Official Distributor
SKU
MPN
2900323
Weight
0.034 kg
This product is Not Cancellable/Not Returnable
Series PLC-RPT
PLC-RPT-110UC/21AU/RW - Relay Module
PLC-INTERFACE for railway applications, consisting of basic terminal block with Push-in connection and plug-in miniature relay with multi-layer gold contact, range: 0.7 x UN to 1.25 x UN, temperature class TX: -40°C to +70°C, 1 changeover contact, input voltage 110 V DC
- Optimum relay operation thanks to wide-range electronics
- Safe isolation between coil and contact side
- Vibration and shock resistance in accordance with EN 50155
- Certified in accordance with EN 50155
- Input voltage range of 0.7 to 1.25 x UN (1.4 x UN briefly)
- Temperature range: -40 °C ... + 70 °C (short-term 85 °C)
Technical Specifications
Product properties
Product family | PLC-INTERFACE |
Application | Railway applications |
Installation location | Attached to the vehicle body |
Operating mode | 100% operating factor |
Mechanical service life | approx. 2x 107 cycles |
Insulation characteristics
Overvoltage category | III |
Pollution degree | 2 |
Electrical properties
Maximum power dissipation for nominal condition | 0.22 W |
Test voltage (Winding/contact) | 4 kVrms (50 Hz, 1 min., winding/contact) |
Rated Insulation Voltage | 250 V AC |
Rated surge voltage | 6 kV |
Coil side
Nominal input voltage UN | 110 V DC |
Input voltage range | 77 V DC ... 137.5 V DC |
Input voltage range in reference to UN | 0.7 ... 1.25 |
Drive and function | monostable |
Drive (polarity) | polarized |
Typical input current at UN | 2 mA |
Typical response time | 4 ms |
Typical release time | 4 ms |
Coil Voltage | 60 V DC |
Protective circuit | Surge protection; Freewheeling diode |
Protective circuit | RCZ filter |
Protective circuit | Wide-range electronics |
Operating voltage display | Yellow LED |
Switching
Contact switching type | 1 changeover contact |
Type of switch contact | Single contact |
Contact Material | AgSnO, hard gold-plated |
Maximum Switching Voltage | 30 V AC |
Maximum Switching Voltage | 36 V DC |
Minimum Switching Voltage | 100 mV (10 mA) |
Limiting Continuous Current | 50 mA |
Maximum Inrush Current | 50 mA |
Min. switching current | 1 mA (24 V) |
Short-circuit current | 200 A (conditional short-circuit current) |
Interrupting rating (ohmic load) max. | 1.2 W (at 24 V DC) |
Output fuse | 4 A gL/gG NEOZED |
Switching capacity | 1 A (24 V (DC13)) |
Switching capacity | 0.2 A (110 V (DC13)) |
Switching capacity | 0.1 A (220 V (DC13)) |
Switching capacity | 3 A (24 V (AC15)) |
Switching capacity | 3 A (120 V (AC15)) |
Switching capacity | 3 A (230 V (AC 15)) |
Switching: when the gold layer is destroyed
Note | the following values are applicable if a gold layer is destroyed |
Maximum Switching Voltage | 250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.) |
Minimum Switching Voltage | 12 V AC/DC |
Limiting Continuous Current | 6 A (see derating curve) |
Min. switching current | 10 mA |
Interrupting rating (ohmic load) max. | 140 W (at 24 V DC) |
Interrupting rating (ohmic load) max. | 20 W (at 48 V DC) |
Interrupting rating (ohmic load) max. | 18 W (at 60 V DC) |
Interrupting rating (ohmic load) max. | 23 W (at 110 V DC) |
Interrupting rating (ohmic load) max. | 40 W (at 220 V DC) |
Interrupting rating (ohmic load) max. | 1500 VA (for 250 V AC) |
Switching capacity | 2 A (at 24 V, DC13) |
Switching capacity | 0.2 A (at 110 V, DC13) |
Switching capacity | 0.1 A (at 220 V, DC13) |
Switching capacity | 3 A (at 24 V, AC15) |
Switching capacity | 3 A (at 120 V, AC15) |
Switching capacity | 3 A (at 230 V, AC15) |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² ... 1 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 ... 14 |
Dimensions
Width | 6.2 mm |
Height | 80 mm |
Depth | 94 mm |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Ambient conditions
Degree of protection (Relay) | RT III (Relay) |
Degree of protection (Relay base) | IP20 (Relay base) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Temperature class TX) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
Shipbuilding approval
Certificate | TAE0000196 |
Corrosive gas test
Identification | ISA-S71.04. G3 Harsh Group |
Identification | EN 60068-2-60 |
DNV GL data
Temperature | D |
Humidity | A |
Vibration | B/C |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive |
Electromagnetic compatibility | Conformance with EMC directive |
Standards and Regulations
Standards/regulations | IEC 60947-5-1 |
Standards/regulations | EN 50155 (VDE 0115 part 200) |
Standards/regulations | EN 61373 |
Standards/regulations | EN 50121 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact PLC-RPT-110UC/21AU/RW?
Proax is an authorized distributor of Phoenix Contact PLC-RPT-110UC/21AU/RW and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | PLCRPT110UC21AURW |