IB IL TEMP 2 UTH-PAC - Temperature module

Inline, Temperature measurement terminal, Analog UTH inputs: 2 (Thermocouples or linear voltage), connection technology: 2-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field

  • 2 differential inputs for thermocouples or linear voltage
  • 1 input for an external cold junction, Pt 1000 or Ni 1000
  • The channels are parameterized independently of one another via the bus system
  • Internal detection and compensation of cold junction temperature (can be parameterized)
  • Absolute and differential temperature measurement (can be parameterized)
  • Pt 1000 sensor in the vicinity of the connection terminal blocks of the thermocouple inputs for internal measurement of the cold junction temperature
  • Measured values can be represented in three different formats
Technical Specifications

Dimensions

Width12.2 mm
Height136.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Utilization restriction

CCCex noteUse in potentially explosive areas is not permitted in China.

Inline local bus

Number of interfaces2
Connection MethodInline data jumper
Transmission Speed500 kbps

Module

ID code (dec.)127
ID code (hex)7F
Length code (hex)02
Length code (dec)02
Process data channel32 bit
Input address area4 Byte
Output address area4 Byte
Register length32 bit
Required parameter data 6 Byte
Required configuration data 4 Byte

Analog

Input nameAnalog UTH inputs
Description of the inputInputs for thermocouples or linear voltage
Number of Inputs2 (Thermocouples or linear voltage)
Connection MethodInline connector
Connection technology2-conductor
Note regarding the connection technologyShielded compensating line for TC with encapsulated sensors
A/D conversion timetyp. 120 µs (per channel)
Sensor types that can be used (TC)U, T, L, J, E, K, N, S, R, B, C, W, HK
Measuring PrincipleSuccessive approximation
Measured value representation16 bits (15 bits + sign bit)
Process data updatemax. 30 ms (For both channels)
Protective circuitSurge protection (TC channels); up to ±40 V

Product properties

Product familyInline
Typemodular
Scope of deliveryincluding Inline connector and labeling field
Operating modeProcess data operation with 2 words
Diagnostics messagesFailure of the internal I/O supply I/O error message sent to the bus coupler
Diagnostics messagesFailure of or insufficient communications power UL I/O error message sent to the bus coupler
Diagnostics messagesI/O error Error message in the process data
Diagnostics messagesUser error Error message in the process data

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition0.59 W

Potentials

Power consumptiontyp. 587 mW
Power consumptionmax. 882 mW

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 60 mA
Current drawtyp. 43 mA

Potentials: Supply of analog modules (UANA)

Supply Voltage24 V DC (via voltage jumper)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 18 mA
Current drawtyp. 11 mA

Electrical isolation/isolation of the voltage ranges

Test voltage: 7.5 V supply (bus logics)/24 V analog supply (analog I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic)/functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V analog supply (analog I/O)/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2861386?

Proax is an authorized distributor of Phoenix Contact 2861386 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability