Series IB-IL-AI

IB IL AI 2-HART-PAC - Analog module

Inline, Analog input terminal, Analog inputs: 2, 4 mA ... 20 mA, 0 mA ... 25 mA, connection technology: 2-conductor, transmission speed in the local bus: 500 kbps, HART functionality, HART protocol transmission, degree of protection: IP20, including Inline connectors and marking fields

  • Two differential signal inputs for current sensors
  • Connection of sensors in 2-conductor technology (active and passive sensors)
  • Current ranges: 4 mA ... 20 mA, 0 mA ... 25 mA
  • Both channels preset to the 4 mA ... 20 mA measuring range and IB IL format
  • Transmission of the HART protocol with PCP
  • Measured values can be represented in three different formats
  • Resolution depends on the representation format and the measuring range
  • Measured value acquisition with a resolution of 16 bits
  • Point-to-point and multi-drop connections possible
  • Connection of a hand-held operating panel possible
  • A maximum of 5 HART devices can be connected per channel
  • Polling and burst modes
  • FDT/DTM support with AutomationXplorer+ (unavailable since 2019)
Technical Specifications

Dimensions

Width48.8 mm
Height135 mm
Depth71.5 mm

Inline local bus

Number of interfaces2
Connection MethodInline data jumper
Transmission Speed500 kbps
Transmission physicsCopper

Module

ID code (dec.)220
ID code (hex)DC
Length code (hex)02
Length code (dec)02
Process data channel32 bit
Input address area4 Byte
Output address area4 Byte
Register length64 bit
Required parameter data 9 Byte
Required configuration data 5 Byte

Analog: General

Input nameAnalog inputs
Description of the inputDifferential inputs, current
Number of Inputs2
A/D conversion timeapprox. 10 µs (bus-synchronous)
A/D converter resolution16 bit
Connection MethodInline shield connector
Connection technology2-conductor
Note regarding the connection technologyshielded
Current Input Signal4 mA ... 20 mA
Current Input Signal0 mA ... 25 mA
Input resistance current input250 Ω
Data formatsIB IL, standardized representation, PIO
Limit frequency (3 dB)25 Hz
Common mode voltage range signal - ground40 V (Between current input and functional ground)
Measuring PrincipleSuccessive approximation
Measured value resolution16 bits (15 bits + sign bit)
Measured value representation16 bit two's complement
Protective circuitSurge protection; Suppressor diode

Product properties

Product familyInline
Typemodular
Scope of deliveryincluding Inline connectors and marking fields
Operating modeProcess data operation with 2 words, PCP with 2 words
Special PropertiesHART functionality
Special PropertiesHART protocol transmission
Diagnostics messagesFailure of the internal I/O supply yes
Diagnostics messagesI/O error Error message in the process data
Diagnostics messagesUser error Error message in the process data

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Potentials

Power consumptiontyp. 1.9 W

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 110 mA
Current drawtyp. 95 mA

Potentials: Supply of analog modules (UANA)

Supply Voltage24 V DC (via voltage jumper)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 150 mA
Current drawtyp. 50 mA

Electrical isolation/isolation of the voltage ranges

Test voltage: 7.5 V supply (bus logic), 24 V supply UANA / I/O500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic), 24 V supply UANA / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: I/O/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2862149?

Proax is an authorized distributor of Phoenix Contact 2862149 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability