Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
NBC-M12MSD/ 2,0-93E/M12FSD
Weight
0.124 kg
This product is Not Cancellable/Not Returnable
Series NBC-M

NBC-M12MSD/ 2,0-93E/M12FSD - Network cable

Network cable, Ethernet CAT5 (100 Mbps), 4-position, PUR halogen-free, water blue RAL 5021, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Socket straight M12, coding: D / IP67, cable length: 2 m

Technical Specifications

Notes

GeneralFurther products with variable cable type and variable cable length can be found in the accessories section

Product properties

ApplicationStandard
Sensor TypeEthernet
Number of Positions4
No. of cable outlets1
Shieldedyes
CodingD

Insulation characteristics

Overvoltage categoryII
Degree of pollution3

Interfaces

Bus systemEthernet
Signal type/categoryEthernet CAT5 (IEC 11801), 100 Mbps

Signaling

Status displayNo
Status display presentNo

Electrical properties

Nominal voltage UN48 V AC
Nominal voltage UN60 V DC
Nominal current IN4 A
Transmission mediumCopper
Transmission characteristics (category)CAT5 (IEC 11801:2002)

Material specifications

Flammability rating according to UL 94V0

Connection 1

Dimensional drawingPin assignment M12 male connector, 4-pos., D-coded, male side
TypeM12 Pin, straight, 4-position, AST, Keying: D
Number of Positions4
Shieldedyes
Signal type/categoryEthernet CAT5 (IEC 11801), 100 Mbps
Insertion/withdrawal cycles≥ 100
Insulation resistance≥ 100 MΩ
Overvoltage categoryII
Degree of pollution3
Tightening torque0.4 Nm
Contact MaterialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated
Seal materialFKM
Flammability rating according to UL 94V0
Degree of ProtectionIP65
Degree of ProtectionIP67
Ambient Temperature (Operation)-25 °C ... 85 °C
Standard designationM12 connector
Standards/regulationsIEC 61076-2-101

Connection 2

Dimensional drawingPin assignment M12 socket, 4-pos., D-coded, female side
TypeM12 Socket, straight, 4-position, AST, Keying: D
Number of Positions4
Shieldedyes
Signal type/categoryEthernet CAT5 (IEC 11801), 100 Mbps
Insertion/withdrawal cycles≥ 100
Insulation resistance≥ 100 MΩ
Overvoltage categoryII
Degree of pollution3
Tightening torque0.4 Nm
Contact MaterialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated
Seal materialFKM
Flammability rating according to UL 94V0
Degree of ProtectionIP65
Degree of ProtectionIP67
Ambient Temperature (Operation)-25 °C ... 85 °C
Standard designationM12 connector
Standards/regulationsIEC 61076-2-101

Cable/line

Cable Length2 m

Ethernet flexible CAT5, 2-pair [93E]

Cable weight42 kg/km
UL AWM style20963 (80°C/30 V)
Wiring standards/regulationsElectrical requirements EN 50288-2-2
Number of Positions4
Shieldedyes
Cable TypeEthernet flexible CAT5, 2-pair [93E]
Conductor structure2x2xAWG26/7, SF/UTP
Signal runtime5.3 ns/m
Conductor structure signal line7x 0.16 mm
AWG Signal Line26
Conductor Cross Section2x 2x 0.14 mm²
Wire diameter incl. insulation0.98 mm
External Cable Diameter6.40 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorwater blue RAL 5021
Conductor materialBare Cu litz wires
Material wire insulationFoamed PE
Single wire, colorwhite/orange-orange, white/green-green
Thickness, outer sheath1.20 mm
Twisted pairs2 cores to the pair
Overall twistTwo pairs with two fillers to the core
Optical shield covering70 %
Insulation resistance≥ 500 MΩ*km
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Loop resistance≤ 290.00 Ω/km
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Cable capacityapprox. 45 nF/km (at 1 kHz)
Nominal voltage, cable≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Current carrying capacity of cable2.00 A (according to DIN VDE 0891-1)
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Smallest bending radius, fixed installation26 mm
Smallest bending radius, movable installation52 mm
Tensile strength≤ 80 N
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)56.3 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)50.3 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)47.2 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)45.8 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)42.9 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)38.4 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)53.3 dB (at 4 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)47.3 dB (at 10 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)44.2 dB (at 16 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)42.8 dB (at 20 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)39.9 dB (at 31.25 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)35.4 dB (at 62.5 МHz)
Power-summated near end crosstalk attenuation (PSNEXT)32.3 dB (at 100 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
Return attenuation (RL)24.1 dB (at 8 МHz)
Return attenuation (RL)25 dB (at 10 MHz)
Return attenuation (RL)25 dB (at 16 MHz)
Return attenuation (RL)25 dB (at 20 МHz)
Return attenuation (RL)23.6 dB (at 31.25 МHz)
Return attenuation (RL)21.5 dB (at 62.5 МHz)
Return attenuation (RL)20.1 dB (at 100 MHz)
Shield attenuation3.2 dB (with 1 MHz)
Shield attenuation6 dB (at 4 МHz)
Shield attenuation9.5 dB (at 10 MHz)
Shield attenuation12.1 dB (at 16 MHz)
Shield attenuation13.6 dB (at 20 МHz)
Shield attenuation17.1 dB (at 31.25 МHz)
Shield attenuation24.8 dB (at 62.5 МHz)
Shield attenuation32 dB (at 100 MHz)
Halogen-freeaccording to IEC 60754-1
Flame resistanceaccording to IEC 60332-1-2
Flame resistancein acc. to UL VW1
Flame resistancein accordance with UN ECE-R 118.03
Resistance to Oilin accordance with EN 60811-2-1
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-20 °C ... 80 °C (Cable, flexible installation)
Ambient temperature (installation)-20 °C ... 80 °C

Ambient conditions

Degree of ProtectionIP65
Degree of ProtectionIP67

M12

Standard designationM12 connector
Standards/specificationsIEC 61076-2-101
Accessories

Why Proax for Phoenix Contact 1407401?

Proax is an authorized distributor of Phoenix Contact 1407401 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability