Official Distributor
SKU
MPN
TRIO-UPS-2G/1AC/24DC/5
Weight
0.958 kg
Series TRIO-UPS
TRIO-UPS-2G/1AC/24DC/5 - Uninterruptible power supply
TRIO UPS - UPS with integrated power supply, USB (Modbus/RTU), DIN rail mounting, Push-in connection, input: 1-phase, output: 24 V DC / 5 A
- Space saving: Combination of UPS module and power supply in the same housing
- Long buffer times, thanks to large selection of VRLA energy storage systems
- USB interface for connection to higher-level controllers such as industrial PCs
- Startup from energy storage possible, even without mains input
- Universal range of possible applications, thanks to a comprehensive package of approvals and an extended temperature range
- Easy installation, thanks to push-in connection technology
Technical Specifications
Input data
Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
Voltage type of supply voltage | AC |
Inrush Current | < 16 A |
Inrush current integral (I2t) | < 0.43 A2s |
Frequency range (fN) | 50 Hz ... 60 Hz (±10 %) |
Mains buffering time | ≥ 15 ms (120 V AC) |
Switch-on time | typ. 60 ms |
Typical current consumption | 3.3 A (100 V AC) |
Input fuse | 6.3 A (slow-blow, internal) |
Signal Bat.-Start
Connection labeling | 3.6 |
Signalization designation | Bat.-Start |
Low signal | Connection to SGnd with < 2.7 kΩ |
High signal | Open (> 200 kΩ between Bat.-Start and SGnd) |
Signal Remote
Connection labeling | 3.5 |
Signalization designation | Remote |
Low signal | Connection to SGnd with < 2.7 kΩ |
High signal | Open (> 35 kΩ between Remote and SGnd) |
Output data
Efficiency | typ. 85 % (120 V AC) |
Efficiency | typ. 87 % (230 V AC) |
Efficiency | typ. 96 % (Battery operation) |
Derating | > 60 °C (2.5%/K of POut nom.) |
Crest factor | 2.7 (120 V AC) |
Crest factor | 3.2 (230 V AC) |
Switch-over time | < 75 ms |
UPS connection in parallel | yes, with diode module uncoupled |
UPS connection in series | no |
Energy storage device connection in parallel | yes |
Feedback voltage resistance | ≤ 35 V DC |
Protection against overvoltage at the output (OVP) | < 30 V DC |
Residual ripple | < 20 mV |
Control deviation | < 0.75 % (change in load, static 10 % ... 90 %) |
Control deviation | < 1.25 % (Dynamic load change 10 % ... 90 %, 10 Hz) |
Control deviation | < 0.1 % (change in input voltage ±10 %) |
Rise time | < 15 ms |
Permissible backup fuse | B10 |
Mains operation
Output Voltage | 24 V DC |
Output voltage range | 24 V DC ... 28 V DC (> 24 V constant capacity) |
Output current IN | 5 A |
Dynamic Boost (IDyn.Boost) | 7.5 A |
Output power POUT (UN, IOUT = IN) | 120 W |
Maximum no-load power dissipation | < 3 W (230 V AC) |
Power loss nominal load max. | < 19 W (230 V AC) |
Battery operation
Output Voltage | UBAT -0.1 V DC |
Output voltage range | 18 V DC ... 30 V DC |
Output current IN | 5 A |
Signal Alarm
Connection labeling | 3.2 |
Signalization designation | Alarm |
Type of signaling | LED red |
Switching output | Transistor output, active |
Output Voltage | 24 V DC |
Continuous load current | 20 mA |
LED status indicator | red |
Signal Battery mode
Connection labeling | 3.3 |
Signalization designation | Battery mode |
Type of signaling | Yellow LED |
Switching output | Transistor output, active |
Output Voltage | 24 V DC |
Continuous load current | 20 mA |
LED status indicator | yellow |
Signal DC OK
Connection labeling | 3.1 |
Signalization designation | DC OK |
Type of signaling | Green LED |
Switching output | Transistor output, active |
Output Voltage | 24 V DC |
Continuous load current | 20 mA |
LED status indicator | green |
Signal Ready
Connection labeling | 3.4 |
Signalization designation | Ready |
Switching output | Transistor output, active |
Output Voltage | 24 V DC |
Continuous load current | 20 mA |
Signal supply 24 V DC, 20 mA, SGnd
Connection labeling | 3.7 |
Energy storage
Nominal voltage UN | 24 V DC |
End-of-charge voltage | max. 30 V DC |
Charging current (configurable) | 0.2 A ... 1.5 A (-25 °C ... 40 °C) |
Charging current (Reduced) | 1.5 A ... 0 A (40 °C ... 65 °C) |
Charging current (Preset) | 1.2 A (-25 °C ... 40 °C) |
Charging current () | 1.5 A |
Nominal capacity range | 1.2 Ah ... 12 Ah |
Battery technology | VRLA-AGM |
Charge characteristic curve | IU0U |
Conductor connection
Connection Method | Push-in connection |
rigid | 0.2 mm² ... 4 mm² |
flexible | 0.2 mm² ... 2.5 mm² |
flexible with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
flexible with ferrule with plastic sleeve | 0.25 mm² ... 1.5 mm² |
rigid (AWG) | 24 ... 12 |
Stripping length | 10 mm |
Connection Method | Push-in connection |
rigid | 0.2 mm² ... 4 mm² |
flexible | 0.2 mm² ... 2.5 mm² |
flexible with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
flexible with ferrule with plastic sleeve | 0.25 mm² ... 1.5 mm² |
