1105556
SKU
PHX1105556
MPN
TRIO-UPS-2G/1AC/24DC/20
Weight
2.004 kg
This product is Not Cancellable/Not Returnable
Series TRIO-UPS
TRIO-UPS-2G/1AC/24DC/20 - Uninterruptible power supply
TRIO UPS - UPS with integrated power supply, USB (Modbus/RTU), DIN rail mounting, Push-in connection, input: 1-phase, output: 24 V DC / 20 A
- Space saving: Combination of UPS module and power supply in the same housing
- Long buffer times, thanks to large selection of VRLA energy storage systems
- USB interface for connection to higher-level controllers such as industrial PCs
- Startup from the energy storage system possible, even without mains input
- Universal range of possible applications, thanks to a comprehensive package of approvals and an extended temperature range
- Easy installation, thanks to push-in connection technology
Documents
Technical Specifications
Input data
| Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
| Voltage type of supply voltage | AC |
| Inrush Current | < 10 A |
| Inrush current integral (I2t) | < 0.4 A2s |
| Frequency range (fN) | 50 Hz ... 60 Hz (±10 %) |
| Mains buffering time | ≥ 20 ms (120 V AC) |
| Switch-on time | typ. 200 ms |
| Typical current consumption | 6.4 A (100 V AC) |
| Input fuse | 10 A (slow-blow, internal) |
Signal Bat.-Start
| Connection labeling | 3.6 |
| Signalization designation | Bat.-Start |
| Low signal | Connection to SGnd with < 2.7 kΩ |
| High signal | Open (> 200 kΩ between Bat.-Start and SGnd) |
Signal Remote
| Connection labeling | 3.5 |
| Signalization designation | Remote |
| Low signal | Connection to SGnd with < 2.7 kΩ |
| High signal | Open (> 35 kΩ between Remote and SGnd) |
Output data
| Efficiency | typ. 88 % (100 V AC) |
| Efficiency | typ. 92 % (240 V AC) |
| Efficiency | typ. (Battery operation) |
| Derating | > 60 °C (2.5%/K of POut nom.) |
| Crest factor | 1.57 (120 V AC) |
| Crest factor | 1.58 (230 V AC) |
| Switch-over time | < 3 ms |
| UPS connection in parallel | yes, with diode module uncoupled |
| UPS connection in series | no |
| Energy storage device connection in parallel | yes |
| Feedback voltage resistance | ≤ 35 V DC |
| Protection against overvoltage at the output (OVP) | < 30 V DC |
| Residual ripple | < 20 mV |
| Control deviation | < 0.4 % (change in load, static 10 % ... 90 %) |
| Control deviation | < 2.9 % (Dynamic load change 10 % ... 90 %, 10 Hz) |
| Control deviation | < 0.1 % (change in input voltage ±10 %) |
| Rise time | < 34 ms |
| Permissible backup fuse | B16 |
Mains operation
| Output Voltage | 24 V DC |
| Output voltage range | 24 V DC ... 28 V DC (> 24 V constant capacity) |
| Output current IN | 20 A |
| Dynamic Boost (IDyn.Boost) | 30 A |
| Maximum no-load power dissipation | < 4 W (230 V AC) |
| Power loss nominal load max. | < 50 W (230 V AC) |
Battery operation
| Output Voltage | UBAT -0.1 V DC |
| Output voltage range | 18 V DC ... 30 V DC |
| Output current IN | 20 A |
| Dynamic Boost (IDyn.Boost) | 30 A |
Signal Alarm
| Connection labeling | 3.2 |
| Signalization designation | Alarm |
| Type of signaling | LED red |
| Switching output | Transistor output, active |
| Output Voltage | 24 V DC |
| Continuous load current | 20 mA |
| LED status indicator | red |
Signal Battery mode
| Connection labeling | 3.3 |
| Signalization designation | Battery mode |
| Type of signaling | Yellow LED |
| Switching output | Transistor output, active |
| Output Voltage | 24 V DC |
| Continuous load current | 20 mA |
| LED status indicator | yellow |
Signal DC OK
| Connection labeling | 3.1 |
| Signalization designation | DC OK |
| Type of signaling | Green LED |
| Switching output | Transistor output, active |
| Output Voltage | 24 V DC |
| Continuous load current | 20 mA |
| LED status indicator | green |
Signal Ready
| Connection labeling | 3.4 |
| Signalization designation | Ready |
| Switching output | Transistor output, active |
| Output Voltage | 24 V DC |
| Continuous load current | 20 mA |
Energy storage
| Nominal voltage UN | 24 V DC |
| End-of-charge voltage | max. 30 V DC |
| Charging current (configurable) | 0.2 A ... 3 A (-25 °C ... 40 °C) |
| Charging current (Reduced) | 3 A ... 0 A (40 °C ... 65 °C) |
| Charging current (Preset) | 2.1 A (-25 °C ... 40 °C) |
| Charging current () | 3 A |
| Nominal capacity range | 4 Ah ... 40 Ah |
| Battery technology | VRLA-AGM |
| Charge characteristic curve | IU0U |
Conductor connection
| Connection Method | Push-in connection |
| rigid | 1 mm² ... 4 mm² |
| flexible | 1 mm² ... 2.5 mm² |
| flexible with ferrule without plastic sleeve | 1 mm² ... 2.5 mm² |
| flexible with ferrule with plastic sleeve | 1 mm² ... 1.5 mm² |
| AWG | 16 ... 12 |
| Stripping length | 10 mm |
| Connection Method | Push-in connection |
| rigid | 2.5 mm² ... 10 mm² |
| flexible | 2.5 mm² ... 6 mm² |
| flexible with ferrule without plastic sleeve | 2.5 mm² ... 6 mm² |
| flexible with ferrule with plastic sleeve | 2.5 mm² ... 4 mm² |
| AWG | 12 ... 8 |
| Stripping length | 15 mm |
| Connection Method | Push-in connection |
| rigid | 0.2 mm² ... 1.5 mm² |
| flexible | 0.2 mm² ... 1.5 mm² |
| flexible with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
| flexible with ferrule with plastic sleeve | 0.2 mm² ... 0.75 mm² |
| AWG | 24 ... 16 |
| Stripping length | 8 mm |
| Connection Method | Push-in connection |
| rigid | 2.5 mm² ... 10 mm² |
| flexible | 2.5 mm² ... 6 mm² |
| flexible with ferrule without plastic sleeve | 2.5 mm² ... 6 mm² |
| flexible with ferrule with plastic sleeve | 2.5 mm² ... 4 mm² |
| AWG | 12 ... 8 |
| Stripping length | 15 mm |
Interfaces
| Interface | USB (Modbus/RTU) |
| Number of interfaces | 1 |
| Connection Method | MINI-USB Type B |
| Locking | Screw |
Electrical properties
| Number of phases | 1.00 |
Product properties
| Product family | TRIO UPS |
| MTBF (IEC 61709, SN 29500) | 958219 h (25 °C) |
| MTBF (IEC 61709, SN 29500) | 576370 h (40 °C) |
| MTBF (IEC 61709, SN 29500) | 265724 h (60 °C) |
Insulation characteristics
| Protection class | I |
| Degree of pollution | 2 |
Item dimensions
| Width | 88 mm |
| Height | 130 mm |
| Depth | 160 mm |
Item dimensions with alternative mounting
| Width | 160 mm |
| Height | 130 mm |
| Depth | 88 mm |
Installation dimensions
| Installation distance right/left | 0 mm / 0 mm |
| Installation distance top/bottom | 50 mm / 50 mm |
Mounting
| Mounting Type | DIN rail mounting |
| Assembly note | alignable: horizontally 0 mm, vertically 50 mm |
| Mounting Position | horizontal DIN rail NS 35, EN 60715 |
Material specifications
| Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
| Hood version | PC |
| Side element version | Aluminum |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Ambient temperature (start-up type tested) | -40 °C |
| Maximum altitude | ≤ 4000 m (> 2000 m, observe derating) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at +25 °C, non-condensing) |
| Shock | 30g, 18 ms in accordance with IEC 60068-2-27 |
| Vibration (Operation) | < 12 ... 13.2 Hz, amplitude ±1 mm, 13.2 ... 100 Hz, 0.7gin accordance with IEC 60068-2-6 |
Overvoltage category
| EN 61010-1 | II |
Safety for measurement, control, and laboratory equipment
| Standard designation | Safety for equipment for measurement, control, and laboratory use |
| Standards/specifications | IEC 61010-1 |
Protective extra-low voltage
| Standard designation | Protective extra-low voltage |
| Standards/specifications | IEC 61010 (SELV) / (PELV) |
Safe isolation
| Standard designation | Safe isolation |
| Standards/specifications | DIN VDE 0100-410 |
Low-voltage power supplies, DC output
| Standard designation | Low-voltage power supplies, DC output |
| Standards/specifications | EN 61204-3 |
UL
| Identification | UL Listed UL 61010 |
| Identification | UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C |
EMC data
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| EMC requirements for noise emission | EN 61000-6-3 |
| EMC requirements for noise emission | EN 61000-6-4 |
| EMC requirements for noise immunity | EN 61000-6-1 |
| EMC requirements for noise immunity | EN 61000-6-2 |
| Noise immunity | Immunity in accordance with EN 61000-6-2 (industrial) |
| Conducted noise emission | EN 61000-6-3 |
| Noise emission | EN 61000-6-3 |
Harmonic currents
| Standards/regulations | EN 61000-3-2 |
Flicker
| Standards/regulations | EN 61000-3-3 |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 6 kV (Test Level 3) |
| Discharge in air | 8 kV (Test Level 3) |
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 |
| Frequency Range | 80 MHz ... 6 GHz |
| Test field strength | 10 V/m |
| Frequency Range | 1.4 GHz ... 6 GHz |
| Test field strength | 3 V/m |
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 |
| Input | 4 kV |
| Output | 2 kV |
| Signal | 2 kV |
Surge voltage load (surge)
| Standards/regulations | EN 61000-4-5 |
| Input | 1 kV (Test Level 3 - symmetrical) |
| Input | 2 kV (Test Level 3 - asymmetrical) |
| Output | 0.5 kV (Test Level 2 - symmetrical) |
| Output | 1 kV (Test Level 2 - asymmetrical) |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
Conducted interference
| Standards/regulations | EN 61000-4-6 |
| Frequency Range | 0.15 MHz ... 80 MHz |
| Voltage | 10 V |
Why Proax for Phoenix Contact 1105556?
Proax is an authorized distributor of Phoenix Contact 1105556 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
TRIO-PS/1AC/12DC/10, TRIO POWER power supplies with standard functionalityTRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.
TRIO-PS/1AC/5DC/10, TRIO POWER power supplies with standard functionalityTRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.