2938837
SKU
PHX2938837
MPN
MINI-PS-100-240AC/24DC/4
Weight
0.496 kg
Series MINI-PS
MINI-PS-100-240AC/24DC/4 - Power supply unit
Please use the following items in new systems: 2904599 or 2909577Primary-switched MINI POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/4 A
- Easy-maintenance connection technology thanks to keyed COMBICON connectors
- Remote monitoring of output voltage via switching output
Technical Specifications
AC operation
| Nominal input voltage range | 100 V AC ... 240 V AC | 
| Input voltage range | 85 V AC ... 264 V AC | 
| Input voltage range | 90 V DC ... 350 V DC | 
| Input Voltage Range AC | 85 V AC ... 264 V AC | 
| Input voltage range DC | 90 V DC ... 350 V DC | 
| Voltage type of supply voltage | AC/DC | 
| Inrush Current | < 15 A (typical) | 
| Inrush current integral (I2t) | 2.1 A2s | 
| AC frequency range | 45 Hz ... 65 Hz | 
| Mains buffering time | > 20 ms (120 V AC) | 
| Mains buffering time | > 100 ms (230 V AC) | 
| Current consumption | 1.3 A (120 V AC) | 
| Current consumption | 0.8 A (230 V AC) | 
| Current consumption | 1.3 A (90 V DC) | 
| Current consumption | 0.4 A (350 V DC) | 
| Nominal Power Consumption | 158 VA | 
| Protective circuit | Transient surge protection; Varistor | 
| Typical response time | < 0.4 s | 
| Input fuse | 3.15 A (slow-blow, internal) | 
| Recommended breaker for input protection | 6 A ... 16 A (Characteristics B, C, D, K) | 
Output data
| Efficiency | > 88 % (for 230 V AC and nominal values) | 
| Output characteristic | U/I | 
| Nominal Output Voltage | 24 V DC ±1 % | 
| Setting range of the output voltage (USet) | 22.5 V DC ... 28.5 V DC (> 24 V DC, constant capacity restricted) | 
| Nominal output current (IN) | 4 A (-25 °C ... 60 °C) | 
| POWER BOOST (IBoost) | 5 A (-25 °C ... 40 °C permanent) | 
| Derating | 60 °C ... 70 °C (2.5 %/K) | 
| Feedback voltage resistance | 35 V DC | 
| Protection against overvoltage at the output (OVP) | ≤ 35 V DC | 
| Starting delay with capacitive load | unrestricted | 
| Max. capacitive load | unlimited | 
| Active current limitation | approx 9 A (in the event of a short-circuit) | 
| Control deviation | change in load, static 10 % ... 90 % | 
| Control deviation | < 3 % (change in load, dynamic 10 % ... 90 %) | 
| Control deviation | < 0.1 % (change in input voltage ±10 %) | 
| Residual ripple | < 20 mVPP (20 MHz) | 
| Output Power | 96 W | 
| Peak switching voltages nominal load | < 100 mVPP (20 MHz) | 
| Maximum no-load power dissipation | 2.5 W | 
| Power loss nominal load max. | 12 W | 
| Rise time | < 1.2 ms | 
| Connection in parallel | yes, for redundancy and increased capacity | 
| Connection in series | yes | 
Signal: DC OK, status indicator
| Output description | UOUT > 21.5 V: High signal | 
| Maximum Switching Voltage | ≤ 24 V | 
| Output Voltage | + 24 V (Signal) | 
| Continuous load current | ≤ 20 mA | 
Input
| Connection Method | Pluggable screw connection | 
| Conductor cross section, rigid min. | 0.2 mm² | 
| Conductor cross section, rigid max. | 2.5 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 2.5 mm² | 
| Conductor cross section AWG min. | 24 | 
| Conductor cross section AWG max. | 12 | 
| Stripping length | 7 mm | 
| Screw thread | M3 | 
Output
| Connection Method | Pluggable screw connection | 
| Conductor cross section, rigid min. | 0.2 mm² | 
| Conductor cross section, rigid max. | 2.5 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 2.5 mm² | 
| Conductor cross section AWG min. | 24 | 
| Conductor cross section AWG max. | 12 | 
| Stripping length | 7 mm | 
| Screw thread | M3 | 
| Tightening torque, min | 0.5 Nm | 
| Tightening torque max | 0.6 Nm | 
Signal
| Connection Method | Pluggable screw connection | 
| Conductor cross section, rigid min. | 0.2 mm² | 
| Conductor cross section, rigid max. | 2.5 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 2.5 mm² | 
| Conductor cross section AWG min. | 24 | 
| Conductor cross section AWG max. | 12 | 
| Screw thread | M3 | 
| Tightening torque, min | 0.5 Nm | 
| Tightening torque max | 0.6 Nm | 
Signaling
| Types of signaling | LED | 
| Types of signaling | Active switching output | 
| Operating voltage display | Green LED | 
Signal output: DC OK, status indicator
| Status display | "DC OK" LED green | 
| Note on status display | UOUT > 21.5 V: LED lights up | 
Electrical properties
| Insulation voltage input/output | 3 kV (type test) | 
| Insulation voltage input/output | 3 kV (routine test) | 
Product properties
| Product family | MINI POWER | 
| MTBF (IEC 61709, SN 29500) | > 815000 h (40 °C) | 
Insulation characteristics
