Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2320270
Weight
2.51 kg
Series QUINT-UPS

QUINT-UPS/ 1AC/ 1AC/500VA - Uninterruptible power supply

Uninterruptible power supply with IQ technology 1AC/1AC/500 VA. For 120 V AC/230 V AC applications. Provides information regarding the charging state, remaining runtime, and service life of your rechargeable battery module at all times and thereby increases system availability.

  • Optimum use of the buffer time and preventive monitoring of the energy storage
  • Can be used worldwide
  • Maximum efficiency
  • Comprehensive signaling and parameterization
  • Simplified startup
Technical Specifications

AC operation

Input Voltage240 V AC
Input Voltage100 V AC
Input Voltage120 V AC -20 % / +15 %
Input Voltage230 V AC -20 % / +15 %
Nominal input voltage range100 V AC ... 240 V AC
Input voltage range184 V AC ... 264 V AC
Input voltage range96 V AC ... 138 V AC
Input voltage range96 V AC ... 264 V AC
Input Voltage Range AC196 V AC ... 264 V AC
Input Voltage Range AC102 V AC ... 138 V AC
Input Voltage Range AC96 V AC ... 264 V AC
Voltage type of supply voltageAC
Nominal frequency50 Hz ... 60 Hz
Nominal frequency50 Hz ... 60 Hz
AC frequency range45 Hz ... 65 Hz
Buffer period1 h (38 AH)
Current consumption2.2 A (230 V AC)
Current consumption0.18 A (230 V AC)
Current consumption0.8 A (230 V AC)
Current consumption3.7 A (230 V AC)
Current consumption4.3 A (120 V AC)
Current consumption0.35 A (120 V AC)
Current consumption1.3 A (120 V AC)
Current consumption6.8 A (120 V AC)
Fixed backup thresholdConfigurable, 10% deviation from nominal input voltage set by default
Variable connect thresholdCan be configured using UPS-CONF software
Power factor (cos phi)0.8
Device mains fuse10 A
Permissible backup fuseB16 230 V AC
Permissible backup fuse20 A 120 V AC, Listed breaker

Digital Control Low-Active (configurable)

Battery-operated start 120 V AC DefaultPlug-in bridge (output +24 V DC, 30 mA to input A1)
Battery-operated start 230 V AC DefaultPlug-in bridge (output +24 V DC, 30 mA to input A2)

Output data

Classification according to IEC 62040-3VFD-SS-311
Efficiency> 98 % (Mains operation)
Efficiency> 98 % (120 V AC)
Efficiency> 86 % (Battery operation)
Nominal Output Voltage120 V AC
Nominal Output Voltage230 V AC
Output voltage range96 V AC ... 144 V AC
Output voltage range184 V AC ... 264 V AC
Form of output voltagePure sine
Nominal output current (IN)4.3 A (120 V AC, -25 °C ... 50 °C)
Nominal output current (IN)2.2 A (230 V AC, -25°C ... 40°C)
Output current limit5.2 A (120 V AC)
Output current limit2.7 A (230 V AC)
POWER BOOST (IBoost)5.2 A (120 V AC, -25 °C ... 40 °C)
POWER BOOST (IBoost)2.7 A (230 V AC, -25°C ... 40°C)
Bridging time3600 s
Derating> 50 °C ... 70 °C (2.5 %/K)
UPS connection in parallelno
UPS connection in seriesno
Output Power516 W
Apparent power500 VA
Nominal power400 W
Crest factor2.8
Switch-over time< 10 ms
Connection in parallelno
Connection in seriesNo

Mains operation

Nominal Output Voltage120 V AC
Nominal Output Voltage230 V AC
Output voltage range102 V AC ... 138 V AC
Output voltage range196 V AC ... 264 V AC
Nominal output current (IN)4.3 A (120 V AC)
Nominal output current (IN)2.2 A (230 V AC)
POWER BOOST (IBoost)5.2 A
POWER BOOST (IBoost)2.7 A
Permissible backup fuseAC: 1 x circuit breaker - recommended fuse

Battery operation

Nominal Output Voltage120 V AC
Nominal Output Voltage230 V AC
Nominal output current (IN)2.2 A (230 V AC)
Nominal output current (IN)4.3 A (120 V AC)
POWER BOOST (IBoost)2.7 A (230 V AC)
POWER BOOST (IBoost)5.2 A (120 V AC)
Permissible backup fuse25 A in parallel operation of 3.5 AH and 60 WH
Permissible backup fuse50 A in parallel operation of 7.2 AH, 12 AH, and 38 AH
Buffer period10 min. (400 W / 7,2 Ah)

Signal: Alarm

Maximum Switching Voltage≤ 30 V DC
Output Voltage24 V (SELV)
Continuous load current≤ 30 mA

Signal: Battery mode

Maximum Switching Voltage≤ 30 V DC
Output Voltage24 V (SELV)
Continuous load current≤ 30 mA

Signal: POWER BOOST

Maximum Switching Voltage≤ 30 V DC
Output Voltage24 V (SELV)
Continuous load current≤ 30 mA

Energy storage

Nominal voltage UN24 V DC
End-of-charge voltage25 V DC ... 30 V DC (temperature compensated)
Charging current2 A
Nominal capacity range3.4 Ah ... 114 Ah (3x 38 Ah)
Battery presence check/time interval1 min.
Battery presence check (cyclic)60 s
Energy storage device connection in parallelyes, 3 (observe line protection)
Energy storage device connection in seriesno
IQ TechnologyYes
Temperature compensation42 mV/K (preset)
Temperature compensation (preset)-42 mV/K
Permissible backup fuse50 A
Network managementYes

Input

Connection MethodScrew connection
Conductor cross section, rigid min.1.5 mm²
Conductor cross section, rigid max.6 mm²
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.18
Conductor cross section AWG max.10
Stripping length8 mm
Screw threadM4
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Output

Connection MethodScrew connection
Conductor cross section, rigid min.1.5 mm²
Conductor cross section, rigid max.6 mm²
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.18
Conductor cross section AWG max.10
Stripping length8 mm
Screw threadM4
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signal

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.10
Stripping length8 mm
Screw threadM4
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Interfaces

InterfaceIFS (Interface system data port)
InterfaceMINI-USB type B

Signaling

Types of signalingLED
Types of signalingActive switching outputs
Types of signalingInterface/software

Signal output: Status indicator 120 V AC

Signalization designationAC mode of operation
Status displayLED
Note on status displaystatic on

Signal output: Status indicator 230 V AC

Signalization designationAC mode of operation
Status displayLED
Colorgreen
Note on status displaystatic on

Signal output: Transistor output, active

Signalization designationAlarm
Status displayLED
Colorred
Note on status displaystatic on
Signalization designationBattery mode
Status displayLED
Coloryellow
Note on status displaystatic on
Signalization designationPOWER BOOST
Status displayLED
Coloryellow
Note on status displaystatic on

Signal output

Signalization designationBattery charge
Status displayBar graph
Colorred/green

Electrical properties

Insulation voltage input, output / housing1.5 kV AC
Insulation voltage input, output / housing2.1 kV DC

Product properties

Product familyQUINT AC-USV
IQ TechnologyYes
MTBF (IEC 61709, SN 29500)> 240513 h (40 °C)

Insulation characteristics

Protection classI

Life expectancy (electrolytic capacitors)

Time184982 h

Dimensions

Width125 mm
Height130 mm
Depth125 mm

Installation dimensions

Installation distance right/left5 mm / 5 mm
Installation distance top/bottom50 mm / 50 mm

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Mounting Positionhorizontal DIN rail NS 35, EN 60715

Material specifications

Housing MaterialMetal
Housing MaterialSteel sheet, zinc-plated
Type of housingAluminum (AlMg3)
Hood versionGalvanized sheet steel, free from chrome (VI)
Side element versionAluminum

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 50 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Vibration (Operation)15 Hz ... 150 Hz, 2.3g tv = 90 min.

Standards and Regulations

Rail applicationsEN 50121-4

Standards

Standard uninterruptible power supply systemsEN 62040-1

Uninterruptible power supply systems

Standard designationUninterruptible power supply systems
Standards/specificationsEN 62040-1

UL

IdentificationUL/C-UL Recognized UL 1778

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Interference emissionNoise emission in accordance with EN 62040-2
Noise immunityImmunity in accordance with EN 62040-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 3 GHz
Test field strength10 V/m
Frequency Range1 GHz ... 3 GHz
Test field strength10 V/m
Frequency Range2 GHz ... 3 GHz
Test field strength3 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input2 kV (Test Level 3 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input1 kV (Test Level 2 - symmetrical)
Input2 kV (Test Level 3 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Emitted interference

Radio interference voltageEN 62040-2 (Class C1)

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Accessories

Why Proax for Phoenix Contact QUINT-UPS/ 1AC/ 1AC/500VA?

Proax is an authorized distributor of Phoenix Contact QUINT-UPS/ 1AC/ 1AC/500VA and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesQUINTUPS1AC1AC500VA
Pack Size1
Recommended

Available for order