Official Distributor
SKU
MPN
MINI-PS- 12- 24DC/24DC/1
Weight
0.235 kg
Series MINI-PS
MINI-PS- 12- 24DC/24DC/1 - DC/DC converter
Please use the following items in new systems: 1066703, 1066716, 1066718, 1066714.Primary-switched MINI DC/DC converter for DIN rail mounting, input: 12 - 24 V DC, output: 24 V DC/1 A
- Electrical isolation: for setting up independent supply systems
- Support conversion to various voltage levels
- Constant voltage: output voltage regenerated even at the end of long cables
Technical Specifications
DC operation
Nominal input voltage range | 12 V DC ... 24 V DC |
Input voltage range | 10 V DC ... 32 V DC |
Wide-range input | yes |
Input voltage range DC | 10 V DC ... 32 V DC |
Voltage type of supply voltage | DC |
Inrush Current | < 15 A (typical) |
Inrush current integral (I2t) | 1.8 A2s |
Frequency range DC | 0 Hz |
Mains buffering time | typ. 3 ms (12 V DC) |
Mains buffering time | typ. 20 ms (24 V DC) |
Current consumption | 2.6 A (12 V DC) |
Current consumption | 1.3 A (24 V DC) |
Typical response time | < 0.5 s |
Input fuse | 6.3 A (slow-blow, internal) |
Output data
Efficiency | > 83 % (at 24 V DC and nominal values) |
Output characteristic | U/I |
Nominal Output Voltage | 24 V DC ±1 % |
Setting range of the output voltage (USet) | 22.5 V DC ... 28.5 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (IN) | 1 A (-25 °C ... 60 °C) |
Derating | 60 °C ... 70 °C (2.5 %/K) |
Residual ripple | < 30 mVPP (20 MHz) |
Output Power | 24 W |
Peak switching voltages nominal load | < 100 mVPP (20 MHz) |
Maximum no-load power dissipation | < 1.2 W |
Power loss nominal load max. | < 5 W |
Connection in parallel | yes, for assembling redundant systems and increasing efficiency |
Connection in series | yes |
Signal: DC OK active
Output description | UOUT > 21.5 V: High signal |
Maximum Switching Voltage | ≤ 24 V DC |
Output Voltage | + 24 V (Signal) |
Continuous load current | ≤ 20 mA |
Input
Connection Method | Pluggable screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 7 mm |
Screw thread | M3 |
Output
Connection Method | Pluggable screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 7 mm |
Screw thread | M3 |
Signal
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Signaling
Types of signaling | LED |
Types of signaling | Active switching output |
Operating voltage display | Green LED |
Signal output: DC OK active
Status display | "DC OK" LED green |
Electrical properties
Number of phases | 1.00 |
Insulation voltage input/output | 1.5 kV (type test) |
Insulation voltage input/output | 1 kV (routine test) |
Product properties
MTBF (IEC 61709, SN 29500) | > 2569000 h (40 °C) |
Insulation characteristics
Protection class | III |
Dimensions
Width | 22.5 mm |
Height | 99 mm |
Depth | 107 mm |
Installation dimensions
Installation distance right/left | 0 mm / 0 mm (≤ 70 °C) |
Installation distance top/bottom | 50 mm / 50 mm (≤ 70 °C) |
Mounting
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
Mounting Position | horizontal DIN rail NS 35, EN 60715 |
With protective coating | No |
Material specifications
Housing Material | Plastic |
Type of housing | Polyamide PA, color: green |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Standards and Regulations
Rail applications | EN 50121-4 |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard - Safe isolation | DIN VDE 0106-101 |
Approvals
Shipbuilding approval | DNV GL (EMC A) |
UL approvals | UL/C-UL listed UL 508 |
UL approvals | UL/C-UL Recognized UL 60950-1 |
UL approvals | UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 (EN 55022) |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Housing | > Level 3 |
Contact discharge | 8 kV (Contact discharge) |
Discharge in air | 8 kV (Air discharge) |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 3 GHz |
Test field strength | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 4 kV (level 4 - asymmetrical: conductor to ground) |
Output | 2 kV (level 3 - asymmetrical: conductor to ground) |
Signal | 1 kV |
Comments | Level 2 - asymmetrical cable to ground |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 2 kV (Level 3) |
Input | 1 kV (Level 3) |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Input/Output | Level 3 |
Frequency Range | 0.15 MHz ... 80 MHz (10 V) |
Voltage dips
Standards/regulations | EN 61000-4-11 |
Emitted interference
Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Why Proax for Phoenix Contact 2866284?
Proax is an authorized distributor of Phoenix Contact 2866284 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- MINI-PS-100-240AC/24DC/4, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions.
- MINI-PS-100-240AC/10-15DC/8, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions.
- MINI-PS-100-240AC/2X15DC/1, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions.
- MINI-PS-100-240AC/ 5DC/3, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions.