Proax
fr0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
PHX1404397
MPN
1404397
Weight
0.159 kg

NBC-M12MSD/ 2,0-93C/R4AQ WL - Network cable

Assembled PROFINET cable, CAT5e, shielded, star quad, AWG 22 flexible cable conduit capable (7-wire), RAL 6018 (yellow-green), M12 plug on RJ45 plug/IP20, line, length 2 m

Technical Specifications

Product properties

Number of Positions4
No. of cable outlets1
Shieldedyes

Insulation characteristics

Overvoltage categoryI
Degree of pollution3

Electrical properties

Nominal voltage UN48 V AC
Transmission characteristics (category)CAT5 (IEC 11801:2002)

Mechanical data

Insertion/withdrawal cycles≥ 100

Material specifications

Flammability rating according to UL 94V0

Connection 1

TypePlug straight M12

Connection 2

Typefree cable end

Cable/line

Cable Length2 m

PROFINET drag chain CAT5 [93C]

Cable weight61 kg/km
Number of Positions4
Shieldedyes
Cable TypePROFINET drag chain CAT5 [93C]
Conductor structure1x4xAWG22/7, SF/TQ
Signal runtime5.3 ns/m
Signal speed0.66 c
Conductor structure signal line7x 0.25 mm
AWG Signal Line22
Conductor Cross Section4x 0.34 mm²
Wire diameter incl. insulation1.5 mm
External Cable Diameter6.50 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorgreen RAL 6018
Conductor materialTin-plated Cu litz wires
Material wire insulationPE
Single wire, colorwhite, yellow, blue, orange
Thickness, outer sheathapprox. 0.90 mm
Overall twistStar quad
Optical shield covering85 %
Insulation resistance≥ 500 MΩ*km
Coupling resistance≤ 20.00 mΩ/m (at 10 MHz)
Loop resistance≤ 120.00 Ω/km
Wave impedance100 Ω ±15 Ω (at 1 ... 100 MHz)
Nominal voltage, cable600 V (UL rating)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000.00 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation7.5 x D
Smallest bending radius, fixed installation33 mm
Smallest bending radius, movable installation49 mm
Max. bending cycles3000000
Tensile strength≤ 150 N
Torsion force± 30 °/m
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)76 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)70 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)65 dB (at 16 MHz)
Near end crosstalk attenuation (NEXT)63 dB (at 20 МHz)
Near end crosstalk attenuation (NEXT)60 dB (at 31.25 МHz)
Near end crosstalk attenuation (NEXT)55 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)50 dB (at 100 MHz)
Shield attenuation2.1 dB (with 1 MHz)
Shield attenuation4 dB (at 4 МHz)
Shield attenuation6.3 dB (at 10 MHz)
Shield attenuation8 dB (at 16 MHz)
Shield attenuation9 dB (at 20 МHz)
Shield attenuation11.4 dB (at 31.25 МHz)
Shield attenuation16.5 dB (at 62.5 МHz)
Shield attenuation21.3 dB (at 100 MHz)
Halogen-freeyes
Flame resistanceaccording to IEC 60332-1-2
Resistance to Oilin accordance with DIN EN 60811-2-1
Other resistanceUV resistant
Special PropertiesElectrical properties in accordance with EN 50288-2-2
Ambient Temperature (Operation)-40 °C ... 70 °C (cable, fixed installation)
Ambient Temperature (Operation)-40 °C ... 70 °C (Cable, flexible installation)
Ambient temperature (installation)-20 °C ... 60 °C

Ambient conditions

Ambient Temperature (Operation)-10 °C ... 60 °C (cable, fixed installation)
Ambient Temperature (Operation)-10 °C ... 60 °C (Cable, flexible installation)

Why Proax for Phoenix Contact NBC-M12MSD/ 2,0-93C/R4AQ WL?

Proax is an authorized distributor of Phoenix Contact NBC-M12MSD/ 2,0-93C/R4AQ WL and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Recommended

Available for order