MS132-20K

By ABB

ABBMS13220K
Weight 1 kg
ABBOfficial Distributor
The MS132-20K manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 20.0 A with Push-in spring terminals. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The MS132-K manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The MS132-K manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Height112 mm
Product Net Depth / Length87 mm
Product Net Weight0.317 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA, (250 V DC) 3 Poles in Series 10 kA, (400 V AC) 100 kA, (440 V AC) 30 kA, (500 V AC) 20 kA, (690 V AC) 3 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA, (400 V AC) 100 kA, (440 V AC) 30 kA, (500 V AC) 20 kA, (690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)300 A
Setting range16 ... 20 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 7.5 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 7.5 kW
Rated Operational VoltageMain Circuit 690 V AC, Main Circuit 250 V DC
Rated Operational Current (Ie)20 A
Rated Operational Current AC-3 (Ie)20 A
Rated Operational Current AC-3e (Ie)20 A
Rated Operational Current DC-5 (Ie)20 A
Rated Frequency (f)Main Circuit 50 Hz, Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 1.5 ... 2.3 W
Number of Poles3
Conventional Free-air Thermal Current (Ith)Main Circuit 20 A
Degree of ProtectionHousing IP20, Main Circuit Terminals IP20
Pollution degree3
Electrical Durability50000 cycle
Mechanical Durability100000 cycle
Terminal TypePush-in Spring Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.5 ... 4 mm², Flexible with Insulated Ferrule 1x 0.5 ... 4 mm², Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm², Flexible 1/2x 0.75 ... 4 mm², Solid 1/2x 1 ... 2.5 mm², Stranded 1/2x 1 ... 6 mm²
Wire Stripping LengthMain Circuit 12 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm, Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm, Electrical Conductive Board, Vertical 75 mm, Other Device Same Type, Horizontal 0 mm, Other Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsIEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1
RemarksUL508 Self-Protected Combination Motor Controller (Type E) in combination with terminal spacer TS1-M3-K

Technical UL/CSA

Short-circuit current rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 18 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA, Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA, Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 5 Hp, (208 V AC) Three Phase 5 Hp, (220 ... 240 V AC) Three Phase 5 Hp, (440 ... 480 V AC) Three Phase 10 Hp, (550 ... 600 V AC) Three Phase 15 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 17.5 A, (208 V AC) Three Phase 16.7 A, (220 ... 240 V AC) Three Phase 15.2 A, (440 ... 480 V AC) Three Phase 14 A, (550 ... 600 V AC) Three Phase 17 A
Locked Rotor Amps(200 V AC) Three Phase 105.8 A, (208 V AC) Three Phase 102 A, (220 ... 240 V AC) Three Phase 92 A, (440 ... 480 V AC) Three Phase 81 A, (550 ... 600 V AC) Three Phase 93 A
General Use Rating UL/CSA(600 V AC) 20 A
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 18-10 AWG, Stranded 1x 8 AWG

Environmental

Ambient Air TemperatureAround the Enclosure 0 ... +40 °C, Operation -25 ... +70 °C, Operation Compensated -25 ... +60 °C, Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-65g / 3 ... 150 Hz
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Why Proax for ABB MS132-20K?

Proax is an authorized distributor of ABB MS132-20K and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Recommended

Available for order