Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
MACX MCR-T-UI-UP-SP
This product is Not Cancellable/Not Returnable

MACX MCR-T-UI-UP-SP - Temperature measuring transducer

Freely programmable temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.

  • Cold junction compensation with separate plug
  • Configuration via software (FDT/DTM) or IFS-OP-UNIT operator interface and display unit
  • Up to SIL 2 in accordance with EN 61508
  • Installation in zone 2, protection type "n" (EN 60079-15) permitted
  • Inverse output signal ranges as an option
  • Plug-in screw or spring-cage connection technology (Push-in technology)
  • Programming during operation and also voltage-free using IFS-USB-PROG-ADAPTER programming adapter
  • Measure differential temperatures
  • Input for resistance thermometers, thermocouples, resistance-type sensors, potentiometers, and mV sources
  • Freely programmable input and output
  • Relay switching output
Technical Specifications

Product properties

Product familyMACX Analog
TypeSignal conditioners with SIL and PL Functional Safety
ConfigurationDIP switches
ConfigurationSoftware

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Electrical isolation4-way isolation
Maximum power dissipation for nominal condition1.26 W
Step response (0–99%)≤ 1.75 s (SIL on)
Step response (0–99%)1.3 s (SIL off)
Maximum temperature coefficient0.01 %/K

Electrical isolation Input/output/power supply

Rated Insulation Voltage300 Vrms
Test voltage2.5 kV AC (50 Hz, 60 s)
InsulationSafe isolation in accordance with IEC/EN 61010-1

Electrical isolation Input/output

Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)

Electrical isolation Input/power supply

Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)

Electrical isolation Input/switching output

Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)

Supply

Nominal supply voltage range24 V AC/DC ... 230 V AC/DC (50/60 Hz)
Supply Voltage Range19.2 V AC/DC ... 253 V AC/DC (24 V AC/DC ... 230 V AC/DC (-20 % ... +10 %, 50/60 Hz))
Power consumption< 1.5 W

Signal

Number of Inputs1
Input SignalTemperature
Input SignalResistor
Input SignalVoltage

Measurement

Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
Linear resistance measuring range0 Ω ... 50 kΩ
Potentiometer resistance range0 Ω ... 50 kΩ
Linear mV signal range-1000 mV ... 1000 mV

Switching: Relay

Configurable/programmableYes
Contact switching type1 changeover contact
Contact MaterialAgSnO2, hard gold-plated
Maximum Switching Voltage30 V AC (30 V DC)
Max. switching current0.5 A (30 V AC)
Max. switching current1 A (30 V DC)

Signal: Current

Number of Outputs1
Configurable/programmableYes
Max. voltage output signal± 11 V
Current Output Signal4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
Max. current output signal22 mA
Load/output load voltage output≥ 10 kΩ
Load/Output Load Current Output≤ 600 Ω (20 mA)
Behavior in the event of a sensor erroraccording to NE 43 or freely configurable

Connection data

Connection MethodPush-in connection
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2

Signaling

Error indicationRed LED

Dimensions

Width17.5 mm
Height116 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing MaterialPA 6.6-FR

Ambient conditions

Ambient Temperature (Operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)typ. 5 % ... 95 % (non-condensing)

Altitude range (≤ 2000 m)

Altitude≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.)

Altitude range (≤ 3000 m)

Height Range> 2000 m ... 3000 m
Ambient Temperature (Operation)-20 °C ... 55 °C

Altitude range (≤ 4000 m)

Height Range> 3000 m ... 4000 m
Ambient Temperature (Operation)-20 °C ... 50 °C

Altitude range (≤ 5000 m)

Height Range> 4000 m ... 5000 m
Ambient Temperature (Operation)-20 °C ... 45 °C

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex ec ic nC IIC T4 Gc
CertificatePxCIF20ATEX2811378

UKCA Ex (UKEX)

Identification II 3 G Ex ec ic nC IIC T4 Gc X
CertificateCML 22UKEX3529X

IECEx

IdentificationEx ec ic nC IIC T4 Gc
CertificateIECEx IBE 10.0004 X

UL, USA/Canada

IdentificationUL 508 Listed
IdentificationClass I, Div. 2, Groups A, B, C, D T6
IdentificationClass I, Zone 2, Group IIC T6

Shipbuilding approval

CertificateDNV GL TAA000020C

Safety Integrity Level (SIL, IEC 61508)

Identification2
CertificateSEBS-A.150520/17TB

Performance Level (ISO 13849)

Identificationd

INMETRO

IdentificationEx ec ic nC IIC T4 Gc
CertificateDNV 18.0143 X

EAC Ex

Identification 2Ex ec ic IIC T4 Gc
CertificateBY/112 02.01 TP012 103.01 00078

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Standards and Regulations

Electrical isolation4-way isolation

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2811860?

Proax is an authorized distributor of Phoenix Contact 2811860 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability