Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
QUINT-UPS/ 24DC/12DC/5/24DC/10
Weight
0.735 kg
Series QUINT-UPS

QUINT-UPS/ 24DC/12DC/5/24DC/10 - Uninterruptible power supply

Uninterruptible power supply with IQ technology for DIN rail mounting, input: 24 V DC, output: 24 V DC/10 A and 12 V DC/5 A, including mounted universal DIN rail adapter UTA 107/30

  • Easy handling thanks to automatic battery detection, tool-free battery replacement during operation, and communication via the IFS interface
  • Optimum use of the buffer time and preventive monitoring of the energy storage
  • Rapid battery charging
  • Comprehensive signaling and parameterization
  • Fast tripping of standard circuit breakers with SFB (selective fuse breaking) technology
  • Optimum protection with dip coating for 100 % humidity
  • One UPS module - two voltages
  • Maximum flexibility, thanks to the dual output
Technical Specifications

DC operation

Input Voltage24 V DC
Nominal input voltage range18 V DC ... 30 V DC
Input voltage range18 V DC ... 30 V DC
Input voltage range DC18 V DC ... 30 V DC
Voltage type of supply voltageDC
Buffer period3 h (With battery module 38 AH)
Current consumption16 A (maximum, mains operation)
Current consumption104 mA (No load, mains operation)
Current consumption4 A (Charging, mains operation)
Fixed backup threshold≤ 22 V DC
Variable connect threshold1 V/0.1 s
Recommended breaker for input protection16 A ... 20 A (Characteristic B)

Output data

Efficiency> 98 % (Mains operation, with charged energy storage)
Efficiency> 93 % (Mains operation, with charged energy storage)
Nominal Output Voltage24 V DC
Output voltage range18 V DC ... 30 V DC (UOUT = UIN - 0.5 V DC)
Nominal output current (IN)10 A (-25 °C ... 60 °C)
Nominal output current (IN)5 A (-25 °C ... 60 °C)
Output current limitIn mains mode according to connected upstream current limiting device
Output current limit> 15 A (Battery operation)
Bridging time10800 s
Derating60 °C ... 70 °C (2.5 %/K)
Derating60 °C ... 70 °C (2.5 %/K)
UPS connection in parallelyes
UPS connection in seriesno
Output Power240 W
Total power P12V + P24Vmax. 360 W
Power dissipation2.6 W (Mains operation)
Power dissipation4.6 W (Mains operation)
Power dissipation2.9 W (Battery operation)
Power dissipation5.27 W (Battery operation)
Connection in parallelyes, up to 2 modules with redundancy module
Connection in parallel2 (Devices)
Connection in seriesNo
Connection in seriesno

Mains operation

Nominal Output Voltage12 V DC
Nominal Output Voltage24 V DC
Output voltage range18 V DC ... 30 V DC (UOUT = UIN - 0.5 V DC)
Nominal output current (IN)5 A (-25 °C ... 60 °C)
Nominal output current (IN)10 A (-25 °C ... 60 °C)
POWER BOOST (IBoost)7.5 A (-25 °C ... 40 °C)
POWER BOOST (IBoost)15 A (-25 °C ... 40 °C)
Selective Fuse Breaking (ISFB)60 A (-25 °C ... 60 °C)
Duration12 ms (SFB technology)

Battery operation

Nominal Output Voltage12 V DC
Nominal Output Voltage24 V DC
Output voltage range19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
Nominal output current (IN)5 A (-25 °C ... 60 °C)
Nominal output current (IN)10 A (-25 °C ... 60 °C)
POWER BOOST (IBoost)7.5 A (-25 °C ... 40 °C)
POWER BOOST (IBoost)15 A (-25 °C ... 40 °C)
Selective Fuse Breaking (ISFB)65 A (-25 °C ... 60 °C)
Duration15 ms (SFB technology)

Signal: Alarm

Output descriptionRelay (floating)
Maximum Switching Voltage≤ 30 V AC/DC
Continuous load current≤ 100 mA

Signal: Battery charge

Output descriptionRelay (floating)
Maximum Switching Voltage≤ 30 V AC/DC
Output Voltage24 V
Continuous load current≤ 100 mA

Signal: Battery mode

Output descriptionRelay (floating)
Maximum Switching Voltage≤ 30 V AC/DC
Output Voltage24 V
Continuous load current≤ 100 mA

Signal: POWER BOOST

Output Voltage24 V DC
Continuous load current100 mA

Energy storage

Nominal voltage UN24 V DC
End-of-charge voltage24 V DC ... 29 V DC (temperature compensated)
Charging current0.2 A ... 2.88 A
Nominal capacity range1.3 Ah ... 60 Ah
Battery presence check/time interval1 min.
Battery presence check (cyclic)60 s
Energy storage device connection in parallelyes, 15 (observe line protection)
Energy storage device connection in seriesno
IQ TechnologyYes
Temperature compensation42 mV/K (preset)
Temperature compensation (preset)42 mV/K
Network managementYes

Input

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.16
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM4
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Output

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.16
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM4
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signal

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM4
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Interfaces

InterfaceIFS (Interface system data port)

Signaling

Types of signalingLED
Types of signalingRelay contact
Types of signalingInterface/software

Signal output

Signalization designationPower In OK
Status displayLED
Note on status displaystatic on
Note on status displaystatic on

Signal output: Switching output

Signalization designationAlarm
Status displayLED
Note on status displaystatic on
Colorred
Note on status displaystatic on
Signalization designationBattery charge
Status displayLED bar graph
Note on status displaydynamic
Colorred/green
Note on status displaydynamic
Signalization designationBattery mode
Status displayLED
Note on status displaystatic on
Coloryellow
Note on status displaystatic on

Signal output: Transistor output, active

Signalization designationPOWER BOOST

Electrical properties

Insulation voltage input/output500 V DC
Insulation voltage input, output / housing750 V DC

Product properties

Product familyQUINT USV
IQ TechnologyYes
MTBF (IEC 61709, SN 29500)> 652000 h (40 °C)

Insulation characteristics

Protection classIII

Life expectancy (electrolytic capacitors)

Time33941 h

Dimensions

Width35 mm
Height130 mm
Depth125 mm

Installation dimensions

Installation distance right/left5 mm / 5 mm
Installation distance top/bottom50 mm / 50 mm

Alternative assembly

Width123 mm
Height130 mm
Depth39 mm

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: horizontal 5 mm, vertical 50 mm
Mounting Positionhorizontal DIN rail NS 35, EN 60715

Material specifications

Housing MaterialMetal
Housing MaterialSteel sheet, zinc-plated
Type of housingAluminum (AlMg3)
Hood versionGalvanized sheet steel, free from chrome (VI)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Vibration (Operation)15 Hz ... 150 Hz, 2.3g tv = 90 min.

Standards and Regulations

Rail applicationsEN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)

Approvals

UL approvalsUL Listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength20 V/m
Frequency Range1 GHz ... 2 GHz
Test field strength10 V/m
Frequency Range2 GHz ... 3 GHz
Test field strength3 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input2 kV (Test Level 3 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input0.5 kV (Test Level 1 - symmetrical)
Input0.5 kV (Test Level 1 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Emitted interference

Standards/regulationsEN 61000-6-3
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Accessories

Why Proax for Phoenix Contact 2320461?

Proax is an authorized distributor of Phoenix Contact 2320461 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability