Official Distributor
SKU
MPN
QUINT-UPS/ 1AC/ 1AC/500VA
Weight
2.51 kg
Series QUINT-UPS
QUINT-UPS/ 1AC/ 1AC/500VA - Uninterruptible power supply
Uninterruptible power supply with IQ technology 1AC/1AC/500 VA. For 120 V AC/230 V AC applications. Provides information regarding the charging state, remaining runtime, and service life of your rechargeable battery module at all times and thereby increases system availability.
- Optimum use of the buffer time and preventive monitoring of the energy storage
- Can be used worldwide
- Maximum efficiency
- Comprehensive signaling and parameterization
- Simplified startup
Technical Specifications
AC operation
Input Voltage | 240 V AC |
Input Voltage | 100 V AC |
Input Voltage | 120 V AC -20 % / +15 % |
Input Voltage | 230 V AC -20 % / +15 % |
Nominal input voltage range | 100 V AC ... 240 V AC |
Input voltage range | 184 V AC ... 264 V AC |
Input voltage range | 96 V AC ... 138 V AC |
Input voltage range | 96 V AC ... 264 V AC |
Input Voltage Range AC | 196 V AC ... 264 V AC |
Input Voltage Range AC | 102 V AC ... 138 V AC |
Input Voltage Range AC | 96 V AC ... 264 V AC |
Voltage type of supply voltage | AC |
Nominal frequency | 50 Hz ... 60 Hz |
Nominal frequency | 50 Hz ... 60 Hz |
AC frequency range | 45 Hz ... 65 Hz |
Buffer period | 1 h (38 AH) |
Current consumption | 2.2 A (230 V AC) |
Current consumption | 0.18 A (230 V AC) |
Current consumption | 0.8 A (230 V AC) |
Current consumption | 3.7 A (230 V AC) |
Current consumption | 4.3 A (120 V AC) |
Current consumption | 0.35 A (120 V AC) |
Current consumption | 1.3 A (120 V AC) |
Current consumption | 6.8 A (120 V AC) |
Fixed backup threshold | Configurable, 10% deviation from nominal input voltage set by default |
Variable connect threshold | Can be configured using UPS-CONF software |
Power factor (cos phi) | 0.8 |
Device mains fuse | 10 A |
Permissible backup fuse | B16 230 V AC |
Permissible backup fuse | 20 A 120 V AC, Listed breaker |
Digital Control Low-Active (configurable)
Battery-operated start 120 V AC Default | Plug-in bridge (output +24 V DC, 30 mA to input A1) |
Battery-operated start 230 V AC Default | Plug-in bridge (output +24 V DC, 30 mA to input A2) |
Output data
Classification according to IEC 62040-3 | VFD-SS-311 |
Efficiency | > 98 % (Mains operation) |
Efficiency | > 98 % (120 V AC) |
Efficiency | > 86 % (Battery operation) |
Nominal Output Voltage | 120 V AC |
Nominal Output Voltage | 230 V AC |
Output voltage range | 96 V AC ... 144 V AC |
Output voltage range | 184 V AC ... 264 V AC |
Form of output voltage | Pure sine |
Nominal output current (IN) | 4.3 A (120 V AC, -25 °C ... 50 °C) |
Nominal output current (IN) | 2.2 A (230 V AC, -25°C ... 40°C) |
Output current limit | 5.2 A (120 V AC) |
Output current limit | 2.7 A (230 V AC) |
POWER BOOST (IBoost) | 5.2 A (120 V AC, -25 °C ... 40 °C) |
POWER BOOST (IBoost) | 2.7 A (230 V AC, -25°C ... 40°C) |
Bridging time | 3600 s |
Derating | > 50 °C ... 70 °C (2.5 %/K) |
UPS connection in parallel | no |
UPS connection in series | no |
Output Power | 516 W |
Apparent power | 500 VA |
Nominal power | 400 W |
Crest factor | 2.8 |
Switch-over time | < 10 ms |
Connection in parallel | no |
Connection in series | No |
Mains operation
Nominal Output Voltage | 120 V AC |
Nominal Output Voltage | 230 V AC |
Output voltage range | 102 V AC ... 138 V AC |
Output voltage range | 196 V AC ... 264 V AC |
Nominal output current (IN) | 4.3 A (120 V AC) |
Nominal output current (IN) | 2.2 A (230 V AC) |
POWER BOOST (IBoost) | 5.2 A |
POWER BOOST (IBoost) | 2.7 A |
Permissible backup fuse | AC: 1 x circuit breaker - recommended fuse |
Battery operation
Nominal Output Voltage | 120 V AC |
Nominal Output Voltage | 230 V AC |
Nominal output current (IN) | 2.2 A (230 V AC) |
Nominal output current (IN) | 4.3 A (120 V AC) |
POWER BOOST (IBoost) | 2.7 A (230 V AC) |
POWER BOOST (IBoost) | 5.2 A (120 V AC) |
Permissible backup fuse | 25 A in parallel operation of 3.5 AH and 60 WH |
Permissible backup fuse | 50 A in parallel operation of 7.2 AH, 12 AH, and 38 AH |
Buffer period | 10 min. (400 W / 7,2 Ah) |
Signal: Alarm
Maximum Switching Voltage | ≤ 30 V DC |
Output Voltage | 24 V (SELV) |
Continuous load current | ≤ 30 mA |
Signal: Battery mode
Maximum Switching Voltage | ≤ 30 V DC |
Output Voltage | 24 V (SELV) |
Continuous load current | ≤ 30 mA |
Signal: POWER BOOST
Maximum Switching Voltage | ≤ 30 V DC |
Output Voltage | 24 V (SELV) |
Continuous load current | ≤ 30 mA |
Energy storage
Nominal voltage UN | 24 V DC |
End-of-charge voltage | 25 V DC ... 30 V DC (temperature compensated) |
Charging current | 2 A |
Nominal capacity range | 3.4 Ah ... 114 Ah (3x 38 Ah) |
Battery presence check/time interval | 1 min. |
Battery presence check (cyclic) | 60 s |
Energy storage device connection in parallel | yes, 3 (observe line protection) |
Energy storage device connection in series | no |
IQ Technology | Yes |
Temperature compensation | 42 mV/K (preset) |
Temperature compensation (preset) | -42 mV/K |
Permissible backup fuse | 50 A |
Network management | Yes |
Input
Connection Method | Screw connection |
Conductor cross section, rigid min. | 1.5 mm² |
Conductor cross section, rigid max. | 6 mm² |
Conductor cross section flexible min. | 1.5 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M4 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Output
Connection Method | Screw connection |
Conductor cross section, rigid min. | 1.5 mm² |
Conductor cross section, rigid max. | 6 mm² |
Conductor cross section flexible min. | 1.5 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M4 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Signal
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M4 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Interfaces
Interface | IFS (Interface system data port) |
Interface | MINI-USB type B |
Signaling
Types of signaling | LED |
Types of signaling | Active switching outputs |
Types of signaling | Interface/software |
Signal output: Status indicator 120 V AC
Signalization designation | AC mode of operation |
Status display | LED |
Note on status display | static on |
Signal output: Status indicator 230 V AC
Signalization designation | AC mode of operation |
Status display | LED |
Color | green |
Note on status display | static on |
Signal output: Transistor output, active
Signalization designation | Alarm |
Status display | LED |
Color | red |
Note on status display | static on |
Signalization designation | Battery mode |
Status display | LED |
Color | yellow |
Note on status display | static on |
Signalization designation | POWER BOOST |
Status display | LED |
Color | yellow |
Note on status display | static on |
Signal output
Signalization designation | Battery charge |
Status display | Bar graph |
Color | red/green |
Electrical properties
Insulation voltage input, output / housing | 1.5 kV AC |
Insulation voltage input, output / housing | 2.1 kV DC |
Product properties
Product family | QUINT AC-USV |
IQ Technology | Yes |
MTBF (IEC 61709, SN 29500) | > 240513 h (40 °C) |
Insulation characteristics
Protection class | I |
Life expectancy (electrolytic capacitors)
Time | 184982 h |
Dimensions
Width | 125 mm |
Height | 130 mm |
Depth | 125 mm |
Installation dimensions
Installation distance right/left | 5 mm / 5 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Mounting Position | horizontal DIN rail NS 35, EN 60715 |
Material specifications
Housing Material | Metal |
Housing Material | Steel sheet, zinc-plated |
Type of housing | Aluminum (AlMg3) |
Hood version | Galvanized sheet steel, free from chrome (VI) |
Side element version | Aluminum |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 50 °C Derating: 2.5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Ambient temperature (start-up type tested) | -40 °C |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (Operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
Vibration (Operation) | 15 Hz ... 150 Hz, 2.3g tv = 90 min. |
Standards and Regulations
Rail applications | EN 50121-4 |
Standards
Standard uninterruptible power supply systems | EN 62040-1 |
Uninterruptible power supply systems
Standard designation | Uninterruptible power supply systems |
Standards/specifications | EN 62040-1 |
UL
Identification | UL/C-UL Recognized UL 1778 |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Interference emission | Noise emission in accordance with EN 62040-2 |
Noise immunity | Immunity in accordance with EN 62040-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | 8 kV (Test Level 4) |
Discharge in air | 15 kV (Test Level 4) |
Comments | Criterion A |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 3 GHz |
Test field strength | 10 V/m |
Frequency Range | 1 GHz ... 3 GHz |
Test field strength | 10 V/m |
Frequency Range | 2 GHz ... 3 GHz |
Test field strength | 3 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) |
Comments | Criterion A |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 1 kV (Test Level 2 - symmetrical) |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 0.5 kV (Test Level 1 - symmetrical) |
Output | 0.5 kV (Test Level 1 - asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
I/O/S | asymmetrical |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Emitted interference
Radio interference voltage | EN 62040-2 (Class C1) |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Accessories
Why Proax for Phoenix Contact 2320270?
Proax is an authorized distributor of Phoenix Contact 2320270 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended