The MS132-25K manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 25.0 A with Push-in spring terminals. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The MS132-K manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The MS132-K manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips and terminal spacers are available as accessory.
Technical Specifications
Dimensions
Product Net Width | 45 mm |
Product Net Height | 112 mm |
Product Net Depth / Length | 87 mm |
Product Net Weight | 0.316 kg |
Technical
Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 50 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (250 V DC) 3 Poles in Series 10 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (400 V AC) 50 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (440 V AC) 30 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (500 V AC) 10 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (690 V AC) 3 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 50 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (440 V AC) 30 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (500 V AC) 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (690 V AC) 3 kA |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 375 A |
Setting range | 20 ... 25 A |
Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 11 kW |
Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 11 kW |
Rated Operational Voltage | Main Circuit 690 V AC |
Rated Operational Voltage | Main Circuit 250 V DC |
Rated Operational Current (Ie) | 25 A |
Rated Operational Current AC-3 (Ie) | 25 A |
Rated Operational Current AC-3e (Ie) | 25 A |
Rated Operational Current DC-5 (Ie) | 25 A |
Rated Frequency (f) | Main Circuit 50 Hz |
Rated Frequency (f) | Main Circuit 60 Hz |
Operating Frequency (fsw) | 0 ... 400 Hz |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
Rated Insulation Voltage (Ui) | 690 V |
Power Loss | at Rated Operating Conditions per Pole 1.8 ... 2.8 W |
Number of Poles | 3 |
Conventional Free-air Thermal Current (Ith) | Main Circuit 25 A |
Degree of Protection | Housing IP20 |
Degree of Protection | Main Circuit Terminals IP20 |
Pollution degree | 3 |
Electrical Durability | 50000 cycle |
Mechanical Durability | 100000 cycle |
Terminal Type | Push-in Spring Terminals |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.5 ... 4 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1x 0.5 ... 4 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm² |
Connecting Capacity Main Circuit | Flexible 1/2x 0.75 ... 4 mm² |
Connecting Capacity Main Circuit | Solid 1/2x 1 ... 2.5 mm² |
Connecting Capacity Main Circuit | Stranded 1/2x 1 ... 6 mm² |
Wire Stripping Length | Main Circuit 12 mm |
Recommended Screw Driver | Pozidriv 2 |
Mounting Position | 1 ... 6 |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm |
Minimum Mounting Distance | Electrical Conductive Board, Vertical 75 mm |
Minimum Mounting Distance | Other Device Same Type, Horizontal 0 mm |
Minimum Mounting Distance | Other Device Same Type, Vertical 150 mm |
Actuator Type | Rotary Handle |
Contact Position Indication | ON / OFF / TRIP |
Standards | IEC/EN 60947-1 |
Standards | IEC/EN 60947-2 |
Standards | IEC/EN 60947-4-1 |
Standards | UL 60947-1 |
Standards | UL 60947-4-1 |
Remarks | UL508 Self-Protected Combination Motor Controller (Type E) in combination with terminal spacer TS1-M3-K |
Technical UL/CSA
Short-circuit current rating (SCCR) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 18 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA |
Maximum Operating Voltage UL/CSA | Auxiliary Circuit 250 V AC/DC |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Horsepower Rating UL/CSA | (200 V AC) Three Phase 5 Hp |
Horsepower Rating UL/CSA | (208 V AC) Three Phase 7.5 Hp |
Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 7.5 Hp |
Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 15 Hp |
Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 20 Hp |
Full Load Amps Motor Use | (200 V AC) Three Phase 17.5 A |
Full Load Amps Motor Use | (208 V AC) Three Phase 24.2 A |
Full Load Amps Motor Use | (220 ... 240 V AC) Three Phase 22 A |
Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 21 A |
Full Load Amps Motor Use | (550 ... 600 V AC) Three Phase 22 A |
Locked Rotor Amps | (200 V AC) Three Phase 105.8 A |
Locked Rotor Amps | (208 V AC) Three Phase 140 A |
Locked Rotor Amps | (220 ... 240 V AC) Three Phase 127 A |
Locked Rotor Amps | (440 ... 480 V AC) Three Phase 116 A |
Locked Rotor Amps | (550 ... 600 V AC) Three Phase 116 A |
General Use Rating UL/CSA | (600 V AC) 25 A |
Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 18-10 AWG |
Connecting Capacity Main Circuit UL/CSA | Stranded 1x 8 AWG |
Why Proax for ABB MS132-25K?
Proax is an authorized distributor of ABB MS132-25K and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience