

Connection data

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14

Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of protection (Relay)RT II (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Ambient Temperature (Operation)-40 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Standards/regulations

Standards/regulationsIEC 60664
Standards/regulationsIEC 60664A
Standards/regulationsDIN VDE 0110
Standards/regulationsIEC 60255/DIN VDE 0435 (in relevant parts)

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact PLC-RPT-120UC/21/MS?

Proax is an authorized distributor of Phoenix Contact PLC-RPT-120UC/21/MS and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPLCRPT120UC21MS
Pack Size10
Recommended
Sold in quantities of 10

Available for order

Phoenix Contact Availability