Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
MINI-PS-100-240AC/2X15DC/1
Weight
0.325 kg
Series MINI-PS

MINI-PS-100-240AC/2X15DC/1 - Power supply unit

Please use the following item in new systems: 2904596Primary-switched MINI POWER power supply for DIN rail mounting, input: 1-phase, output: 2 x 15 V DC / 1 A

  • Easy-maintenance connection technology thanks to keyed COMBICON connectors
  • Remote monitoring of output voltage via switching output
Technical Specifications

AC operation

Nominal input voltage range100 V AC ... 240 V AC
Input voltage range85 V AC ... 264 V AC
Input voltage range90 V DC ... 350 V DC
Input Voltage Range AC85 V AC ... 264 V AC
Input voltage range DC90 V DC ... 350 V DC
Voltage type of supply voltageAC/DC
Inrush Current< 35 A (typical)
Inrush current integral (I2t)4 A2s
AC frequency range45 Hz ... 65 Hz
Mains buffering timetyp. 30 ms (120 V AC)
Mains buffering timetyp. 150 ms (230 V AC)
Current consumption0.6 A (120 V AC)
Current consumption0.4 A (230 V AC)
Current consumption0.8 A (90 V DC)
Current consumption0.3 A (350 V DC)
Nominal Power Consumption61 VA
Typical response time< 1 s
Input fuse2.5 A (slow-blow, internal)
Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)

Output data

Efficiency> 80 % (for 230 V AC and nominal values)
Nominal Output Voltage± 15 V DC ±1 %
Nominal output current (IN)2x 1 A (-25 °C ... 60 °C)
POWER BOOST (IBoost)2x 1.5 A (-25 °C ... 40 °C permanent)
Derating60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance17 V DC
Active current limitationApprox 4.4 A (in the event of a short circuit)
Control deviation< 2 % (change in load, static 10 % ... 90 %)
Control deviation< 3 % (change in load, dynamic 10 % ... 90 %)
Control deviation< 0.1 % (change in input voltage ±10 %)
Residual ripple< 30 mVPP (20 MHz)
Output Power15 W
Peak switching voltages nominal load< 20 mVPP (20 MHz)
Maximum no-load power dissipation2 W
Power loss nominal load max.8 W
Rise time< 100 ms (typ.)
Connection in parallelyes, for assembling redundant systems and increasing efficiency
Connection in seriesyes

Input

Connection MethodPluggable screw connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Output

Connection MethodPluggable screw connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signal

Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM3

Signaling

Types of signalingLED
Operating voltage displayGreen LED

Signal output: DC OK active

Status display"DC OK" LED green

Electrical properties

Insulation voltage input/output4 kV (type test)
Insulation voltage input/output3 kV (routine test)

Product properties

Product familyMINI POWER
MTBF (IEC 61709, SN 29500)> 500000 h (40 °C)

Insulation characteristics

Protection classII (in closed control cabinet)
Degree of pollution2

Dimensions

Width45 mm
Height99 mm
Depth107 mm

Installation dimensions

Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm

Mounting

Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm
Mounting Positionhorizontal DIN rail NS 35, EN 60715
With protective coatingNo

Material specifications

Housing MaterialPlastic
Type of housingPolyamide PA, color: green

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Vibration (Operation)15 Hz ... 150 Hz, 2.3g, 90 min.

Standards and Regulations

Rail applicationsEN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard – Safety extra-low voltageEN 60950-1 (SELV)
Standard – Safety extra-low voltageEN 60204 (PELV)
Standard - Safe isolationDIN VDE 0100-410

Approvals

UL approvalsUL/C-UL listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1
UL approvalsUL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
UL approvalsNEC Class 2 as per UL 1310

Conformity/Approvals

SIL in accordance with IEC 615080

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011 (EN 55022)

Electrostatic discharge

Standards/regulationsEN 61000-4-2
HousingLevel 3
Contact discharge8 kV
Discharge in air8 kV
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength10 V/m
Frequency Range1 GHz ... 2 GHz
Test field strength3 V/m
Frequency Range2 GHz ... 2.7 GHz
Test field strength1 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input4 kV (level 4 - asymmetrical: conductor to ground)
Output2 kV (level 3 - asymmetrical: conductor to ground)
Signal1 kV (level 2 - asymmetrical: conductor to ground)
CommentsCriterion B

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input4 kV (level 4 - asymmetrical: conductor to ground)
Input2 kV (level 4 - symmetrical: conductor to conductor)
Output0.5 kV (level 1 - asymmetrical: conductor to ground)
Output0.5 kV (level 1 - symmetrical: conductor to conductor)
Signal0.5 kV (level 1 - asymmetrical: conductor to ground)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/SLevel 3 - asymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V

Voltage dips

Standards/regulationsEN 61000-4-11

Emitted interference

Standards/regulationsEN 61000-6-3
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

Why Proax for Phoenix Contact 2938743?

Proax is an authorized distributor of Phoenix Contact 2938743 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability