Official Distributor
SKU
MPN
NBC-M12MSD/ 2,0-93E/R4AC
Weight
0.116 kg
This product is Not Cancellable/Not Returnable
Series NBC-M
NBC-M12MSD/ 2,0-93E/R4AC - Network cable
Network cable, Ethernet CAT5 (100 Mbps), 4-position, PUR halogen-free, water blue RAL 5021, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Plug straight RJ45 / IP20, cable length: 2 m
Technical Specifications
Notes
General | Further products with variable cable type and variable cable length can be found in the accessories section |
Product properties
Application | Standard |
Sensor Type | Ethernet |
Number of Positions | 4 |
Shielded | yes |
Insulation characteristics
Overvoltage category | I |
Degree of pollution | 2 |
Interfaces
Bus system | Ethernet |
Signal type/category | Ethernet CAT5 (IEC 11801), 100 Mbps |
Signaling
Status display | No |
Status display present | No |
Electrical properties
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 1 A |
Transmission medium | Copper |
Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
Material specifications
Flammability rating according to UL 94 | V2 |
Connection 1
Dimensional drawing | Pin assignment M12 male connector, 4-pos., D-coded, male side |
Type | M12 Pin, straight, 4-position, AST, Keying: D |
Number of Positions | 4 |
Shielded | yes |
Signal type/category | Ethernet CAT5 (IEC 11801), 100 Mbps |
Insertion/withdrawal cycles | ≥ 100 |
Insulation resistance | ≥ 100 MΩ |
Overvoltage category | II |
Degree of pollution | 3 |
Tightening torque | 0.4 Nm |
Contact Material | CuSn |
Contact surface material | Ni/Au |
Contact carrier material | PA 6.6 |
Material for screw connection | Zinc die-cast, nickel-plated |
Seal material | FKM |
Flammability rating according to UL 94 | V0 |
Degree of Protection | IP65 |
Degree of Protection | IP67 |
Ambient Temperature (Operation) | -25 °C ... 85 °C |
Standard designation | M12 connector |
Standards/regulations | IEC 61076-2-101 |
Connection 2
Dimensional drawing | Connector pin assignment plug RJ45 |
Type | RJ45 Pin, straight |
Signal type/category | Ethernet CAT5 (IEC 11801), 100 Mbps |
Insertion/withdrawal cycles | ≥ 750 |
Insulation resistance | ≥ 100 MΩ |
Overvoltage category | I |
Degree of pollution | 2 |
Contact Material | CuSn |
Contact surface material | Ni/Au |
Contact carrier material | PC |
Flammability rating according to UL 94 | V2 |
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Cable/line
Cable Length | 2 m |
Ethernet flexible CAT5, 2-pair [93E]
Cable weight | 42 kg/km |
UL AWM style | 20963 (80°C/30 V) |
Wiring standards/regulations | Electrical requirements EN 50288-2-2 |
Number of Positions | 4 |
Shielded | yes |
Cable Type | Ethernet flexible CAT5, 2-pair [93E] |
Conductor structure | 2x2xAWG26/7, SF/UTP |
Signal runtime | 5.3 ns/m |
Conductor structure signal line | 7x 0.16 mm |
AWG Signal Line | 26 |
Conductor Cross Section | 2x 2x 0.14 mm² |
Wire diameter incl. insulation | 0.98 mm |
External Cable Diameter | 6.40 mm ±0.2 mm |
Outer sheath, material | PUR |
External sheath, color | water blue RAL 5021 |
Conductor material | Bare Cu litz wires |
Material wire insulation | Foamed PE |
Single wire, color | white/orange-orange, white/green-green |
Thickness, outer sheath | 1.20 mm |
Twisted pairs | 2 cores to the pair |
Overall twist | Two pairs with two fillers to the core |
Optical shield covering | 70 % |
Insulation resistance | ≥ 500 MΩ*km |
Coupling resistance | ≤ 100.00 mΩ/m (at 10 MHz) |
Loop resistance | ≤ 290.00 Ω/km |
Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
Cable capacity | approx. 45 nF/km (at 1 kHz) |
Nominal voltage, cable | ≤ 100 V (Peak value, not for high-power applications) |
Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
Test voltage Core/Shield | 700.00 V (50 Hz, 1 min.) |
Current carrying capacity of cable | 2.00 A (according to DIN VDE 0891-1) |
Minimum bending radius, fixed installation | 4 x D |
Minimum bending radius, flexible installation | 8 x D |
Smallest bending radius, fixed installation | 26 mm |
Smallest bending radius, movable installation | 52 mm |
Tensile strength | ≤ 80 N |
Near end crosstalk attenuation (NEXT) | 65.3 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 56.3 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 50.3 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 47.2 dB (at 16 MHz) |
Near end crosstalk attenuation (NEXT) | 45.8 dB (at 20 МHz) |
Near end crosstalk attenuation (NEXT) | 42.9 dB (at 31.25 МHz) |
Near end crosstalk attenuation (NEXT) | 38.4 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 35.3 dB (at 100 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 62.3 dB (with 1 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 53.3 dB (at 4 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 47.3 dB (at 10 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 44.2 dB (at 16 MHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 42.8 dB (at 20 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 39.9 dB (at 31.25 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 35.4 dB (at 62.5 МHz) |
Power-summated near end crosstalk attenuation (PSNEXT) | 32.3 dB (at 100 MHz) |
Return attenuation (RL) | 23 dB (at 4 МHz) |
Return attenuation (RL) | 24.1 dB (at 8 МHz) |
Return attenuation (RL) | 25 dB (at 10 MHz) |
Return attenuation (RL) | 25 dB (at 16 MHz) |
Return attenuation (RL) | 25 dB (at 20 МHz) |
Return attenuation (RL) | 23.6 dB (at 31.25 МHz) |
Return attenuation (RL) | 21.5 dB (at 62.5 МHz) |
Return attenuation (RL) | 20.1 dB (at 100 MHz) |
Shield attenuation | 3.2 dB (with 1 MHz) |
Shield attenuation | 6 dB (at 4 МHz) |
Shield attenuation | 9.5 dB (at 10 MHz) |
Shield attenuation | 12.1 dB (at 16 MHz) |
Shield attenuation | 13.6 dB (at 20 МHz) |
Shield attenuation | 17.1 dB (at 31.25 МHz) |
Shield attenuation | 24.8 dB (at 62.5 МHz) |
Shield attenuation | 32 dB (at 100 MHz) |
Halogen-free | according to IEC 60754-1 |
Flame resistance | according to IEC 60332-1-2 |
Flame resistance | in acc. to UL VW1 |
Flame resistance | in accordance with UN ECE-R 118.03 |
Resistance to Oil | in accordance with EN 60811-2-1 |
Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -20 °C ... 80 °C (Cable, flexible installation) |
Ambient temperature (installation) | -20 °C ... 80 °C |
Ambient conditions
Degree of Protection | IP65 (M12 connector) |
Degree of Protection | IP67 (M12 connector) |
Degree of Protection | IP20 (RJ45 connector) |
M12
Standard designation | M12 connector |
Standards/specifications | IEC 61076-2-101 |
Accessories
Why Proax for Phoenix Contact 1407361?
Proax is an authorized distributor of Phoenix Contact 1407361 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 1038762 - Network cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position, PUR/FRNC halogen-free, green RAL 6018, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Socket straight M12, coding: D / IP67, cable length: 2 m
- 1038738 - Network cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position, PUR/FRNC halogen-free, green RAL 6018, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Plug straight M12, coding: D / IP67, cable length: 2 m
- 1416200 - Network cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position, PUR/FRNC halogen-free, green RAL 6018, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Plug straight M12, coding: D / IP67, cable length: 2 m
- 1038732 - Network cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position, PUR/FRNC halogen-free, green RAL 6018, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Plug straight RJ45 / IP20, cable length: 2 m
- 1416188 - Network cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position, PUR/FRNC halogen-free, green RAL 6018, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Plug straight RJ45 / IP20, cable length: 2 m
- 1407554 - Network cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position, PVC/PVC, green RAL 6018, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Socket straight M12, coding: D / IP67, cable length: 2 m
- 1407525 - Network cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position, PVC/PVC, green RAL 6018, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Plug straight M12, coding: D / IP67, cable length: 2 m
- 1524378 - Network cable, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position, PVC/PVC, green RAL 6018, shielded (Aluminum-coated foil, tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: D / IP67, on Plug straight M12, coding: D / IP67, cable length: 2 m