rigid (AWG) | 24 ... 12 |
Stripping length | 10 mm |
Connection Method | Push-in connection |
rigid | 0.2 mm² ... 1.5 mm² |
flexible | 0.2 mm² ... 1.5 mm² |
flexible with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
flexible with ferrule with plastic sleeve | 0.2 mm² ... 0.75 mm² |
rigid (AWG) | 24 ... 16 |
Stripping length | 8 mm |
Connection Method | Push-in connection |
rigid | 0.2 mm² ... 10 mm² |
flexible | 0.2 mm² ... 6 mm² |
flexible with ferrule without plastic sleeve | 0.25 mm² ... 6 mm² |
flexible with ferrule with plastic sleeve | 0.25 mm² ... 4 mm² |
rigid (AWG) | 24 ... 8 |
Stripping length | 15 mm |
Interfaces
Interface | USB (Modbus/RTU) |
Number of interfaces | 1 |
Connection Method | MINI-USB Type B |
Locking | Screw |
Electrical properties
Number of phases | 1.00 |
Insulation voltage input/output | 3 kV AC (type test) |
Insulation voltage input/output | 1.5 kV AC (routine test) |
Insulation voltage output / PE | 500 V AC (type test) |
Insulation voltage output / PE | 500 V AC (routine test) |
Insulation voltage input / PE | 1.5 kV AC (type test) |
Insulation voltage input / PE | 1.5 kV AC (routine test) |
Product properties
Product family | TRIO UPS |
MTBF (IEC 61709, SN 29500) | > 1395470 h (230 V AC, at 25 °C) |
MTBF (IEC 61709, SN 29500) | > 825726 h (230 V AC, at 40 °C) |
MTBF (IEC 61709, SN 29500) | > 388314 h (230 V AC, at 60 °C) |
Insulation characteristics
Protection class | I |
Degree of pollution | 2 |
Life expectancy (electrolytic capacitors)
Current | 5 A |
Temperature | 40 °C |
Additional text | 230 V AC |
Item dimensions
Width | 60 mm |
Height | 130 mm |
Depth | 60 mm |
Installation dimensions
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
Mounting Position | horizontal DIN rail NS 35, EN 60715 |
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
Housing Material | Metal |
Hood version | PC |
Side element version | Aluminum |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Ambient temperature (start-up type tested) | -40 °C |
Maximum altitude | ≤ 4000 m (> 2000 m, observe derating) |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (At +25°C, non-condensing) |
Shock | 30g, 18 ms in accordance with IEC 60068-2-27 |
Vibration (Operation) | < 12 ... 13.2 Hz, amplitude ±1 mm, 13.2 ... 100 Hz, 0.7gin accordance with IEC 60068-2-6 |
Overvoltage category
EN 61010-1 | II |
Safety for measurement, control, and laboratory equipment
Standard designation | Safety for equipment for measurement, control, and laboratory use |
Standards/specifications | IEC 61010-1 |
Protective extra-low voltage
Standard designation | Protective extra-low voltage |
Standards/specifications | IEC 61010 (SELV) / (PELV) |
Safe isolation
Standard designation | Safe isolation |
Standards/specifications | DIN VDE 0100-410 |
Low-voltage power supplies, DC output
Standard designation | Low-voltage power supplies, DC output |
Standards/specifications | EN 61204-3 |
Ship’s bridge
Standard designation | Ship’s bridge |
Standards/specifications | IEC/EN 60945 |
UL
Identification | UL Listed UL 61010 |
Identification | UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C |
Shipbuilding
Identification | DNV |
Identification | LR |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
Noise immunity | Immunity in accordance with EN 61000-6-2 (industrial) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conducted noise emission | EN 61000-6-3 |
Noise emission | EN 61000-6-3 |
DNV GL conducted interference | Class B |
Additional text | Area power distribution |
DNV GL noise radiation | Class B |
Additional text | Bridge and deck area |
Harmonic currents
Standards/regulations | EN 61000-3-2 |
Flicker
Standards/regulations | EN 61000-3-3 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 3) |
Discharge in air | 8 kV (Test Level 3) |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 6 GHz |
Test field strength | 10 V/m |
Frequency Range | 1.4 GHz ... 6 GHz |
Test field strength | 3 V/m |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 4 kV |
Output | 2 kV |
Signal | 2 kV |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 1 kV (Test Level 3 - symmetrical) |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 0.5 kV (Test Level 2 - symmetrical) |
Output | 1 kV (Test Level 2 - asymmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 0.15 MHz ... 80 MHz |
Voltage | 10 V |
Accessories
Why Proax for Phoenix Contact 2907160?
Proax is an authorized distributor of Phoenix Contact 2907160 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- TRIO-PS/1AC/12DC/10, TRIO POWER power supplies with standard functionalityTRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.
- TRIO-PS/1AC/5DC/10, TRIO POWER power supplies with standard functionalityTRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.