Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
IB IL AI 4/I-PAC
Weight
0.089 kg
Series IB-IL-AI

IB IL AI 4/I-PAC - Analog module

Inline, Analog input terminal, Analog inputs: 4, 0 mA ... 20 mA, 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field

  • 4 analog differential input channels for connecting current signals
  • Connection of sensors in 2-conductor technology
  • Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA
  • Mean-value generation of the inputs
  • Process data update of all channels in 250 µs
  • Diagnostic and status indicators
Technical Specifications

Dimensions

Width12.2 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Inline local bus

Number of interfaces2
Connection MethodInline data jumper
Transmission Speed500 kbps
Transmission physicsCopper

Module

ID code (dec.)127
ID code (hex)7F
Length code (hex)04
Length code (dec)04
Process data channel64 bit
Input address area8 Byte
Output address area8 Byte
Register length64 bit
Required parameter data 10 Byte
Required configuration data 5 Byte

Analog: General

Input nameAnalog inputs
Description of the inputDifferential inputs, current
Number of Inputs4
A/D conversion timemax. 6.5 µs
A/D converter resolution12 bit
Connection MethodInline connector
Connection technology2-conductor
Current Input Signal0 mA ... 20 mA
Current Input Signal4 mA ... 20 mA
Input resistance current inputtyp. 113 Ω
Data formatsIB IL, S7-compatible
FilteringNone or mean-value generation over 4, 16, or 32 measured values
Limit frequency (3 dB)300 Hz
Measured value resolution13 bits (12 bits + sign bit)
Measured value representation13 bits (12 bits + sign bit)

Product properties

Product familyInline
Typemodular
Scope of deliveryincluding Inline connector and labeling field
Diagnostics messagesFailure of the internal I/O supply I/O error message sent to the bus coupler
Diagnostics messagesI/O supply failure Message in the diagnostic code (in the IB IL format)
Diagnostics messagesOverrange or underrange Message in the diagnostic code (in the IB IL format)
Diagnostics messagesConfiguration invalid Message in the diagnostic code (in the IB IL format)

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition7.68 W

Potentials

Power consumptiontyp. 0.94 W (total)

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 60 mA
Current drawtyp. 55 mA

Potentials: Supply of analog modules (UANA)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 35 mA
Current drawtyp. 30 mA

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics)500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic), 24 V supply UANA / I/O500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic), 24 V supply UANA / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: I/O/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2700458?

Proax is an authorized distributor of Phoenix Contact 2700458 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability