
2902005
SKU
PHX2902005
MPN
MINI MCR-2-NAM-2RO-PT
Series MINI-MCR
MINI MCR-2-NAM-2RO-PT - Isolation amplifier
Configurable NAMUR signal conditioner with plug-in connection technology for proximity sensors, floating switch contacts, and switch contacts with resistance circuit. 2 transistor outputs. Configurable via DIP switch. Push-in connection technology.
- Floating contacts and contacts with resistance circuit can be connected
- Power supply possible via the foot element (TBUS)
- Highly compact isolation amplifier for electrical isolation, amplification, and duplication of proximity sensor signals
- For proximity sensors according to IEC 60947-5-6 and EN 50227
- Second output can be used as a duplicator or error signaling output
- Error indication via diagnostic LED and analog signal
- N/O contacts at output
- Input and output signals can be configured via DIP switches
- 3-way isolation
Technical Specifications
Utilization restriction
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Product properties
| Product family | MINI Analog Pro |
| No. of channels | 1 |
| Configuration | DIP switches |
Insulation characteristics: GB Standard
| Overvoltage category | II |
| Pollution degree | 2 |
Functionality
| Configuration | DIP switches |
Electrical properties
| Electrical isolation | 4-way isolation |
| Electrical isolation between input and output | yes |
| Maximum power dissipation for nominal condition | 450 mW |
Electrical isolation Input/output/power supply
| Rated Insulation Voltage | 300 Vrms |
| Test voltage | 3 kV AC (50 Hz, 60 s) |
| Insulation | Reinforced insulation according to IEC/EN 61010-1 |
Supply
| Nominal Supply Voltage | 24 V DC |
| Supply Voltage Range | 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) |
| Typical current consumption | 18 mA (24 V DC) |
| Typical current consumption | 35 mA (12 V DC) |
| Power consumption | 450 mW (9.6 V DC) |
Signal: NAMUR
| Number of Inputs | 1 |
| Available Input Sources | NAMUR proximity sensors (IEC/EN 60947-5-6) |
| Available Input Sources | Floating switch contacts |
| Available Input Sources | Switch contacts with resistance circuit |
| Switching threshold "0" signal current | < 1.2 mA (blocking) |
| Switching threshold "1" signal, current | > 2.1 mA (conductive) |
| Line fault detection | > 6 mA (Short circuit) |
| Line fault detection | < 0.35 mA (Line break) |
| Line fault detection | Activated /deactivated via DIP switch |
| Non-load voltage | 8.2 V DC ±10 % |
Switching: Transistor
| Output description | Output 1: Signal output; Output 2: Fault signaling output or signal duplicator, can be set via DIP switches |
| Contact switching type | 2 N/O contacts |
| Maximum Switching Voltage | 30 V DC |
| Maximum Inrush Current | 50 mA |
| Min. switching current | 5 mA |
| Typical response time | 10 µs |
| Typical turn-off time | 35 µs |
| Switching frequency | 5 kHz |
Connection data
| Connection Method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² (with ferrule) |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² (without ferrule) |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 (flexible) |
Ex data
| Ex installation (EPL) | Gc |
| Ex installation (EPL) | Div. 2 |
Data: NFC interface
| No. of channels | 0 |
Signaling
| Status display | Green LED (supply voltage) |
| Status display | Yellow LED (switching output) |
| Error indication | Red LED |
Dimensions
| Width | 6.2 mm |
| Height | 109.81 mm |
| Depth | 119.2 mm |
Material specifications
| Color | gray (RAL 7042) |
| Housing Material | PBT |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Ambient conditions
| Degree of Protection | IP20 (not assessed by UL) |
| Ambient Temperature (Operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
| Certificate | CE-compliant |
ATEX
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | BVS 20 ATEX E 014X |
UKCA Ex (UKEX)
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | PxCIF21UKEX2902004X |
IECEx
| Identification | Ex ec IIC T4 Gc |
| Certificate | IECEx BVS 20.0010X |
CCC / China-Ex
| Identification | Ex nA IIC T4 Gc |
| Certificate | NEPSI GYJ20.1320X |
UL, USA/Canada
| Identification | UL 508 Listed |
| Identification | Class I, Div. 2, Groups A, B, C, D T6 |
| Identification | Class I, Zone 2, Group IIC T6 |
Shipbuilding approval
| Certificate | DNV GL TAA000021E Rev. 1 |
EAC Ex
| Identification | 2Ex ec IIC T4 Gc |
| Certificate | BY/112 02.01 TP012 103.01 00081 |
DNV GL data
| Temperature | B |
| Humidity | B |
| Vibration | A |
| EMC | A |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
| Noise immunity | EN 61000-6-2 |
| Note | When being exposed to interference, there may be minimal deviations. |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise emission | EN 61000-6-4 |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Comments | Safety measures must be taken to prevent electrostatic discharge. |
Electromagnetic HF field
| Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 |
Fast transients (burst)
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
Surge current load (surge)
| Standards/regulations | EN 61000-4-5 |
Conducted interference
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
Standards and Regulations
| Electrical isolation | 4-way isolation |
GB Standard
| Standards/regulations | GB 3836.1 |
| Standards/regulations | GB 3836.8 |
Mounting
| Mounting Type | DIN rail mounting |
| Assembly instructions | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. |
| Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2902005?
Proax is an authorized distributor of Phoenix Contact 2902005 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended



