| Protection class | II (in closed control cabinet) | 
| Overvoltage category | III | 
| Degree of pollution | 2 | 
Dimensions
| Width | 67.5 mm | 
| Height | 99 mm | 
| Depth | 107 mm | 
Installation dimensions
| Installation distance right/left | 0 mm / 0 mm | 
| Installation distance top/bottom | 50 mm / 50 mm | 
Mounting
| Mounting Type | DIN rail mounting | 
| Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm | 
| Mounting Position | horizontal DIN rail NS 35, EN 60715 | 
| With protective coating | No | 
Material specifications
| Housing Material | Plastic | 
| Type of housing | Polyamide PA, color: green | 
Ambient conditions
| Degree of Protection | IP20 | 
| Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Climatic class | 3K3 (in acc. with EN 60721) | 
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) | 
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) | 
| Vibration (Operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) | 
| Vibration (Operation) | 15 Hz ... 150 Hz, 2.3g, 90 min. | 
Standards and Regulations
| Rail applications | EN 50121-4 | 
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) | 
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 | 
| Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) | 
| Standard – Safety extra-low voltage | EN 60950-1 (SELV) | 
| Standard – Safety extra-low voltage | EN 60204 (PELV) | 
| Standard - Safe isolation | DIN VDE 0100-410 | 
Approvals
| UL approvals | UL/C-UL listed UL 508 | 
| UL approvals | UL/C-UL Recognized UL 60950-1 | 
| UL approvals | UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | 
Conformity/Approvals
| SIL in accordance with IEC 61508 | 0 | 
EMC data
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC | 
| EMC requirements for noise emission | EN 61000-6-3 | 
| EMC requirements for noise emission | EN 61000-6-4 | 
| EMC requirements for noise immunity | EN 61000-6-1 | 
| EMC requirements for noise immunity | EN 61000-6-2 | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Noise emission | EN 55011 (EN 55022) | 
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 | 
| Housing | Level 3 | 
| Contact discharge | 8 kV | 
| Discharge in air | 8 kV | 
| Comments | Criterion B | 
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 | 
| Frequency Range | 80 MHz ... 1 GHz | 
| Test field strength | 10 V/m | 
| Frequency Range | 1 GHz ... 2 GHz | 
| Test field strength | 3 V/m | 
| Frequency Range | 2 GHz ... 2.7 GHz | 
| Test field strength | 1 V/m | 
| Comments | Criterion A | 
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 | 
| Input | 4 kV (level 4 - asymmetrical: conductor to ground) | 
| Output | 2 kV (level 3 - asymmetrical: conductor to ground) | 
| Signal | 1 kV (level 2 - asymmetrical: conductor to ground) | 
| Comments | Criterion B | 
Surge voltage load (surge)
| Standards/regulations | EN 61000-4-5 | 
| Input | 4 kV (level 4 - asymmetrical: conductor to ground) | 
| Input | 2 kV (level 4 - symmetrical: conductor to conductor) | 
| Output | 0.5 kV (level 1 - asymmetrical: conductor to ground) | 
| Output | 0.5 kV (level 1 - symmetrical: conductor to conductor) | 
| Signal | 0.5 kV (level 1 - asymmetrical: conductor to ground) | 
| Comments | Criterion B | 
Conducted interference
| Standards/regulations | EN 61000-4-6 | 
| I/O/S | Level 3 - asymmetrical | 
| Frequency Range | 0.15 MHz ... 80 MHz | 
| Comments | Criterion A | 
| Voltage | 10 V | 
Voltage dips
| Standards/regulations | EN 61000-4-11 | 
Emitted interference
| Standards/regulations | EN 61000-6-3 | 
| Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential | 
| Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential | 
Why Proax for Phoenix Contact 2938837?
Proax is an authorized distributor of Phoenix Contact 2938837 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 | 
Recommended
 MINI-PS-100-240AC/10-15DC/8, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions. MINI-PS-100-240AC/10-15DC/8, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions.
 MINI-PS-100-240AC/2X15DC/1, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions. MINI-PS-100-240AC/2X15DC/1, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions.
 MINI-PS-100-240AC/ 5DC/3, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions. MINI-PS-100-240AC/ 5DC/3, MINI POWER power supplies for MCR technologyIn measurement and control technology (MCR), modular electronics housing has become the industry standard. MINI POWER is the power supply unit to go with it. The devices are flexible, thanks to special voltages and special versions.