Series IB-IL-TEMP
IB IL TEMP 4/8 RTD/EF-PAC - Temperature module
Inline, Temperature measurement terminal, Analog RTD inputs: 8 (for resistance temperature detectors), connection technology: 4-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields
- Connection of 8 RTD temperature sensors and linear resistors in 4-conductor technology
- Pt, Ni, Cu, KTY sensor types according to DIN and SAMA
- High precision and noise immunity
- Temperature stability
- High-resolution temperature and resistance measurement
- Resistance values can be preset separately via parameterization bits
- The channels are parameterized independently of one another via the bus system
- Parameterization of wire-break detection sensitivity (firmware 1.10 or later)
- Additional representation in float format according to IEEE754
- Channel scout functionality, for optical channel identification during startup
Technical Specifications
Dimensions
Width | 48.8 mm |
Height | 119.8 mm |
Depth | 71.5 mm |
Note on dimensions | Housing dimensions |
Utilization restriction
CCCex note | Use in potentially explosive areas is not permitted in China. |
Inline local bus
Number of interfaces | 2 |
Connection Method | Inline data jumper |
Transmission Speed | 500 kbps |
Transmission physics | Copper |
Module
ID code (dec.) | 223 |
ID code (hex) | DF |
Length code (hex) | 05 |
Length code (dec) | 05 |
Process data channel | 80 bit |
Input address area | 10 Byte |
Output address area | 10 Byte |
Register length | 96 bit |
Required parameter data | 31 Byte |
Required configuration data | 5 Byte |
Analog
Input name | Analog RTD inputs |
Description of the input | Input for resistive temperature sensors |
Number of Inputs | 8 (for resistance temperature detectors) |
Connection Method | Spring-cage connection |
Connection technology | 4-conductor |
Note regarding the connection technology | shielded |
A/D converter resolution | 24 bit |
Sensor types (RTD) that can be used | Pt, Ni, KTY, Cu sensors, linear resistors |
Data formats | IB IL, S7-compatible |
Measuring Principle | Sigma/Delta process |
Measured value representation | 16 bits (15 bits + sign bit) |
Input filter time | 100 ms |
Input filter time | 120 ms |
Input filter time | 200 ms |
Input filter time | 480 ms (adjustable) |
Differential non-linearity | typ. 1 ppm / ±0.0001 % (in all ranges) |
Integral non-linearity | typ. 30 ppm / ±0.003 % (Pt 100) |
Integral non-linearity | typ. 20 ppm / ±0.002 % (RLin 500 Ω) |
Integral non-linearity | typ. 200 ppm / ±0.02 % (RLin 5000 Ω) |
Linear resistance measuring range | 0 Ω ... 500 Ω |
Linear resistance measuring range | 0 Ω ... 5 kΩ |
Linear resistance measuring range | 0 Ω ... 30 kΩ |
Process data update | 1.8 s (Up to 3.3 s possible depending on operating mode) |
Product properties
Product family | Inline |
Type | modular |
Scope of delivery | including Inline connectors and marking fields |
Operating mode | Process data mode with 5 words/1 word PCP |
Diagnostics messages | Failure of the internal I/O supply I/O error message sent to the bus coupler |
Diagnostics messages | Failure of or insufficient communications power UL I/O error message sent to the bus coupler |
Diagnostics messages | User error Error message in the process data |
Insulation characteristics
Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Electrical properties
Maximum power dissipation for nominal condition | 0.59 W |
Potentials
Power consumption | typ. 0.85 W (entire device) |
Potentials: Communications power (UL)
Supply Voltage | 7.5 V DC (via voltage jumper) |
Current draw | max. 120 mA |
Current draw | typ. 95 mA |
Potentials: Supply of analog modules (UANA)
Supply Voltage | 24 V DC (via voltage jumper) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 15 mA |
Current draw | typ. 6 mA |
Electrical isolation/isolation of the voltage ranges
Test voltage: 7.5 V supply (bus logic), 24 V supply UANA / I/O | 500 V AC, 50 Hz, 1 min. |
Test voltage: 7.5 V supply (bus logic), 24 V supply UANA / functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: I/O/functional ground | 500 V AC, 50 Hz, 1 min. |
Connection technology
Connection name | Inline connector |
Conductor connection
Connection Method | Spring-cage connection |
Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Inline connector
Connection Method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Degree of Protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2897402?
Proax is an authorized distributor of Phoenix Contact 2897402 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended