PACT RCP-4000A-1A - Measuring transducer
This is an individual product; please order the complete set. The measuring transducer processes the mV signal of the upstream Rogowski coil. The measuring transducer has 8 current measuring ranges (100 A ... 4000 A AC) which can be set; max. output current of 1 A AC.
Technical Specifications
Measuring transducers
Linearity error | < 0.5 % (From the range end value) |
Maximum transmission error | ≤ 0.5 % (From the range end value) |
Frequency Range | 45 Hz ... 65 Hz |
Current consumption | < 190 mA (at 19.2 V) |
Test voltage | 1.5 kV AC (Supply/input and output: 50 Hz, 1 min) |
General
Can be calibrated | no |
Class | 1 |
Converter type | Measuring transducer for Rogowski coil |
Supply: Measuring transducers
Nominal Supply Voltage | 24 V DC -20 % ... +25 % |
Nominal supply voltage range | 19.2 V DC ... 30 V DC |
Max. current consumption | 190 mA |
Power consumption | 4 W |
Signal
Input signal (at 50 Hz) | 100 mV (1000 A) |
Curve type | Sine |
Input Impedance | 27 kΩ (smallest measuring range) |
Current transformers
Configurable/programmable | Via DIP switches |
Rated power | 1.5 VA |
Primary rated current Ipn | 0 A AC ... 100 A AC |
Primary rated current Ipn | 0 A AC ... 250 A AC |
Primary rated current Ipn | 0 A AC ... 400 A AC |
Primary rated current Ipn | 0 A AC ... 630 A AC |
Primary rated current Ipn | 0 A AC ... 1000 A AC |
Primary rated current Ipn | 0 A AC ... 1500 A AC |
Primary rated current Ipn | 0 A AC ... 2000 A AC |
Primary rated current Ipn | 0 A AC ... 4000 A AC |
Phase angle | < 1 ° |
Can be calibrated | no |
Class | 1 |
Converter type | Measuring transducer for Rogowski coil |
Signal
Designation | Measuring transducer |
Current Output Signal | 0 A AC ... 1 A AC |
Load | 0 Ω ... 1.5 Ω |
Measuring transducer side
Connection Method | Screw connection |
Stripping length | 7 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Signaling
Operating voltage display | Green LED |
Item dimensions
Width | 22.5 mm |
Height | 85 mm |
Depth | 70.4 mm |
Width | 22.5 mm |
Height | 85 mm |
Depth | 70.4 mm |
Material specifications
Housing Material | Polyamide |
Ambient conditions
Measuring transducer degree of protection | IP20 |
Ambient Temperature (Operation) | -10 °C ... 65 °C (-14 °F ... 149 °F) |
Ambient Temperature (Operation) | -20 °C ... 70 °C (Measuring transducer) |
Ambient temperature (storage/transport) | -25 °C ... 85 °C (Measuring transducer) |
Altitude | < 2000 m |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
UKCA
Certificate | UKCA-compliant |
CMIM
Certificate | CMIM-compliant |
Mounting
Mounting Type | DIN rail mounting |
Why Proax for Phoenix Contact 2902990?
Proax is an authorized distributor of Phoenix Contact 2902990 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 2906232 - Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 450 mm in length/140 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
- 2906233 - Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 600 mm in length/190 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
- 2906231 - Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 300 mm in length/95 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
- 2906235 - Set consisting of a 4-way signal conditioner with push-in connection technology and a Rogowski coil 450 mm in length/140 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
- 2906236 - Set consisting of a 4-way signal conditioner with push-in connection technology and a Rogowski coil 600 mm in length/190 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.
- 2906234 - Set consisting of a 4-way signal conditioner with push-in connection technology and a Rogowski coil 300 mm in length/95 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the output side and has one switching output.