SKU
MPN
MACX MCR-T-UIREL-UP-SP
Weight
0.343 kg
This product is Not Cancellable/Not Returnable
MACX MCR-T-UIREL-UP-SP - Temperature measuring transducer
Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL.
- Cold junction compensation with separate plug
- Configuration via software (FDT/DTM) or IFS-OP-UNIT operator interface and display unit
- Installation in zone 2, protection type "n" (EN 60079-15) permitted
- Up to SIL 2 in accordance with EN 61508
- Plug-in screw or spring-cage connection technology (Push-in technology)
- Three limit value relays, can be used in combination as a safe limit value relay
- Programming during operation and also voltage-free using IFS-USB-PROG-ADAPTER programming adapter
- Input for resistance thermometers, thermocouples, resistance-type sensors, potentiometers, and mV sources
- Measure differential temperatures
- Freely programmable input and output
- Inverse output signal ranges as an option
Technical Specifications
Product properties
Product family | MACX Analog |
Type | Signal conditioners with SIL and PL Functional Safety |
Configuration | DIP switches |
Configuration | Software |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Electrical isolation | 4-way isolation |
Step response (0–99%) | ≤ 1.75 s (SIL on) |
Step response (0–99%) | 1.3 s (SIL off) |
Maximum temperature coefficient | 0.01 %/K |
Maximum transmission error | 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA) |
Electrical isolation Input/output/power supply
Rated Insulation Voltage | 300 Vrms |
Test voltage | 2.5 kV AC (50 Hz, 60 s) |
Insulation | Safe isolation in accordance with IEC/EN 61010-1 |
Electrical isolation Input/output
Electrical isolation | 375 V (Peak value in accordance with IEC/EN 60079-11) |
Electrical isolation Input/power supply
Electrical isolation | 375 V (Peak value in accordance with IEC/EN 60079-11) |
Electrical isolation Input/switching output
Electrical isolation | 375 V (Peak value in accordance with IEC/EN 60079-11) |
Supply
Nominal supply voltage range | 24 V AC/DC ... 230 V AC/DC (50/60 Hz) |
Supply Voltage Range | 19.2 V AC/DC ... 253 V AC/DC (24 V AC/DC ... 230 V AC/DC (-20 % ... +10 %, 50/60 Hz)) |
Power consumption | < 2.4 W |
Signal
Number of Inputs | 1 |
Input Signal | Temperature |
Input Signal | Resistor |
Input Signal | Voltage |
Measurement
Sensor types (RTD) that can be used | Pt, Ni, Cu sensors: 2, 3, 4-wire |
Sensor types that can be used (TC) | B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG |
Temperature measuring range | -250 °C ... 2500 °C (Range depending on the sensor type) |
Linear resistance measuring range | 0 Ω ... 50 kΩ |
Potentiometer resistance range | 0 Ω ... 50 kΩ |
Linear mV signal range | -1000 mV ... 1000 mV |
Switching: Relay
Configurable/programmable | Yes |
Contact switching type | 3 changeover contacts |
Contact Material | AgSnO2, hard gold-plated |
Maximum Switching Voltage | 250 V AC (250 V DC) |
Max. switching current | 2 A (250 V AC) |
Max. switching current | 0.1 A (250 V DC) |
Max. switching current | 2 A (28 V DC) |
Signal: Current
Number of Outputs | 1 |
Configurable/programmable | Yes |
Max. voltage output signal | ± 11 V |
Current Output Signal | 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL) |
Max. current output signal | 22 mA |
Load/output load voltage output | ≥ 10 kΩ |
Load/Output Load Current Output | ≤ 600 Ω (20 mA) |
Behavior in the event of a sensor error | according to NE 43 or freely configurable |
Connection data
Connection Method | Push-in connection |
Stripping length | 8 mm |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Ex data
Ex installation (EPL) | Gc |
Ex installation (EPL) | Div. 2 |
Signaling
Error indication | Red LED |
Dimensions
Width | 35 mm |
Height | 116 mm |
Depth | 113.7 mm |
Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Housing Material | PA 6.6-FR |
Ambient conditions
Ambient Temperature (Operation) | -20 °C ... 65 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | typ. 5 % ... 95 % (non-condensing) |
Altitude range (≤ 2000 m)
Altitude | ≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.) |
Altitude range (≤ 3000 m)
Height Range | > 2000 m ... 3000 m |
Ambient Temperature (Operation) | -20 °C ... 55 °C |
Altitude range (≤ 4000 m)
Height Range | > 3000 m ... 4000 m |
Ambient Temperature (Operation) | -20 °C ... 50 °C |
Altitude range (≤ 5000 m)
Height Range | > 4000 m ... 5000 m |
Ambient Temperature (Operation) | -20 °C ... 45 °C |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex ec ic nC IIC T4 Gc |
Certificate | PxCIF20ATEX2811378 |
UKCA Ex (UKEX)
Identification | II 3 G Ex ec ic nC IIC T4 Gc X |
Certificate | CML 22UKEX3529X |
IECEx
Identification | Ex ec ic nC IIC T4 Gc |
Certificate | IECEx IBE 10.0004 X |
UL, USA/Canada
Identification | UL 508 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T6 |
Identification | Class I, Zone 2, Group IIC T6 |
Shipbuilding approval
Certificate | DNV GL TAA000020C |
Safety Integrity Level (SIL, IEC 61508)
Identification | 2 |
Performance Level (ISO 13849)
Identification | d |
INMETRO
Identification | Ex ec ic nC IIC T4 Gc |
Certificate | DNV 18.0143 X |
EAC Ex
Identification | 2Ex ec ic IIC T4 Gc |
Certificate | BY/112 02.01 TP012 103.01 00078 |
DNV GL data
Temperature | B |
Humidity | B |
Vibration | A |
EMC | A |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Standards and Regulations
Electrical isolation | 4-way isolation |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2811828?
Proax is an authorized distributor of Phoenix Contact 2811828 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |