MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds.
They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.
This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit
tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism
and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and
single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts,
signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These
are suitable throughout the MS132-B/MS165-B range.
– designed in accordance to the applicable parts of IEC 60077 standard
– shocks and vibration withstand conforming to IEC 61373 (category 1, class B)
– usable according to European fire and smoke safety standard EN 45545-2
Technical Specifications
Dimensions
Product Net Width | 45 mm |
Product Net Height | 97.8 mm |
Product Net Depth / Length | 86.55 mm |
Product Net Weight | 0.31 kg |
Technical
Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 50 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (250 V DC) 3 Poles in Series 10 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (400 V AC) 50 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (440 V AC) 30 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (500 V AC) 10 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (690 V AC) 3 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 50 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (440 V AC) 30 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (500 V AC) 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (690 V AC) 3 kA |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 375 A |
Setting range | 20 ... 25 A |
Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 11 kW |
Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 11 kW |
Rated Operational Voltage | Main Circuit 690 V AC |
Rated Operational Voltage | Main Circuit 250 V DC |
Rated Operational Current (Ie) | 25 A |
Rated Operational Current AC-3 (Ie) | 25 A |
Rated Operational Current AC-3e (Ie) | 25 A |
Rated Operational Current DC-5 (Ie) | 25 A |
Rated Frequency (f) | Main Circuit 50 Hz |
Rated Frequency (f) | Main Circuit 60 Hz |
Operating Frequency (fsw) | 0 ... 400 Hz |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
Rated Insulation Voltage (Ui) | 690 V |
Power Loss | at Rated Operating Conditions per Pole 1.8 ... 2.8 W |
Number of Poles | 3 |
Conventional Free-air Thermal Current (Ith) | Main Circuit 25 A |
Degree of Protection | Housing IP20 |
Degree of Protection | Main Circuit Terminals IP10 |
Pollution degree | 3 |
Electrical Durability | 50000 cycle |
Mechanical Durability | 100000 cycle |
Terminal Type | Screw Terminals |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm² |
Connecting Capacity Main Circuit | Flexible 1/2x 1 ... 2.5 mm² |
Connecting Capacity Main Circuit | Flexible 1/2x 2.5 ... 6 mm² |
Connecting Capacity Main Circuit | Rigid 1/2x 1 ... 2.5 mm² |
Connecting Capacity Main Circuit | Rigid 1/2x 2.5 ... 6 mm² |
Tightening torque | Main Circuit 2 N·m |
Wire Stripping Length | Main Circuit 10 mm |
Recommended Screw Driver | Pozidriv 2 |
Mounting Position | 1 ... 6 |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm |
Minimum Mounting Distance | Electrical Conductive Board, Vertical 75 mm |
Minimum Mounting Distance | Other Device Same Type, Horizontal 0 mm |
Minimum Mounting Distance | Other Device Same Type, Vertical 150 mm |
Actuator Type | Rotary Handle |
Contact Position Indication | ON / OFF / TRIP |
Standards | IEC 60077-1 (applicable parts) |
Standards | IEC 60077-2 (applicable parts) |
Standards | IEC/EN 60947-1 |
Standards | IEC/EN 60947-2 |
Standards | IEC/EN 60947-4-1 |
Remarks | UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx |
Technical UL/CSA
Short-circuit current rating (SCCR) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA |
Short-circuit current rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Horsepower Rating UL/CSA | (200 V AC) Three Phase 5 Hp |
Horsepower Rating UL/CSA | (208 V AC) Three Phase 7.5 Hp |
Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 7.5 Hp |
Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 15 Hp |
Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 20 Hp |
Full Load Amps Motor Use | (200 V AC) Three Phase 17.5 A |
Full Load Amps Motor Use | (208 V AC) Three Phase 24.2 A |
Full Load Amps Motor Use | (220 ... 240 V AC) Three Phase 22 A |
Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 21 A |
Full Load Amps Motor Use | (550 ... 600 V AC) Three Phase 22 A |
Locked Rotor Amps | (200 V AC) Three Phase 105.8 A |
Locked Rotor Amps | (208 V AC) Three Phase 140 A |
Locked Rotor Amps | (220 ... 240 V AC) Three Phase 127 A |
Locked Rotor Amps | (440 ... 480 V AC) Three Phase 116 A |
Locked Rotor Amps | (550 ... 600 V AC) Three Phase 116 A |
General Use Rating UL/CSA | (600 V AC) 25 A |
Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-8 AWG |
Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 16-8 AWG |
Tightening Torque UL/CSA | Main Circuit 18 in·lb |
Why Proax for ABB MS132-25B?
Proax is an authorized distributor of ABB MS132-25B and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | MS13225B |
Pack Size | 1 |
Recommended