PACT RCP-4000A-1A-D140-10M - Current transformer

Set consisting of one 1 A measuring transducer and one Rogowski coil with signal line. Length of Rogowski coil: 450 mm, diameter: 140 mm. Length of signal line: 10 m. The Rogowski coil measures the AC current of busbars and power lines.

Technical Specifications

Insulation characteristics

Insulationdouble insulation
Insulationdouble insulation
Overvoltage categoryIII (1000 V, to neutral conductor)
Overvoltage categoryIV (600 V, to neutral conductor)
Pollution degree2

Electrical properties

Electrical isolationReinforced insulation in accordance with IEC 61010-1
Typical measuring error< 1 %
Protective circuitSurge protection; 33 V suppressor diode
Temperature coefficients0.005 %/K (+10 °C ... +70 °C, both components have the same ambient temperature)
Temperature coefficients0.07 %/K (-20 °C ... +10 °C, both components have the same ambient temperature)

Measuring coil

Conductor structure signal line2x 0.22 mm (Signal (tinned))
Conductor structure signal line1x 0.22 mm (Shielding (tinned))
Insulationdouble insulation
Rated Insulation Voltage1000 V AC (rms CAT III)
Rated Insulation Voltage600 V AC (rms CAT IV)
Test voltage10.45 kV DC (60 s)
Basic accuracy<± 0.2 %

Measuring transducers

Linearity error< 0.5 % (From the range end value)
Maximum transmission error≤ 0.5 % (From the range end value)
Frequency Range45 Hz ... 65 Hz
Max. detectable harmonics< 2 kHz
Current consumption< 190 mA (at 19.2 V)
Test voltage1.5 kV AC (Supply/input and output: 50 Hz, 1 min)

General

Can be calibratedno
Class1
Accuracy class1
Converter typeRogowski coil and 1 A measuring transducer

Supply: Measuring transducers

Nominal Supply Voltage24 V DC -20 % ... +25 %
Nominal supply voltage range19.2 V DC ... 30 V DC
Max. current consumption190 mA
Power consumption4 W

Frequency

DesignationMeasuring coil
Frequency measuring range40 Hz ... 20000 Hz
Position error<± 0.1 % (typical)
Linearity error< 0.1 %

Signal

Input signal (at 50 Hz)100 mV (1000 A)
Curve typeSine
Input Impedance27 kΩ (smallest measuring range)

Current transformers

Configurable/programmableVia DIP switches
Rated power1.5 VA
Primary rated current Ipn0 A AC ... 100 A AC
Primary rated current Ipn0 A AC ... 250 A AC
Primary rated current Ipn0 A AC ... 400 A AC
Primary rated current Ipn0 A AC ... 630 A AC
Primary rated current Ipn0 A AC ... 1000 A AC
Primary rated current Ipn0 A AC ... 1500 A AC
Primary rated current Ipn0 A AC ... 2000 A AC
Primary rated current Ipn0 A AC ... 4000 A AC
Phase angle< 1 °
Can be calibratedno
Class1
Accuracy class1
Converter typeRogowski coil and 1 A measuring transducer

Signal

DesignationMeasuring coil
Output signal (at 50 Hz)100 mV (no load, at 1,000 A)
Output voltage (in no-load operation)VOUT = M * dI/dt
Output voltage (sinusoidal, in no-load operation)100 mV (VOUT = 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))
Accuracy class< 1
DesignationMeasuring transducer
Current Output Signal0 A AC ... 1 A AC
Rated power1.25 VA
Load0 Ω ... 1.25 Ω
Max. distances for copper cables at PN max16 m (0.75 mm² (AWG 20))
Max. distances for copper cables at PN max32 m (1.5 mm² (AWG 16))
Max. distances for copper cables at PN max55 m (2.5 mm² (AWG 14))

Measuring transducer side

Connection MethodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm

Signaling

Operating voltage displayGreen LED

Item dimensions

Width22.5 mm
Height85 mm
Depth70.4 mm

Measuring coil

Length450 mm
Diameter8.3 mm ±0.2 mm

Measuring coil when installed

Diameter140 mm

Signal line

Length10 m
Width22.5 mm
Height85 mm
Depth70.4 mm

Material specifications

Housing MaterialPC
Housing MaterialPolyamide
Coil materialElastollan

Ambient conditions

Measuring coil degree of protectionIP67 (not assessed by UL)
Measuring transducer degree of protectionIP20
Ambient Temperature (Operation)-30 °C ... 80 °C (Measuring coil)
Ambient Temperature (Operation)-20 °C ... 70 °C (Measuring transducer)
Ambient temperature (storage/transport)-40 °C ... 80 °C (Measuring coil)
Ambient temperature (storage/transport)-25 °C ... 85 °C (Measuring transducer)
Altitude< 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

CMIM

CertificateCMIM-compliant

UL, USA/Canada

IdentificationUL 61010 Recognized
NoteMeasuring coil
IdentificationUL 508 Listed
NoteMeasuring transducer

EMC data

Noise immunityEN 61000-6-3
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Standards and Regulations

Electrical isolationReinforced insulation in accordance with IEC 61010-1
Standards/regulationsIEC 61010-1
Standards/regulationsIEC 61010-2-032

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact PACT RCP-4000A-1A-D140-10M?

Proax is an authorized distributor of Phoenix Contact PACT RCP-4000A-1A-D140-10M and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPACTRCP4000A1AD14010M
Pack Size1
Recommended

Available for order