PLC-RPT-120UC/21/SO46 - Relay Module

PLC-INTERFACE for protection against interference currents/voltages on the control side. Consisting of PLC-BPT-120UC/21/SO46 basic terminal block with Push-in connection and plug-in miniature relay with power contact up to 6 A, 1 changeover contact, 120 V AC input voltage

Technical Specifications

Notes

Notes on operationSeparating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500....
Notes on operationThe PLC-ATP separating plate should be installed for safe isolation between adjacent modules
Assembly instruction:The PLC-ATP separating plate is required at the start and end of every PLC terminal strip.
Notes on operationThe system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.

Product properties

Product familyPLC-INTERFACE
ApplicationFilter to prevent interference
Operating mode100% operating factor
Mechanical service life2x 107 cycles

Insulation characteristics

InsulationSafe isolation, reinforced insulation

Insulation characteristics: Air clearances and creepage distances between the power circuits

InsulationSafe isolation, reinforced insulation
Overvoltage categoryIII
Pollution degree3

Electrical properties

Maximum power dissipation for nominal condition0.84 W
Test voltage (Winding/contact)4 kVrms (50 Hz, 1 min., winding/contact)

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage6 kV

Coil side

Nominal input voltage UN120 V AC
Nominal input voltage UN110 V DC
Input voltage range93.6 V AC ... 168 V AC (20 °C)
Input voltage range85.8 V DC ... 154 V DC (20 °C)
Mains frequency50/60 Hz
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN7 mA (50 Hz)
Typical input current at UN8 mA (60 Hz)
Typical response time7 ms
Typical release time20 ms
Typical release voltage50 V AC
Coil Voltage60 V DC
Protective circuitBridge rectifier
Protective circuitRC element
Status displayYellow LED

Switching

Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact MaterialAgSnO, hard gold-plated
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage5 V (100 mA)
Limiting Continuous Current6 A
Maximum Inrush Current10 A (4 s)
Min. switching current10 mA (12 V)
Short-circuit current200 A (conditional short-circuit current)
Interrupting rating (ohmic load) max.140 W (24 V DC)
Interrupting rating (ohmic load) max.20 W (48 V DC)
Interrupting rating (ohmic load) max.18 W (60 V DC)
Interrupting rating (ohmic load) max.23 W (110 V DC)
Interrupting rating (ohmic load) max.40 W (220 V DC)
Interrupting rating (ohmic load) max.1500 VA (250 V AC)
Switching capacity min.0.12 W
Output fuse4 A gL/gG NEOZED
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.1 A (at 220 V, DC13)
Switching capacity3 A (at 24 V, AC15)
Switching capacity3 A (at 120 V, AC15)
Switching capacity3 A (at 230 V, AC15)

Connection data

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14

Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)

Ambient conditions

Degree of protection (Relay)RT III (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Degree of protection (Installation location)IP54 (Installation location)
Ambient Temperature (Operation)-40 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Air clearances and creepage distances between the power circuits

Standards/regulationsIEC 60947-5-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany

Why Proax for Phoenix Contact PLC-RPT-120UC/21/SO46?

Proax is an authorized distributor of Phoenix Contact PLC-RPT-120UC/21/SO46 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPLCRPT120UC21SO46
Pack Size10
Recommended
Sold in quantities of 10

Available for order