QUINT-UPS/ 24DC/ 24DC/10/3.4AH
This product is Not Cancellable/Not Returnable
Series QUINT-UPS

QUINT-UPS/ 24DC/ 24DC/10/3.4AH - Uninterruptible power supply

Uninterruptible power supply with IQ Technology and integrated battery for DIN rail mounting, input: 24 V DC, output: 24 V DC/10 A, battery: lead AGM 4 Ah, including mounted universal DIN rail adapter UTA 107/30

  • Easy handling thanks to automatic battery detection, tool-free battery replacement during operation, and communication via the IFS interface
  • Reliable starting of difficult loads with the static POWER BOOST power reserve with up to 1.5 times the nominal current permanently
  • Fast tripping of standard circuit breakers with SFB (selective fuse breaking) technology
  • Device suitable for universal use thanks to comprehensive license package and extensive parameterization and diagnostics options
Technical Specifications

General

Note on the batteryThis product contains a battery with a limited shelf life that must be charged every few months. The product packaging indicates when the battery must be started up or recharged. The general shelf life can be found in the technical data area under “Latest startup”.

DC operation

Input Voltage24 V DC
Input voltage range18 V DC ... 30 V DC
Input voltage range DC18 V DC ... 30 V DC
Voltage type of supply voltageDC
Buffer period180 min. (1 A)
Buffer period10 min. (10 A)
Current consumption18.6 A (24 V DC)
Current consumption9.5 mA
Current consumption3.6 A
Current consumption14 A

Output data

Efficiency> 97.6 % (Mains operation, with charged energy storage)
Efficiency96.41 %
Nominal Output Voltage24 V DC
Output voltage range18 V DC ... 30 V DC
Nominal output current (IN)10 A (0 °C ... 40 °C)
Output current limit> 15 A (Battery operation)
Bridging time600 s
Derating60 °C ... 70 °C (2.5 %/K)
Output Power240 W
Power dissipation3.1 W (Mains operation)
Power dissipation3.19 W (Mains operation)
Power dissipation1.8 W (Mains operation)
Power dissipation6.3 W (Battery operation)
Power dissipation4 W (Battery operation)
Power dissipation5.1 W (Battery operation)
Output fuse1x 25 A
Connection in parallel2
Connection in seriesNo

Mains operation

Nominal Output Voltage24 V DC
Output voltage range18 V DC ... 30 V DC (UOUT = UIN - 0,1 V DC)
Nominal output current (IN)10 A (0 °C ... 40 °C)
POWER BOOST (IBoost)15 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB)60 A (0 °C ... 40 °C)
Duration12 ms (SFB technology)

Battery operation

Nominal Output Voltage24 V DC
Output voltage range19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
Nominal output current (IN)10 A (0 °C ... 40 °C)
POWER BOOST (IBoost)15 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB)65 A (0 °C ... 40 °C)
Duration15 ms (SFB technology)

Signal: Alarm

Output descriptionRelay
Output Voltage≤ 30 V AC/DC
Continuous load current≤ 100 mA

Signal: Battery charge

Output descriptionRelay
Output Voltage≤ 30 V AC/DC
Continuous load current≤ 100 mA

Signal: Battery mode

Output descriptionRelay
Output Voltage≤ 30 V AC/DC
Continuous load current≤ 100 mA

Signal

Continuous load current≤ 200 mA

Energy storage

Nominal voltage UN24 V DC
End-of-charge voltage24 V DC ... 29 V DC (temperature compensated)
Charging current1.2 A
Nominal capacity4 Ah
Buffer period180 min. (1 A)
Buffer period10 min. (10 A)
Battery module service life6 Years ... 9 Years (20 °C)
Latest startup date (battery only)6 Months (0 °C ... 20 °C)
Latest startup (battery only) - range3 Months ... 6 Months (20 °C ... 30 °C)
Latest startup (battery only) - range1 Months ... 3 Months (30 °C ... 40 °C)
Battery technologyVRLA-AGM
Memory mediumVRLA-AGM Battery 4.0 Ah
Accumulator type2x BB Battery HR4.2-12FR (from UPS V/C-level 06)
IQ TechnologyYes
Temperature sensoryes
Network managementYes

Input

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.16
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM4
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Output

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.16
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM4
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signal

Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Screw threadM4
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Interfaces

InterfaceIFS (Interface system data port)

Signaling

Types of signalingLED
Types of signalingRelay contact
Types of signalingInterface/software

Signal output

Signalization designationPower In OK
Status displayLED
Note on status displaystatic on
Note on status displaystatic on

Signal output: Switching output

Signalization designationAlarm
Status displayLED
Note on status displaystatic on
Colorred
Note on status displaystatic on
Signalization designationBattery charge
Status displayLED bar graph
Note on status displaydynamic
Colorred/green
Note on status displaydynamic
Signalization designationBattery mode
Status displayLED
Note on status displaystatic on
Coloryellow
Note on status displaystatic on

Product properties

Product familyQUINT UPS ‒ UPS with integrated battery
DisposalUsed batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations.
IQ TechnologyYes
MTBF (IEC 61709, SN 29500)> 806000 h (40 °C)

Insulation characteristics

Protection classIII
Degree of pollution2

Life expectancy (electrolytic capacitors)

Time295585 h

Dimensions

Width120 mm
Height169 mm
Depth125 mm

Installation dimensions

Installation distance right/left5 mm / 5 mm
Installation distance top/bottom50 mm / 50 mm

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: horizontal 5 mm, vertical 50 mm
Mounting Positionhorizontal DIN rail NS 35, EN 60715

Material specifications

Housing MaterialMetal
Housing MaterialSteel sheet, zinc-plated
Type of housingSteel sheet, zinc-plated
Side element versionGalvanized sheet steel, closed

Ambient conditions

Degree of ProtectionIP20
Ambient temperature (storage/transport)-20 °C ... 40 °C
Ambient temperature (charge)0 °C ... 40 °C
Ambient temperature (discharge)-20 °C ... 50 °C
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Vibration (Operation)15 Hz ... 150 Hz, 2.3g tv = 90 min.

Standards and Regulations

Rail applicationsEN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard - Electrical safetyEN 61558-2-17

Approvals

UL approvalsUL/C-UL Recognized UL 60950-1
UL approvalsUL Listed UL 508

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength20 V/m
Frequency Range1 GHz ... 3 GHz
Test field strength10 V/m
Frequency Range2 GHz ... 3 GHz
Test field strength3 V/m
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input2 kV (Test Level 3 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input0.5 kV (Test Level 1 - symmetrical)
Input0.5 kV (Test Level 1 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Emitted interference

Standards/regulationsEN 61000-6-3
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Accessories

Why Proax for Phoenix Contact 2320267?

Proax is an authorized distributor of Phoenix Contact 2320267 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability