Official Distributor
SKU
MPN
PLC-RPT-120UC/21/SO46
Weight
0.032 kg
Series PLC-RPT
PLC-RPT-120UC/21/SO46 - Relay Module
PLC-INTERFACE for protection against interference currents/voltages on the control side. Consisting of PLC-BPT-120UC/21/SO46 basic terminal block with Push-in connection and plug-in miniature relay with power contact up to 6 A, 1 changeover contact, 120 V AC input voltage
Technical Specifications
Notes
Notes on operation | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500.... |
Notes on operation | The PLC-ATP separating plate should be installed for safe isolation between adjacent modules |
Assembly instruction: | The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. |
Notes on operation | The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
Product properties
Product family | PLC-INTERFACE |
Application | Filter to prevent interference |
Operating mode | 100% operating factor |
Mechanical service life | 2x 107 cycles |
Insulation characteristics
Insulation | Safe isolation, reinforced insulation |
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation | Safe isolation, reinforced insulation |
Overvoltage category | III |
Pollution degree | 3 |
Electrical properties
Maximum power dissipation for nominal condition | 0.84 W |
Test voltage (Winding/contact) | 4 kVrms (50 Hz, 1 min., winding/contact) |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V AC |
Rated surge voltage | 6 kV |
Coil side
Nominal input voltage UN | 120 V AC |
Nominal input voltage UN | 110 V DC |
Input voltage range | 93.6 V AC ... 168 V AC (20 °C) |
Input voltage range | 85.8 V DC ... 154 V DC (20 °C) |
Mains frequency | 50/60 Hz |
Drive and function | monostable |
Drive (polarity) | polarized |
Typical input current at UN | 7 mA (50 Hz) |
Typical input current at UN | 8 mA (60 Hz) |
Typical response time | 7 ms |
Typical release time | 20 ms |
Typical release voltage | 50 V AC |
Coil Voltage | 60 V DC |
Protective circuit | Bridge rectifier |
Protective circuit | RC element |
Status display | Yellow LED |
Switching
Contact switching type | 1 changeover contact |
Type of switch contact | Single contact |
Contact Material | AgSnO, hard gold-plated |
Maximum Switching Voltage | 250 V AC/DC |
Minimum Switching Voltage | 5 V (100 mA) |
Limiting Continuous Current | 6 A |
Maximum Inrush Current | 10 A (4 s) |
Min. switching current | 10 mA (12 V) |
Short-circuit current | 200 A (conditional short-circuit current) |
Interrupting rating (ohmic load) max. | 140 W (24 V DC) |
Interrupting rating (ohmic load) max. | 20 W (48 V DC) |
Interrupting rating (ohmic load) max. | 18 W (60 V DC) |
Interrupting rating (ohmic load) max. | 23 W (110 V DC) |
Interrupting rating (ohmic load) max. | 40 W (220 V DC) |
Interrupting rating (ohmic load) max. | 1500 VA (250 V AC) |
Switching capacity min. | 0.12 W |
Output fuse | 4 A gL/gG NEOZED |
Switching capacity | 2 A (at 24 V, DC13) |
Switching capacity | 0.2 A (at 110 V, DC13) |
Switching capacity | 0.1 A (at 220 V, DC13) |
Switching capacity | 3 A (at 24 V, AC15) |
Switching capacity | 3 A (at 120 V, AC15) |
Switching capacity | 3 A (at 230 V, AC15) |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² ... 1 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 ... 14 |
Dimensions
Width | 6.2 mm |
Height | 80 mm |
Depth | 94 mm |
Material specifications
Color | gray (RAL 7042) |
Ambient conditions
Degree of protection (Relay) | RT III (Relay) |
Degree of protection (Relay base) | IP20 (Relay base) |
Degree of protection (Installation location) | IP54 (Installation location) |
Ambient Temperature (Operation) | -40 °C ... 55 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
Shipbuilding approval
Certificate | TAE0000196 |
Corrosive gas test
Identification | ISA-S71.04. G3 Harsh Group |
Identification | EN 60068-2-60 |
DNV GL data
Temperature | D |
Humidity | A |
Vibration | B/C |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive |
Electromagnetic compatibility | Conformance with EMC directive |
Air clearances and creepage distances between the power circuits
Standards/regulations | IEC 60947-5-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
Why Proax for Phoenix Contact 1125988?
Proax is an authorized distributor of Phoenix Contact 1125988 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended